4000 kVA 3 Mataki na Kushin Haɓakawa-24.94 / 0.6 kV|Kanada 2024

4000 kVA 3 Mataki na Kushin Haɓakawa-24.94 / 0.6 kV|Kanada 2024

Kasar: Kanada 2024
Yawan aiki: 4000kVA
Wutar lantarki: 24.94/0.6kV
Feature: tare da keɓe mahaɗin
Aika Aikace-aikacen

 

 

3 phase pad mounted transformer

Ƙarfin aiki mai ɗorewa, ƙwararrun ƙwararrun - Uku{0}Pad Pad -Maɗaukakiyar Canji, yana ƙara wayo!

 

01 Gabaɗaya

1.1 Fagen Aikin

Wannan 4000 kVA Pad mounted transformer an isar da ita zuwa Kanada a cikin 2023. Ƙarfin da aka ƙididdige na na'urar shine 4000 kVA, tare da babban ƙarfin lantarki 24.94GRDY/14.4 kV zuwa ƙarfin lantarki na biyu 0.6y/0.347 kV. Ƙungiyar haɗin kai shine YNyn0, sanyaya shine ONAN. Ana sanya jikin na'urar transfoma, babban maɓalli mai ɗaukar nauyi, fuse da sauran abubuwan haɗin gwiwa tare a cikin tankin na'urar, saboda nutsewa cikin mai, ƙarar bangaren yana raguwa sosai, tsarin yana da ɗanɗano, mai sauƙin shigarwa da sassauƙa. Cikakken tsari, cikakken tsari, mai aminci kuma abin dogaro, mai sauƙin aiki, kulawa{12} kyauta. Ana amfani da shi sosai a wuraren zama, manyan cibiyoyin masana'antu, masana'antu da masana'antar hakar ma'adinai, filayen jirgin sama, tashoshi, makarantu da sauran wurare.

SCOTECH ya tabbatar da kowane ɗayan na'urorin da muke bayarwa sun ci cikakkiyar gwajin karɓuwa kuma mun kasance rikodin kuskuren 0 sama da shekaru 10 ya zuwa yanzu, an ƙera taswirar mai nutsewa daidai da IEC, ANSI da sauran manyan ƙa'idodi na duniya.

 

1.2 Ƙayyadaddun Fasaha

4000 kVA kushin da aka ɗora ƙayyadaddun canji da takaddar bayanai

Isarwa zuwa
Kanada
Shekara
2024
Samfura
4000kVA-24.94GRDY/14.4-0.6y/0.347kV
Nau'in
Tashin wutar lantarki
Daidaitawa
CSA C227.4:21
Ƙarfin Ƙarfi
4000kVA
Yawanci
60HZ
Mataki
3
Nau'in Sanyi
ONAN
Babban Voltage
24.94GRDY/14.4kV
Na biyu Voltage
0.6y/0.347 kV
Abubuwan Iska
Aluminum
Matsala ta kusurwa
YNyn0
Impedance
4.5%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
5.2KW
Akan Rasa Load
33.2KW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

4000 kVA kushin da aka ɗora zane da girman hoto.

3 phase pad mounted transformer diagram 3 phase pad mounted transformer nameplate

 

 

02 Masana'antu

2.1 Kori

Ana yin taswirar core daga 0.23 zuwa 0.35 mm kauri mai kauri -mai launin toka mai birgima{3}}madaidaicin takardar silikon karfe. Dukan juzu'in nadi na sanyi{5}}mai launin toka-madaidaicin takardan siliki na ƙarfe mai ma'ana yana yanke a tsaye zuwa faɗin da ake buƙata tare da jagorar takardar siliki ta siliki a cikin layin sarrafa hob na atomatik, sa'an nan kuma ana yanke tsiri na wani faɗin a kwance a cikin guntun ƙarfe na transformer na musamman da girma dabam. Gabaɗaya, yana da digiri 45 a cikin shugabanci na tsawon takardar silicon karfe. An jera babban gidan wutan lantarki akan dandali da aka toshe don yin aiki, gabaɗaya guda biyu na stacking. A halin yanzu a cikin wutar lantarki, gabaɗaya ana amfani da miter slit core, tare da ci gaban fasahar kera taswira, miter slit core seams suna kasu kashi-kashi-kashi da mahaɗar taku. A cikin nau'in haɗin gwiwa, gabaɗaya haɗin gwiwa ne biyu masu ruɓani, wanda shine hanya guda biyu -hanyar tari mai madaidaicin kabu; A cikin nau'in suturar aji, gabaɗaya guda 5 ko 6 ne don zagayowar. Domin inganta yanayin babu{16}} na na'ura mai ɗaukar nauyi, ana karkatar da mahaɗin da aka likafa sama da ƙasa da hagu da dama, ta yadda za a samar da nau'in haɗin gwiwa da yawa na core core, wanda ake kira step hip joint. Adadin abubuwan haɗin gwiwar ƙwanƙwasa ƙafar ƙafa yana gabaɗaya a cikin nau'i na matakan 3, 5 da 6. Tare da haɓaka ƙarfin wutar lantarki, ana amfani da ainihin haɗin gwiwa mai mataki 6 a halin yanzu, kuma nau'ikan flake na core lamination suma suna karuwa saboda karuwar matakan matakai.

