Menene Wutar Lantarki

 

 

What is an Electrical Substation

Mabuɗin Ayyukan Wutar Lantarki

Canjin Wutar Lantarki da Rarraba Wuta

Rukunin tashoshin suna ɗaukar matakan ƙarfin lantarki sama ko ƙasa don tabbatar da ingantaccen watsa wutar lantarki akan nesa mai nisa da amintaccen rarraba zuwa ƙarshen masu amfani, rage asarar makamashi a duk hanyar sadarwar.

Kariya da Kula da Kayan Wutar Lantarki

Ta hanyar relays na kariya, masu watsewar da'ira, da tsarin sarrafawa, tashoshin sadarwa suna gano kurakurai, keɓe ɓangarori marasa kyau, da kiyaye mahimman kayan aiki don kiyaye kwanciyar hankali na tsarin da amincin aiki.

Kulawa, Automation, da Haɗin Tsarin (SCADA)

Rukunin tashoshin zamani suna sanye take da tsarin sa ido da sadarwa waɗanda ke ba da damar samun bayanan lokaci na gaske, sarrafa nesa, da haɗin kai tare da dandamali na SCADA, haɓaka ingantaccen aiki da amincin grid.

 

 

Nau'in Canji na Substation

 

 

  • Muna ba da cikakkiyar mafita ta hanyar sadarwa - daga ra'ayi zuwa ƙaddamarwa - don biyan buƙatu mai girma na abin dogaro, aminci, da ingantaccen rarraba wutar lantarki.
  • Ko na kayan aiki, masu amfani da masana'antu, tsire-tsire masu sabuntawa, ko hanyoyin sadarwa, muna isar da tsarin maɓalli waɗanda suka dace da IEC, IEEE, ANSI, CSA da ƙa'idodin amfanin yanki.
  • Kowane nau'in tashar tashar za a iya keɓance shi tare da matakan ƙarfin lantarki da ake buƙata, iyakoki, da daidaitawa don saduwa da ƙa'idodin gida da yanayin aikin.

 

  • Rukunin Substation
    Transformer
  • Karamin Substation
    Transformer
  • Rukunin Rukunin Ruwa
    Transformer
  • Mota{0}}wayar hannu
    Transformer na substation

Naúrar Substation Transformer

Naúrar tashar wutar lantarki shine pre{0}}wanda aka haɗe, ƙaƙƙarfan naúrar rarraba wutar lantarki wanda ke sauke matsakaicin{1}}ƙarar wutar lantarki zuwa amintaccen ƙarfin lantarki mai amfani. Ƙirar ta kusa- haɗe-haɗe yana haɗa tafsirin tare da firamare na farko da na biyu kusa da lodi, rage girman cabling da tsayin bas, rage asarar wuta, inganta tsarin wutar lantarki, da haɓaka amincin sabis.

  • Har zuwa 10 MVA 34.5 kV
  • Ƙarfin ƙima har zuwa 10 MVA
  • Matsakaicin matakin rufewa har zuwa 161 kV
  • Hawan zafin jiki: 55 digiri, digiri 65, digiri 55/65, digiri 45

Siffofin Musamman

  • Kariyar lantarki don rage tsangwama.
  • Babban{0}}kariyar ruɓar shinge (C5{2}}M, marine/masana'antu) da ƙira mai jure yanayin ƙasa.
  • Matsayin bushing na al'ada da wayoyi (shigarwa na sama/gefe, buɗewa na musamman).
  • Saurin shigar da ƙira tare da buɗewar fan, wuraren ɗagawa, da tashoshi na ƙasa mai sauri.
  • Ƙirar ƙira mai ƙaranci{0} bisa ga bukatun abokin ciniki.
  • Ƙwarewa ta musamman, haƙuri, da K{0} ƙira masu ƙira don ingantattun jituwa da sarrafa kaya marasa kan layi.
  • Yana goyan bayan nau'in ruwa{0}}cike, bushe{1}}, da ƙirar canji na musamman don takamaiman aikace-aikace
Unit Substation Transformer

