150 KVA Mai Canjawa Akwatin Lantarki-22.8 / 0.48 KV|Amurka 2025

150 KVA Mai Canjawa Akwatin Lantarki-22.8 / 0.48 KV|Amurka 2025

Ƙasar Bayarwa: Amurka 2025
Yawan aiki: 150 kVA
Wutar lantarki: 22.8/0.480 kV
Feature: DOE inganci
Aika Aikace-aikacen

Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'antun da masu samar da akwatin lantarki 150 kva -22.8/0.48 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

 

image003001

Akwatin wutar lantarki na 150 kVA yana ba da ƙarancin ƙarfi, abin dogaro, da ingantaccen ƙarfi don tsarin rarraba taimako.

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

A matsayin wani ɓangare na wannan aikin samar da kayan aikin lantarki na Amurka wanda aka kawo a cikin 2025, abokin ciniki ya kuma ba da umarnin 150 kVA mai ɗaukar wutan lantarki da aka ƙera don tallafawa nauyin wutar lantarki a cikin tsarin rarrabawa, yana ba da canjin wutar lantarki a cikin gida yayin da yake ci gaba da dacewa da matsakaicin matsakaici{2}} ƙarfin lantarki wanda babban gidan wuta ya kawo.

A cikin wannan aikin, abokin ciniki kuma ya shigar da wani 2660 kVA 22.8/0.8 KV uku lokaci kushin da aka saka tasfo a matsayin rukunin jujjuyawar wutar lantarki na farko, alhakin sarrafa babban nauyin rarraba kayan aikin (duba yanayin aikin da ya danganci: 2660 kVA akwatin wuta na waje). Ƙungiyar 150 kVA don haka tana aiki azaman ƙarin akwatin wutan lantarki bayani, yana ba da ingantaccen canjin wutar lantarki don ƙananan kayan lantarki kamar tsarin sarrafawa, sabis na kayan aiki, da kayan taimako.

An ƙididdige wutar lantarki 150 kVA, tare da babban ƙarfin lantarki na 22.8 kV da ƙarfin lantarki na biyu na 0.48 kV. Yana amfani da ƙungiyar vector Dyn1, wanda ke ba da halaye masu dacewa na ƙasa da alaƙar lokacin wutar lantarki da ake buƙata don ingantaccen aiki tsakanin tsarin rarraba lokaci uku-.

Ko da yake ƙarfin wutar lantarki yana da ƙanƙanta, an ƙirƙira shi daidai da IEEE Std C57.12.34-2022, yana tabbatar da cewa wannan ƙaramin kushin{2} da aka ɗora tasfoma ya dace daidai da ƙa'idodin aminci da aiki kamar manyan na'urori masu rarraba wutar lantarki da ake amfani da su a cikin cibiyoyin sadarwa na matsakaicin ƙarfin lantarki.

 

 

 

1.2 Ƙayyadaddun Fasaha

150kVA uku lokaci kushin saka transformerbayani dalla-dalla da takardar bayanan

Isarwa zuwa
Amurka
Shekara
2025
Nau'in
Uku fanni kushin Dutsen transformer
Daidaitawa
IEEE Std C57.12.34-2022
Ƙarfin Ƙarfi
150 KVA
Yawanci
60HZ
Ciyarwa
Madauki
Gaba
Matattu
Mataki
uku
Nau'in Sanyi
KNAN
Liquid insulant
Farashin FR3
Babban Voltage
22.8 kV
Na biyu Voltage
0.48 kV
Ƙungiyar Vector
Dyn1
Abubuwan Iska
Aluminum
Impedance
3.5%
inganci
DOE
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
0.373 kV
Akan Rasa Load
1.163 kV
Na'urorin haɗi
Garkuwar ƙasa

 

1.3 Zane

2500kVA uku lokaci kushin saka transformer zane da sunan farantin

2660 kva outdoor transformer box-outline-drawing 2660 kva outdoor transformer box-nameplate

 

 

02 Masana'antu

2.1 Uku -Mataki na Uku{2}} Ƙirar Ƙira

2660 kva outdoor transformer box-electrical-steel-core

Transformer ya ɗauki nau'in magnetic core guda uku - mataki na uku{1}} da aka yi daga sanyi{2}} hatsin da aka yi birgima{3}}madaidaicin silikon karfe laminations. Daidaitaccen tari yana rage hasara mai mahimmanci, girgizawa, da hayaniya yayin haɓaka aiki yayin ci gaba da aiki. Tsayayyen rarrabawar maganadisu yana da mahimmanci don dogon lokaci- amintacce na akwatin wutan lantarki da ke aiki a matsakaici{7}}tsarin rarraba wutar lantarki.