3 phase pad mounted transformer iron core

 

2.2 Guda

3 phase pad mounted transformer winding

Transformer winding yana jujjuya irin ƙarfin lantarki ɗaya (na lamba) zuwa wani (mita ɗaya) irin ƙarfin lantarki; ta wannan hanya, da winding a matsayin core part na transformer. Dangane da ƙimar wutar lantarki da amfani da na'urar, ta amfani da nau'ikan iska. Ɗaya daga cikin nau'ikan iskar da aka fi amfani da ita, karkace - Ƙaƙwalwar iska galibi suna karkace siffa kuma ana amfani da su azaman ƙaramar iskar wutar lantarki, amma wahalar wannan iskar tana ƙaruwa yayin da na yanzu da za a sarrafa ke ƙara girma. Babban igiyoyin ruwa suna buƙatar babban yanki{5}, don haka hasarar da ake samu a halin yanzu yana ƙaruwa. Saboda wannan dalili, ya zama dole a yi amfani da madugu biyu ko fiye da aka haɗa a layi daya don rage hasara na yanzu. Ayyukan yau shine a yi amfani da ci gaba da jujjuyawar juzu'i (tare da ɗan zagayawa kamar yadda zai yiwu) don babban matsin lamba, kuma ana samun jerin tubalan ƙarfe ta hanyar karkatar da madugu zuwa madaukai daban-daban da madaukai. Ana amfani da iska mai ƙarfi a cikin tasfoma masu ƙima mai ƙarfi, inda faifan ke yin su ta hanyar karkace madugu a matsayi ɗaya. Ana haɗa wannan madadin faifai a jere ta hanyar tsaka-tsakin ciki da waje. Wuraren da ke dafe-dafe suna da wani gini na musamman, inda wutar lantarki mai girma da ƙaranci suke a cikin tashar maganadisu ɗaya, kuma kowace babbar naúrar tana cikin tsakiyar ƙananan raka'a biyu. A sakamakon haka, ɗigon ruwa yana raguwa sosai.

 

2.3 Tanko

Akwatin wutar lantarki an yi shi ne da farantin karfe mai inganci, tare da ƙirar lalata{0}} da maganin fenti na musamman. Kaurin fim ɗin yana da 0.3mm, launi ya cika, juriya na lalata yana da ƙarfi, ƙarfin anti{3}} ultraviolet yana da ƙarfi, kuma launin yana da haɗin kai sosai tare da mahalli, wanda ya dace da yanayi daban-daban.

3 phase pad mounted transformer oil tank

 

2.4 Taron Karshe

3 phase pad mounted transformer final assembly

Tsarin akwatin Amurka - nau'in na'ura mai haɗawa ya kasu kashi biyu, gaba shine ma'aunin wutar lantarki, ma'aunin wutar lantarki ya haɗa da tashoshi masu tsayi da ƙananan wuta, babban ƙarfin wutar lantarki, toshe {{1} a cikin fiusi, babban matsi mai canjin mai aiki, mitar ɗanɗanon mai, mitar zafin mai, da sauransu; A baya akwai akwatin mai da mazubin zafi, iska mai isassun wuta, ƙarfen ƙarfe, babban ƙarfin wutar lantarki, filogi{3} a cikin fuse suna cikin jikin tanki. Load switches, fuses, da transformers ana nutsar dasu cikin mai.

Shigar da tasha a kan mahalli, sanya baƙin ƙarfe da aka haɗa a cikin tankin mai, gyara screws bayan an shigar da baƙin ƙarfe, sa'annan a saka fis mai ƙarfi. Bayan an kammala duk matakan da ke sama, cika tankin mai.

 

 

03 Gwaji

Gwajin insulation: gwada aikin rufin na'urar, gami da gwajin ƙarfin dielectric da gwajin juriya.

Gwajin zafin jiki mai girma: gwada aikin aiki da kwanciyar hankali na akwatin a ƙarƙashin yanayin zafi mai girma.

Gwajin lodi: Gwada aikin akwatin ƙarƙashin ƙimar da aka ƙididdigewa, gami da daidaiton ƙarfin wuta, ɗan gajeren lokaci{0}ƙarar yin nauyi, da sauransu.

Gwajin gajeriyar kewayawa: gwada aikin aiki da aikin aminci na akwatin ƙarƙashin gajeriyar kewayawa.

Gwajin asarar Dielectric: Gwada asarar matsakaicin ciki na akwatin don ƙayyade ƙarfin asararsa da abubuwan asararsa.

Gwajin halayen lantarki: gami da akwatin -mabambancin gwajin ƙimar ƙarfin lantarki, babu-gwajin asarar lodi, ɗan gajeren-gwajin impedance, da sauransu.

 

3 phase pad mounted transformer testing
3 phase pad mounted transformer fat

 

 

04 Shiryawa da jigilar kaya

3 phase pad mounted transformer packing
3 phase pad mounted transformer shipping

 

05 Yanar Gizo da Takaitawa

Na gode don sha'awar ku ga kushin mu guda uku - wanda aka ɗora{1} Tare da aikin sa na musamman, amintattun fasalulluka na aminci, da ingantaccen ƙarfin kuzari, wannan samfurin yana da amfani ko'ina a cikin masana'antu, kasuwanci, da sassa masu amfani, yana ba da ingantaccen ingantaccen bayani don tsarin wutar lantarki. Mun himmatu wajen isar da kayayyaki masu inganci da sabis na kulawa, kuma muna fatan yin aiki tare da ku don ƙirƙirar kyakkyawar makoma a masana'antar wutar lantarki. Don ƙarin bayani ko tallafin fasaha, da fatan za a iya tuntuɓar mu!

4000 kva 3 phase pad mounted transformer

 

Hot Tags: 3 Phase pad mounted transformer, manufacturer, maroki, farashin, farashi