Karamin Substation Transformer

Karamin tashar, wanda kuma aka sani da prefabricated substation, masana'anta ce -haɗe, cikakken ruɓaɓɓen na'ura mai rarraba wutar lantarki wanda ke haɗa manyan maɓallan wutar lantarki, taranfoma, da ƙananan{2} na'urorin wutar lantarki zuwa ƙaramin tsari guda ɗaya. An tsara shi don ingantaccen canji da rarraba wutar lantarki, yana da fasalin ƙaƙƙarfan shinge na ƙarfe tare da kariya da yawa, yana sa ya dace da shigarwa na ciki da waje a cikin gidaje, kasuwanci, da aikace-aikacen masana'antu.

  • Har zuwa 20000 KVA 72 kV
  • Ƙarfin Transformer Kasa da ko daidai da 20000 KVA
  • Ƙarfin wutar lantarki: 12 - 72 kV
  • Matakan kariya na yadi: IP54
  • Matsakaicin tsayi: mita 5000
  • Tsarin sa ido na bango yana ba da damar sa ido na ainihi{0} na mahimman mahimman bayanai, gami da zafin jiki na farko, fitarwa na ɓarna, da hasken baka.
  • Ana ɗaukar tsare-tsaren rufewa iri-iri, kamar surufin iskar gas mai dacewa da muhalli, rufin iska, daɗaɗɗen insulation, da ƙaramin rufewa.
Compact Substation Transformer

Canja-canje na Rukunin Rukunin Rubutun

Na'urar taransifomar da ke cikin kwantena ita ce rigar - haɗe, rukunin rarraba wutar lantarki na zamani wanda ke da matsakaici{1}} da ƙananan -arfin wutar lantarki, tasfoma, da kayan taimako a cikin kwandon ƙarfe mai ɗorewa. An ƙera shi don turawa cikin sauri, sauƙin jigilar kaya, da shigarwar maɓalli, yana samar da abin dogaro, yanayi{4}maganin wutar lantarki don rukunoni na wucin gadi, kayan aiki na waje, ayyukan masana'antu, da aikace-aikace masu mahimmanci-.

  • Har zuwa 600000kVA 7550kV
  • Ƙarfin wutar lantarki: 12 - 550 kV
  • Matsakaicin matsakaicin ɗan gajeren lokaci - jure halin yanzu: 63 kA;
  • Matsayin kariya: IP55

Siffofin Musamman

  • Nau'in tsarin akwatin sun haɗa da: tsarin gidan da aka riga aka tsara, daidaitaccen tsarin kwantena;
  • Girman ganga na zamani (10'-40' ISO) don buƙatun rukunin yanar gizo daban-daban.
  • Zaɓuɓɓukan ƙira-hujja na ciki don ingantaccen aminci.
  • Kariyar walƙiya, hasken gaggawa, ƙararrawa, da na'urorin tsaro.
  • Solar PV mataki-up tashoshin tare da hadedde inverter/DC aka gyara.
  • Zaɓuɓɓuka don sarrafa grid, saka idanu mai nisa, da haɗin SCADA
  • Zaɓuɓɓukan simintin simintin gyare-gyare, mai cike da mai, ko zaɓin masu canza iska dangane da buƙatun aikin.
Containerized Substation Transformer

Mota{0}}Mai Taswirar Taswirar Mota

Motar {{0}wayar da aka ɗora tafsirin wayar hannu tirela ce- ko chassis{2}}wanda aka ɗora tashar wayar hannu wacce ke haɗa babban taswirar wutar lantarki, MV/LV switchgear, na'urorin kariya, da tsarin taimako zuwa raka'a ɗaya. An tsara shi don ƙaddamarwa da sauri da aiki na waje, yana ba da sassaucin ra'ayi, abin dogara ga hanyoyin wutar lantarki na wucin gadi don gaggawa, kulawa, da aikace-aikacen yanar gizo mai nisa.