 

2.2 Aluminum Winding System

Tsarin iska yana amfani da madugu na aluminium tare da maɗaukakin zafin jiki, wanda aka tsara don 22.8 kV / 0.48 kV canjin wutar lantarki. Aluminum windings yana ba da kyakkyawar ma'auni na ɗabi'a, ƙarfi, da nauyi-wanda ya dace da ƙaramin akwatin wutan lantarki a cikin kundi{5}}waɗanda aka ɗora. Sarrafa injina da ƙarfafa injina suna haɓaka amincin rufi da juriya ga gajerun rundunonin kewayawa.

 

2.3 FR3 Tsarin Kulawa da Sanyaya

Mai juyawa yana amfani da ruwa mai hana ruwa na ester na halitta na FR3, yana ba da mafi girman amincin wuta da mafi kyawun haƙuri fiye da mai ma'adinai. Hanyar sanyaya ta KNAN ta dogara ne akan zagayawan mai na halitta da sanyaya iska ta yanayi don kiyaye yanayin zafin aiki. Amintaccen sanyaya yana da mahimmanci. Hatta ga kananan tafofi.

2660 kva outdoor transformer box-activepart

 

2.4 Tankin Mai Canjawa

2660 kva outdoor transformer box-tank-body

Transformer yana ɗaukar ƙaramin kumfa{0}madaidaicin tsarin shinge, yana samar da akwatin wutan lantarki wanda ya haɗu da kayan aikin wuta, kayan aikin sauya sheka, da na'urorin kariya a cikin amintaccen shinge na waje wanda ya dace da kayan aiki ko shigarwa masana'antu.

Karamin kushin da aka ɗora wutar lantarki yana amfani da mataccen ƙira ta gaba, wanda ke ba da kariya ga ma'aikatan kulawa ta hanyar hana hulɗar haɗari tare da sassa masu ƙarfi yayin aiki da sabis.

Har ila yau, ƙulli yana goyan bayan daidaitawar ciyarwar madauki, yana ba da damar shigar da mai canzawa a cikin tsarin rarraba zobe inda ake buƙatar ci gaba da wutar lantarki da daidaitawar hanyar sadarwa.

Duk da ƙaramin ƙarfinsa, an gina tafsirin don samar da daidaitattun ƙa'idodi iri ɗaya da ake tsammanin daga manyan kayan aikin rarraba lokaci uku.
Ƙananan girma.

 

2.5 Kariya da Kulawa

Mai sauya fasalin ya ƙunshi mahimman kayan aikin sa ido waɗanda ke ba masu aiki damar bin yanayin ciki yayin aiki.

Na'urar Kulawa

Aiki

Matsayin Matsayin Mai

Yana nuna matakin mai

Ma'aunin Yanayin Mai

Yana lura da yanayin aiki

Ma'aunin Matsalar Tanki

Yana gano matsi mara kyau

Valve Taimakon Matsi

Yana kare mutuncin tanki

Ƙarin abubuwan kariya sun haɗa da:
• Garkuwar electrostatic ta ƙasa
• Kariyar fuse
• Hudu - maɓalli na ɗaukar nauyi
Waɗannan abubuwan haɗin gwiwar suna ba da damar akwatin wutan lantarki don amsa lami lafiya ga kurakuran lantarki da yanayin aiki mara kyau.
Ganin aiki yana da mahimmanci.
Hatta ga kananan tafofi.

2660 kVA outdoor pad-mounted-transformer-protection-and-monitoring-devices

 

 

03 Gwaji

2660 kVA outdoor transformer box test standards

Sakamakon Gwaji

2660 kVA outdoor transformer box test results

 

2660 kva outdoor transformer box-testing
2660 kva outdoor transformer box-electrical-test

 

 

04 Shiryawa da sufuri

2660 kva outdoor transformer box-packaging
2660 kva outdoor transformer box-export-packing

 

 

05 Yanar Gizo da Takaitawa

2660 kva outdoor transformer box-right-45-degree-view

A cikin kayan aikin gabaɗaya, akwatin lantarki na 150 kVA na wutar lantarki yana aiki tare da babban akwatin gidan wuta na 2660 kVA na waje, yana samar da tsarin rarraba wutar lantarki mai daidaitawa wanda babban injin ɗin ke ɗaukar mafi yawan nauyin wutar lantarki, yayin da ƙaramin rukunin ke ba da wutar lantarki na gida don tsarin taimako da kayan sabis a duk faɗin wurin.

Babban gidan wuta yana sarrafa jujjuyawar wutar lantarki.

Ƙananan naúrar tana goyan bayan lodin taimako.

Tare, waɗannan na'urorin lantarki na akwatin na'ura mai canzawa suna ƙirƙirar matsakaicin matsakaici{0}}tsarin rarraba wutar lantarki mai iya tallafawa ci gaba da aiki tare da ba da damar rarraba wutar lantarki a cikin aikin.

 

 