500 KVA Mai Rarraba Masu Haɗawa-12.47 / 0.48 KV|Amurka 2025
Yawan aiki: 500kVA
Wutar lantarki: 12.47GrdY/7.2-0.48Y/0.277 kV
Feature: Core tare da karewa mai tushe
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'antun da masu samar da 500 kva na'ura mai ɗaukar wutan lantarki{6}}12.47/0.48 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Isar da Wuta, Tsare sarari. Mai Canjawa Mai Canjin Smart Pad.
01 Gabaɗaya
1.1 Bayanin Aikin
500 kVA uku fanti pad mounted transformer aka kai Amurka a 2025. Ƙididdiga ikon na'urar shine 500 kVA tare da KNAN sanyaya. Babban ƙarfin lantarki shine 12.47GrdY / 7.2 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.48Y / 0.277 kV, sun kafa ƙungiyar vector na YNyn0.
Wannan tashar tasha ta -nau'i, uku{1}}lokaci, biyar{2}}aramin kafa -wanda aka ɗora tasfoma an ƙera shi don ingantaccen aminci da aiki a buƙatar aikace-aikacen rarraba wutar lantarki. An ƙera shi tare da ƙimar 600A mai girma na yanzu a kan babban gefen ƙarfin lantarki, yana tabbatar da isar da wutar lantarki mai ƙarfi da kwanciyar hankali na cibiyar sadarwa.
Tushen gininsa yana da ingancin iskar tagulla mai inganci{0} don ingantaccen aiki da inganci, wanda aka nitse cikin ruwa mai ƙima na FR3®. Wannan ci-gaba, mai dielectric mai ba da dadewa yana ba da kariya ta musamman ta wuta, haɓakar dogon rayuwa, da ingantaccen sarrafa zafi idan aka kwatanta da mai na ma'adinai na gargajiya.
Maɓalli mai mahimmancin ƙira shine amincin aiki da kariya. Dukansu manyan nau'ikan wutar lantarki- da ƙanana{2} ana sanye su da kafaffen garkuwar wutan lantarki, yadda ya kamata suna rage haɗarin igiyoyin wutar lantarki na wucin gadi da tabbatar da tsaftataccen wutar lantarki.
Don ci gaba da sa ido da tsaro na aiki, injin tafsiri yana sanye da cikakkiyar ma'auni na daidaitattun ma'auni: alamar matakin ruwa, mai nuna zafin iska, da ma'aunin injin / matsa lamba. An ƙara ma'aunin injin / matsa lamba tare da daidaitawar adireshi don samar da ƙararrawa na ainihi{1}} don yanayin matsatsi mai mahimmanci, yana ba da damar kiyayewa da tsarin kariya.
Haɗa kayan ɗorewa, fasahar ruwa mai ƙima, ƙaƙƙarfan fasalulluka masu aminci, da ingantattun kayan aiki, wannan kumfa{0}madaidaicin taswira yana isar da ingantaccen, amintaccen, kuma dogon{1} bayani mai dorewa don tsarin rarraba ƙasa na zamani.
1.2 Ƙayyadaddun Fasaha
500 kVA kushin da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
IEEE Std C57.12.34-2022 DOE 2016
|
|
Ƙarfin Ƙarfi
500 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Radial
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
KNAN
|
|
Babban Voltage
12.47GrdY/7.2kV
|
|
Na biyu Voltage
0.48Y/0.277 kV
|
|
Abubuwan Iska
Copper
|
|
Ƙungiyar Vector
YNyn0
|
|
Impedance
5.75%
|
|
inganci
99.35%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
0.65 kW
|
|
Akan Rasa Load
4.36 kW
|
1.3 Zane
500 kVA kushin da aka ɗora zane da girma.
![]() |
![]() |
02 Masana'antu
2.1 Kori