  • Har zuwa 240000kVA 330 kV
  • Ƙarfin wutar lantarki: 12 - 330 kV
  • Matsakaicin matsakaicin ɗan gajeren lokaci - jure halin yanzu: 63 kA;
  • Kulawa da hankali da sarrafawa - ginannun a cikin SCADA/tsarin sa ido na nesa don sigogin lokaci na ainihi (voltage, halin yanzu, zafin jiki) da sarrafawa mai nisa.
  • Babban kariyar muhalli - IP55-ƙididdiga masu ƙima, zaɓuɓɓukan daɗaɗɗa da lalata-juriya don mahalli masu tsauri (ƙananan zafi, guguwar yashi, yankunan bakin teku).
Vehicle-mounted mobile substation Transformer

 

 

Ayyukan da Muke bayarwa

 

 

electrical substation services we offer

 

Muna ba da mafita na tashar wutar lantarki, tun daga tuntuba da samar da kayan aiki zuwa shigarwa, ƙaddamarwa, horo, da tallafin tallace-tallace bayan{0}. Ƙwararrun ƙwararrun mu suna tabbatar da amintaccen aiki, ingantaccen aiki da cikakken tallafin rayuwa don babban aikin rarraba wutar lantarki{2}.

 

 

Me Yasa Zabe Mu

 

 

Ƙwararrun Substation Tabbatacciyar

Tare da shekaru da yawa na haɗe-haɗe gwaninta, injiniyoyinmu, injiniyoyi, da masu tarawa sun ƙware a ƙira da kera na'urorin taswirar wutar lantarki. An gina kowane rukunin tare da dogaro a ainihin sa, yana rage raguwar lokaci da tabbatar da isar da wutar lantarki ga abubuwan amfani, cibiyoyin bayanai, da tsarin rarraba masana'antu a duk duniya.

Proven Substation Expertise
An tsara shi zuwa Matsayin Duniya

An ƙirƙira su, ƙera su, kuma an gwada su cikin cikakken aiki tare da manyan ƙa'idodi na duniya, gami da ANSI, IEEE, NEMA, DOE, UL & cUL Listed, CSA, da buƙatun IEC. Ana tura samfuranmu a cikin 50+ asashe, suna biyan sharuɗɗan grid iri-iri da buƙatun tsari.

Designed to Global Standards
Aikace-aikacen -Kwararren Ƙwararru

Muna ba da gyare-gyare mai yawa don dacewa da ƙayyadaddun buƙatun tashar sadarwa{0}}ma'auni na lantarki, sarrafa ma'auni, aminci{1}}madaidaicin shimfidu, da baka{2}} rage haɗarin walƙiya. Hakanan ana samun hanyoyin samar da wutar lantarki ta wayar hannu don amsa gaggawa da buƙatun wutar lantarki na ɗan lokaci.

Application-Driven Customization
Cikakken Jarabawa, Cikakkun Bayyanawa

Kowane taswira yana fuskantar cikakkiyar gwajin masana'anta akan ma'aunin ANSI/IEEE, IEC, DOE, da CSA. Rubutun gwaji na musamman da Gwajin Shaidar Masana'antu{1}akan -shafi ko ta hanyar taron bidiyo{3}} tabbatar da cikakken tabbacin aiki kafin bayarwa.

Fully Tested, Fully Transparent

 

page-1-1

 

Ba Tabbacin Abin Da Ya Kamace Ku?
Injiniyoyin lantarki na mu na iya jagorantar ku zuwa ingantaccen bayani don buƙatun aikin ku.

