500 kVA Mai Rarraba Rarraba Mataki na Uku-4.16 / 0.6 kV|Kanada 2025
Yawan aiki: 500kVA
Ƙarfin wutar lantarki: 4.16D-0.6Y/0.347kV
Feature: tare da maɓallin kirk

Baya Gani, Ba Karya Bata Ƙarfi - Ƙarfin Ƙarfin Pad{0}Mounted Transformers.
01 Gabaɗaya
1.1 Bayanin Aikin
500 kVA uku pad da aka ɗora tasfomar da aka ɗora zuwa Amurka a cikin 2025. Ƙarfin wutar lantarkin shine 500 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 4.16D kV tare da ± 2 * 2.5% tapping range (NLTC), ƙarfin lantarki na biyu shine 0.6Y / 0.347kV, sun kafa ƙungiyar vector na Dyn1.
Wannan kushin 500kVA{1} da aka ɗora tafsiri yana fasalulluka na musamman waɗanda aka ƙera don ingantaccen aminci, amintacce, da juriya cikin buƙatun yanayin aiki.
Ba kamar daidaitattun raka'a ba, yana haɗa da tsarin kulle maɓalli na Kirk don aiwatar da amintattun jerin ayyuka da hana damar yin haɗari ga abubuwan da aka ƙarfafa, tabbatar da bin ƙa'idodin aminci. Bugu da ƙari, an sanye shi da masu kame gwiwar hannu don mafi girman kariyar wuce gona da iri, musamman a wuraren da ke da saurin kamuwa da walƙiya ko hargitsi. Transformer kuma ya haɗa da tanadin angawar girgizar ƙasa, yana ƙarfafa tsarinsa don jure ayyukan girgizar ƙasa, yana mai da shi dacewa da turawa a manyan yankuna masu haɗari- girgizar ƙasa{3}. Waɗannan fasalulluka na ci-gaba suna haɓaka tsaro na aiki gabaɗaya, rage ƙwanƙwasawa, da juriyar bala'i, suna ba da mahimman aikace-aikacen ababen more rayuwa kamar wuraren masana'antu, cibiyoyin sadarwa, da tsarin wutar lantarki na gaggawa a cikin yankuna masu girgizar ƙasa.
1.2 Ƙayyadaddun Fasaha
500 KVA kushin da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai
|
Isarwa zuwa
Kanada
|
|
Shekara
2025
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
CSA C227.4:21
|
|
Ƙarfin Ƙarfi
2500 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Radial
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
ONAN
|
|
Babban Voltage
4.16d kV
|
|
Na biyu Voltage
0.6Y/0.347 kV
|
|
Abubuwan Iska
Aluminum
|
|
Matsala ta kusurwa
Dyn1
|
|
Impedance
3.1%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
0.36 kW
|
|
Akan Rasa Load
9 kw
|
1.3 Zane
500 kVA kushin da aka ɗora zane da girman hoto.



02 Masana'antu
2.1 Kori
Wannan CSA{0}}kushin da aka ɗora{1}tasfomar da aka ɗora ya haɗa da babban{2}}ƙarfan raunin silicon karfe core, wanda aka ƙera don saduwa da ƙarfin ƙarfin kuzari da ƙa'idodin aiki. Ginin tushen rauni yana tabbatar da ingantacciyar daidaitawar maganadisu, yana ragewa babu{4}}asara da kashi 15{6}}25% idan aka kwatanta da lamintattun muryoyin gargajiya yayin haɓaka juriya mai jituwa{8}mahimmanci ga grid na zamani tare da haɓakar kuzari mai ƙarfi. CSA-tabbatacciyar don aminci da aminci.

2.2 Guda

Wannan Transformer na Coil winding Transformer yana amfani da ci-gaba na fasaha na Coil Winding, yana haɗa ƙananan iska ({0}}ƙaramar foil foil (aluminum foil) da babban{1}}ƙarar iska (wayar jan ƙarfe) don inganci da aminci. Ƙarƙashin gefen wutar lantarki - yana amfani da Multi{4}}Layer karkace, yana ba da ƙaramin tsari, mafi girman zafi, da gajeriyar juriyar kewayawa. Babban gefen wutar lantarki - yana da fasalin jujjuyawar waya ta tagulla, yana tabbatar da kyakkyawan aiki da ƙarfin injina. Tare da ƙirar coaxial yana haɓaka ƙarfin ƙarfi da haɓakar zafin jiki.
2.3 Tanko
An gina tankin wannan Transformer daga Ƙarfe mai laushi, yana ba da ƙarfin injina mai ƙarfi da dorewar lokaci mai tsawo{{0}. Ana welded da tankin kuma ana kula da shi da maganin lalata (misali, zanen ko galvanization) don jure matsanancin yanayin waje. Ƙirar ta da aka rufe amma tana da inganci ta haɗa da haƙarƙarin ƙarfafa don haɓaka juriya, hana nakasawa daga faɗaɗa mai ko gajeriyar rundunonin kewayawa-. Daidaitattun fasalulluka kamar tashar jiragen ruwa mai cike da mai, alamomin matakin, da na'urorin taimako na matsin lamba suna tabbatar da aminci da sauƙi. Farashin Mild Karfe{9}} inganci da aminci sun sa ya zama abin da aka fi so don matsakaita{10}}zuwa{11}}manyan na'urar rarraba wutar lantarki.