An gina ainihin mashin hawa na taswirori daga babban{0}}maki, ƙarami{1}}arancin laminations na ƙarfe na lantarki, daidai da tara kuma an manne amintacce don samar da ƙaƙƙarfan lokaci guda uku-, biyar- magnetic circuit. Mahimmanci, garkuwar ƙasa na electrostatic - yawanci foil ɗin tagulla{6} ana sanya shi gaba ɗaya tsakanin cibiya da ƙananan iskar wutar lantarki-. Wannan garkuwar tana haɗe da amintaccen tashar wutar lantarki, ta samar da ƙayyadadden hanyar zuwa ƙasa. Babban aikinsa shi ne don karkatar da maɗaukakiyar mitoci masu ƙarfi da ƙarfi da ƙarfi da ƙararrawar yanayi na gama gari daga iska, don haka kare rufi, rage damuwa na lantarki, da rage yaduwar kutse na lantarki cikin tsarin rarraba na biyu.
2.2 Ciyarwar Radial
Matakan hawa na'ura mai canzawa a cikin daidaitaccen ciyarwar radial na tasha yana aiki azaman wurin rarrabawa na ƙarshe a cikin hanyar sadarwar wutar lantarki, yana karɓar wuta daga tushe guda ɗaya na sama. Tashoshin ta na farko suna haɗa kai tsaye zuwa mai ciyarwa ta tsakiya, suna raguwar ƙarfin wutar lantarki don lodin ƙasa ta hanyar fitowar sakandare. A matsayin sigar tasha, tana gaji tsarin dogaro guda ɗaya -: kuskure ko kashewa zai tarwatsa wutar lantarki ga na'urar watsa labarai da duk kayan da aka haɗa har sai an warware matsalar. Ƙirƙirar ƙirar sa, ƙasa{4}} tana tabbatar da abin dogaro, rarraba wutar lantarki mai isa ga aikace-aikacen mai amfani-.

2.3 FR3 Mai

Kushin da aka ɗora - na'urar wuta yana cike da FR3® dielectric fluid, premium, wuta{2}}man ester na halitta da aka samu daga man kayan lambu. An rarraba shi azaman ruwa mai "Ƙarancin Flammable" (a kowane ASTM D6871) tare da babban ma'aunin wuta wanda ya wuce digiri 360, yana haɓaka aminci sosai a cikin jama'a ko wurare masu mahimmanci. Bayan mafi kyawun lafiyar gobara, FR3® yana ba da fa'idodin muhalli na musamman saboda yana da saurin lalacewa, ba mai guba ba, kuma yana da ƙarancin sawun carbon. Daga hangen nesa na aiki, kyakkyawan jurewar danshi da babban kwanciyar hankali na zafin rana yana ƙara tsawon rayuwar rufin cellulose, ta haka yana ƙara ƙarfin juzu'i na taswira, jinkirta tsufa, da ba da gudummawa ga tsawon rayuwar sabis tare da rage buƙatun kulawa na tsawon lokaci{10}}.
2.4 Ma'auni
Kushin da aka ɗora - na'urar wutan lantarki an sanye shi da cikakkiyar ma'auni da alamomi don ci gaba da sa ido da kariya. Ma'aunin matakin ruwa yana ba da bayyananniyar alamar gani na ƙarar ruwan dielectric don duban kulawa. Kiran bugun kira - nau'in ma'aunin zafin mai (WTI) yana lura da matsanancin zafin mai{4}} don tantance nauyin zafi. Ana lura da matsa lamba na tsarin ta hanyar ma'auni na fili/matsi, yana nuna duka ƙananan yanayi da ingantattun yanayin matsa lamba na ciki. Muhimmiyar mahimmanci, wannan ma'aunin matsa lamba an sanye shi da madaidaitan lambobi na lantarki da aka rufe ta hermetically. Ana iya saita waɗannan lambobin sadarwa don kunna ƙararrawa masu nisa ko fara tsarin sarrafawa akan gano babban saiti mai girma{9}}matsi ko matsananciyar yanayi{10}, yana mai da mai sauƙi mai nuni zuwa ɓangaren aiki na tsarin kariyar na'urar wuta. Tare, waɗannan kayan aikin suna ba wa masu aiki da mahimman bayanai na lokaci{12}} da faɗakarwar aminci.

2.4 Hoton mutum 20" tare da makulli

An sanye tafsirin da rami mai girman inci 20 da makulli. Wannan buɗaɗɗen shiga, wanda aka hatimce da gasket mai ɗorewa, yana ba wa ma'aikata izini amintaccen wurin shiga don dubawa, kulawa, da gwaji. Makullin yana aiki azaman mahimmancin aminci da yanayin tsaro, yana hana samun dama ga abubuwan rayuwa ba tare da izini ba da kuma tabbatar da amincin abin da aka rufe, mai cike da mai.
2.5 HV / LV ƙasa
Kushin da aka ɗora{0}Transfoma yana da cikakkiyar tsarin ƙasa mai ƙarfi don duka manyan abubuwan haɗin wutan lantarki (HV) da ƙananan abubuwan haɗin wutar lantarki (LV). Wannan tsarin tsaro mai mahimmanci ya haɗa da garkuwar iska ta HV, garkuwar iska ta LV, da kuma na'urar wutar lantarki da kanta - duk an haɗa su zuwa bas na gama gari. Wannan motar bas ɗin tana haɗe ta amintaccen ta hanyar ƙaramar matsananciyar matsananciyar matsananciyar matsananciyar wahala, toshe hanyar haɗi zuwa grid na waje. Ta hanyar kafa wannan madaidaicin wuri guda ɗaya, abin dogaro na ƙasa, tsarin yana tabbatar da amintaccen tarwatsewar igiyoyin wuta, ɗigowar aiki, da madaidaicin wutar lantarki. Wannan ƙira yana daidaita ƙarfin lantarki yadda ya kamata, yana ba da kariya ga ma'aikata, kiyaye kayan aiki, da haɓaka aikin dacewa da lantarki gaba ɗaya (EMC) na shigarwa.