 

 

Maganar Ayyuka

 

 

1000/1150 kVA Distribution Transformer Substation-13.8/0.48 kV | USA 2025

1000/1150 kVA Rarraba Mai Canja wurin Mai Rarraba-13.8 / 0.48 kV|Amurka 2025

Kasar: Amurka 2025
Yawan aiki: 1000/1150 kVA
Voltage: 13.8-0.48GrdY/0.277kV
Feature: with FR3 oil and CT
Kara karantawa
7

1600 kVA Compact Substation Transformer-33/0.4 kV|Habasha 2022

Kasar: Ethiopia 2022
Yawan aiki: 1600kVA
Ƙarfin wutar lantarki: 33/0.4kV
Feature: Multifunctional man matakin ma'auni
Kara karantawa
8

3000 kVA Wutar Lantarki-44 / 0.6 kV|Kanada 2025

Kasar: Kanada 2025
Yawan aiki: 3000 kVA
Wutar lantarki: 44-0.6GrdY/0.347 kV
Siffar: tare da tamper{0}}akwatin hujja
Kara karantawa
9

2000/2300kVA Mai Rarraba Wutar Lantarki-13.8/0.48 kV|Amurka 2025

Kasar: Amurka 2025
Yawan aiki: 2000/2300 kVA
Wutar lantarki: 13.8-0.48GrdY/0.277kV
Feature: tare da FR3 mai da CT
Kara karantawa
10

2000 kVA Rarraba Mai Canja wurin Rarraba-44 / 0.48 kV|Kanada 2025

Ƙasar Bayarwa: Kanada 2025
Yawan aiki: 2000 kVA
Ƙarfin wutar lantarki: 44-0.48 / 0.277 kV
Feature: tare da akwatin marshalling
Kara karantawa
11

3750/4250 kVA Mai Rarraba Mai Canjawa-13.8 / 0.48 kV|Amurka 2025

Kasar: Amurka 2025
Yawan aiki: 3750/4250 kVA
Wutar lantarki: 13.8-0.48/0.277kV
Siffar: tare da mai FR3
Kara karantawa

 

 

FAQ

 

 

Tambaya: Wadanne ka'idoji na kasa da kasa suke aiki da su tafsoshin ku?

A: An ƙera, ƙera su, kuma an gwada su don dacewa da ANSI/IEEE C57, NEMA, DOE, IEC, CSA, da UL®, kamar yadda ya dace. Kowace naúrar ta cika ko ƙetare ƙa'idodi masu dacewa da buƙatun aiki don amfanin duniya da aikace-aikacen masana'antu.

Tambaya: Wane gwajin masana'anta ake yi kafin bayarwa?

A: Kowane transfoma yana fuskantar cikakkiyar gwajin masana'anta daidai da ka'idojin da suka dace. Ana iya keɓance shirye-shiryen gwaji bisa ga buƙatun aikin, kuma ana samun Gwajin Shaidar Factory (FAT) ko dai akan - ko ta hanyar taron tattaunawa na bidiyo mai aminci.

Tambaya: Bayan{0}} tallace-tallace da tallafin fasaha kuke bayarwa?

A: Muna ba da cikakkun takaddun fasaha, rahotannin gwajin masana'anta, jagorar shigarwa, da ci gaba da goyan bayan aikin injiniya don tabbatar da aiwatar da aiki mai santsi, ingantaccen aiki, da kuma tsawon lokaci{0}aiki a tsawon rayuwar sabis na taswira.

Tambaya: Shin kuna samar da hanyoyin samar da wutar lantarki ta hannu?

A: iya. Muna ba da mafita ta wayar hannu da na wucin gadi wanda aka ƙera don amsa gaggawa, ƙarewar kiyayewa, da turawa cikin sauri, samar da ingantaccen wutar lantarki lokacin da ba a samu tashoshi na dindindin ba.

Tambaya: Shin za a iya inganta tashoshin wutar lantarki da sabuwar fasaha?

A: iya. Za'a iya haɓaka tashoshi masu canzawa tare da mafi girma{1}} na'urori masu canzawa, ingantaccen tsarin sa ido, da fasahar grid mai wayo don haɓaka aiki, dogaro, da daidaitawa ga buƙatun grid na gaba.

 

 

Abubuwan da ke da alaƙa

 

 

 

 

Nemi Quote don Maganin Substation na ku

Da fatan za a cika fom ɗin, kuma ɗaya daga cikin membobin ƙungiyarmu zai tuntuɓar ku cikin sa'o'i 24.

 

 