2.4 Maɓallin Kirki

KIRK Nau'in F interlock shine maɓalli mai sarrafa kayan aiki wanda ya dace da sarrafa kayan wutan lantarki. Naúrar daidaitaccen ta zo tare da bakin karfe 5/8 "diamita na kulle kulle tare da jifa ko tafiya na 3/4". Ana amfani da kullin kulle don sarrafa jujjuya ko motsin hannaye masu aiki ko jujjuyawar wutan lantarki. Yawancin masu samar da kayan aikin sauya kayan aiki suna da tanadin hawa don madaidaitan KIRK. An kera makullin a cikin tagulla ko bakin karfe.
03 Gwaji


04 wasu
4.1 Seismic tanadin anga
Shirye-shiryen anga na Seismic don pad - masu ɗora tafofi suna nufin ingantattun tsarin ɗorawa da ƙayyadaddun shigarwa da aka ƙera don tabbatar da naúrar zuwa ƙaƙƙarfan tushe yayin abubuwan girgizar ƙasa. yana da fasali irin su pre{2}}ramukan anga mai tsayi{3}}ƙararfi a cikin gindin da kuma amfani da ƙwararrun maƙallan girgizar ƙasa da kusoshi. Babban aikin su shine su hana na'ura mai canzawa, juyawa, ko zamewa, ta yadda za a tabbatar da daidaiton tsari, kiyaye haɗin wutar lantarki, da hana haɗari na biyu (kamar gobara ko zubewar mai) idan an fuskanci ƙayyadaddun dakarun gaggawa na ƙasa. Wannan muhimmin abin buƙatu ne na aminci ga tafkunan da aka girka a cikin girgizar ƙasa{6}}

4.2 Shipping

Ƙarƙashin sharuɗɗan CIF, mai siyar yana ɗaukar farashi, inshorar ruwa, da jigilar kaya zuwa tashar jirgin ruwa (yawanci Vancouver) don Pad{0}Mounted Transformers da aka aika zuwa Winnipeg, Kanada, tare da haɗarin canja wurin mai siye a tashar lodawa. Dole ne a cika masu canji a cikin danshi{2}}hujja ko firam ɗin ƙarfe tare da alamomin ɗagawa da tambarin ƙiyayya, tare da takaddun kasuwanci, B/L, da takaddun shaida na CSA. Bayan jigilar teku zuwa Vancouver, mai siye yana kula da izinin kwastam da jigilar kaya ta cikin gida ta hanyar dogo (kwanaki 5-7) ko babbar mota zuwa Winnipeg, lura da yuwuwar jinkirin hunturu. Mai siyar yana tabbatar da ƙimar kaya 110%, yayin da mai siye ke biyan haraji da farashin sufuri na cikin ƙasa.
05 Yanar Gizo da Takaitawa
A matsayin babban ɓangaren tsarin rarraba wutar lantarki, Pad{0}Mounted Transformer yana ba da ingantaccen, inganci, da mafita na wutar lantarki don masana'antu, kasuwanci, da ababen more rayuwa na jama'a. Haɗa sabbin fasaha tare da ƙaƙƙarfan ƙa'idodi masu inganci, muna tabbatar da kowane mai taswira yana ba da dogon aiki mai ɗorewa a cikin mahalli masu buƙata yayin inganta ingantaccen makamashi da rage farashin kulawa.
Ko kuna buƙatar ƙira na musamman ko ingantaccen ƙarfin kuzari, ƙungiyar ƙwararrun mu tana ba da ƙarshen tallafi{0}don{1}}. Zaba mu don dogara da kuma ikon rarraba wutar lantarki{3}} gina ingantaccen makamashi mai dorewa nan gaba.
Tuntube mu a yau don ingantaccen bayani!

Hot Tags: uku Phase rarraba transformer, manufacturer, maroki, farashin, tsada
You Might Also Like
75 kVA Kushin Dutsen Mai Canjawa-22.86 / 0.208 kV|Am...