03 Gwaji
Pad - Gwajin tankin da aka ɗora ya ƙunshi mahimman kimantawa don tabbatar da daidaiton tsari, aikin rufewa, da dacewa tare da mai mai, daidaitawa tare da ma'auni kamar ANSI C57.12.28, ANSI C57.12.00, da GB 50148{12}}2010. Waɗannan gwaje-gwajen sun haɗa da gwaje-gwajen matsa lamba inda tankin dole ne ya yi tsayayya da mafi ƙarancin psig 15 ba tare da ɗigon mai ba ko fitar da bangaren, kuma ya jure 7 psi ba tare da murdiya ta dindindin ba; gwajin nakasar injin da ya haɗa da yin amfani da vacuum -67 kPa, aunawa nakasawa a maɓalli 10 (misali, bangon tanki, murfi, ƙarfafawa) kafin da bayan sakin injin don bincika ƙaramin nakasar dindindin (yawanci 0.01-0.03 mm); da gwaje-gwajen zub da jini-ko dai ta hanyar danna madaidaicin tanki (bayan cire bawul ɗin taimako na matsin lamba) ko saka idanu canje-canjen matsa lamba, kamar yadda ci gaba da rashin tabbataccen matsin lamba na iya nuna gasket ko leaks. Bugu da ƙari, insulating mai a cikin tanki yana fuskantar gwaje-gwaje don ƙarfin dielectric, abun ciki mai ɗanɗano, da narkar da iskar gas (a kowane ASTM D3487) don tabbatar da cewa yana tallafawa rufin lantarki da kwanciyar hankali na tanki, tare da binciken bayan gwajin da ke tabbatar da rashin lalacewar tanki, tabbataccen hatimi, da bin iyakokin nakasawa don tabbatar da amintaccen aiki na waje.

04 Shiryawa da jigilar kaya


05 Yanar Gizo da Takaitawa
A ƙarshe, wannan kushin da aka ɗora{0}Transfoma yana wakiltar ingantaccen bayani na zamani, mai girma{1} wanda aka ƙera don buƙatun hanyoyin sadarwar ƙasa na yau.
Zanensa{0}wanda ke nuna ƙaƙƙarfan cibiya biyar-, ingantaccen iskar tagulla, wuta{2}}lafiya da ruwa na FR3®, da ingantaccen tsarin garkuwar ƙasa{4}yana tabbatar da ingantaccen aiki, ingantaccen aminci, da ingantaccen aikin lantarki. Haɗe-haɗen kayan aikin sa ido, haɗe tare da amintattun wuraren samun dama da kuskure{6}}tsarin ƙasa mai haƙuri, yana ba masu aiki da ganuwa da kariya mai mahimmanci. Wannan haɗe-haɗe na kayan haɓaka, injiniyan tunani, da ginannun{8}a cikin bincike yana ba da dorewa, ƙasƙanci{9}} kadarar kulawa wanda ke ba da fifikon kwanciyar hankali, amincin ma'aikata, da alhakin muhalli na dogon lokaci.

Hot Tags: na'ura mai canzawa, masana'anta, mai kaya, farashi, farashi
You Might Also Like
400 kVA Padmount Transformer-23 / 0.4 kV|Chile 2024
2500 kVA Kushin Haɓaka Masu Canjin Rarraba-25/0.6 kV...
500 kVA Mai Rarraba Rarraba Mataki na Uku-4.16 / 0.6...
1500 kVA Kushin Haɓaka Farashin Canji-23.9 / 0.416 K...
300 KVA Kushin Haɓaka Gidan Wuta-12.47*4.16/0.208 KV...
2000 KVA Centrepoint Energy Pad Hawan Canji-24.9/0.4...
Aika Aikace-aikacen