300 kVA Mai Cika Mai Sauƙi-13.2 / 0.48 kV|Guyana 2024
Yawan aiki: 300kVA
Wutar lantarki: 13.2/0.48kV
Siffar: tare da CLF

Dogara, mai ɗorewa, da ƙarfi - ingantaccen - Uku-Pad Pad{2}Mounted Transformer yana sake fasalin ma'auni na tsarin wutar lantarki!
01 Gabaɗaya
1.1 Fagen Aikin
300 kVA pad mounted transformer an isar da ita zuwa Amurka ta Kudu a cikin 2024. Ƙarfin wutar lantarkin shine 300 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 13.2GrdY / 7.62kV tare da ± 2 * 2.5% tapping range (NLTC), ƙarfin lantarki na biyu shine 0.48 / 0.277kV, sun kafa ƙungiyar vector na YNyn0, kuma shine madaidaicin ciyarwa da matattarar gaba. Pad mounted transformer ne m kuma yana da ƙaramin sawun ƙafa, yana mai da shi dacewa musamman don amfani a cikin birane da wurare masu iyakacin sarari. Pad mounted transformer yana haɗe tafsiri, babban{13}}ƙaramar sauya wutar lantarki, ƙanana{14}}kayan rarraba wutar lantarki da kayan taimako a cikin akwati guda, yana guje wa matsalar tarwatsewar shimfidar na'urorin tashar na gargajiya. Kammala taron gabaɗaya da ƙaddamar da kayan aikin a cikin masana'anta, kuma kawai kuna buƙatar haɗa manyan igiyoyin lantarki masu ƙarfi da ƙananan ƙarfin lantarki zuwa rukunin yanar gizon don fara aiki, suna rage lokacin gini sosai. Fa'idodin ƙira na na'urar taswira ta Amurka tana nunawa a cikin ƙayyadaddun ƙirar tsari, babban tsaro, ƙarancin kulawa da haɓaka sassauƙa. Wadannan halaye sun sa ya dace da aikace-aikace a cikin rarraba wutar lantarki na birane, hadaddun kasuwanci, wutar lantarki, photovoltaic da sauran al'amuran da ke buƙatar sararin samaniya, aminci da inganci.
An ƙera injin mu 300 KVA pad ɗin da aka ɗora shi tare da fasaha na ci gaba kuma yana ɗaukar kayan inganci da abubuwan haɗin gwiwa waɗanda ke haifar da ingantaccen inganci da tsawon lokacin aiki.
1.2 Ƙayyadaddun Fasaha
300 KVA nau'in ƙayyadaddun bayanai da takaddun bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2024
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
IEEE C57.12.34
|
|
Ƙarfin Ƙarfi
300 KVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Nau'in Sanyi
ONAN
|
|
Babban Voltage
13.2GrdY/7.62 KV
|
|
Na biyu Voltage
0.48/0.277 KV
|
|
Abubuwan Iska
Aluminum
|
|
Matsala ta kusurwa
YNyn0
|
|
Impedance
5±7.5%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
0.45KW
|
|
Akan Rasa Load
3.16KW
|
|
Na'urorin haɗi
Daidaitaccen Kanfigareshan
|
1.3 Zane
300 KVA kushin da aka ɗora zane da girman hoto.
![]() |
![]() |
02 Masana'antu
2.1 HV
Matattun na'urori na gaba don masu taswira suna haɓaka aminci (yana rage girman kai{0}}arancin wutar lantarki/haɗarin arc) kuma yana ba da damar ƙananan girman ma'aikatun ta hanyar raguwar share fage. Mafi qarancin gama gari a cikin masu taswirar padmount a yau, ana amfani da bushing na gaba kai tsaye lokaci-lokaci don haɗin farko na HV. Matattun musaya na gaba (mafi yawa 200A loadbreak; 600/900A waɗanda ba-zaɓin zazzagewa) ba a cika yin amfani da su ba don ƙarewar LV ta biyu saboda goyan bayan kebul ɗaya kawai a kowane mai haɗin gwiwar gwiwar hannu (marasa jituwa da multi- na USB a kowane saitin lokaci).

2.2 LV goyon bayan bushing

Lokacin ƙananan madaidaicin madaidaicin wutar lantarki ya haɗa da ƙarin ramuka masu hawa, gabaɗaya suna girma tsawon tsayi. Idan spades ɗinku suna da ramuka da yawa (saboda haka ana haɗa su da igiyoyi da yawa), ƙara ƙaramar tallafin bushewar wutar lantarki yana zama ma'auni mai mahimmanci. Goyan bayan Bushing kuma kyakkyawan la'akari ne idan kuna aiki tare da kari na spade.
Za a iya daure kurmi mara tallafi ta nauyin manyan igiyoyi masu nauyi da yawa da ke haɗe da shi. Wannan nauyin da ya wuce kima na iya damfara sashin gasket na bushing (wanda ke zaune da bangon tanki na wuta). A tsawon lokaci, wannan matsi na iya haifar da zubar da mai na transformer wanda ke farawa daga saman yankin gasket.
2.3 Tanko
Masu canjin famfo suna aiki ta hanyar zaɓar saitin da ya yi daidai da ainihin ƙarfin lantarki mai shigowa{{0}wannan yana riƙe ƙarfin fitarwar lodin da ya dace da ƙimar farantin suna na taransfoma.
Idan wutar lantarki mai shigowa yayi ƙasa da ƙasa: Juya mai canza fam ɗin majalisar HV zuwa ƙaramin saiti. Wannan yana cire haɗin ƙananan ɓangarori na iskar farko (rage ƙidayarsa, yayin da sakandare ke zama ba canzawa). Matsakaicin juyi da aka daidaita yana haɓaka ƙarfin wutan gefe{2} na biyu, yana gyara ƙarancin shigarwar.

2.4 Taron Karshe

Wannan toshe ne -a, na yanzu{1}}iyakance fiusi da aka sanya akan babban na'urar wutar lantarki{2}}bangaren wutar lantarki. Yana hidima a matsayinmadadin kariyaa kan kurakuran ciki ko na sakandare{0}. Mabuɗin fasalinsa sun haɗa da asalon bayonet{0}zane don amintaccen maye gurbin hannu,saurin katsewar halin yanzudon iyakance kuzarin kuskure, da kuma anuna alama(kamar fil fil) don nuna aiki a fili. An haɗa fis ɗin tare da ƙimar taswira don tabbatar da zaɓen zaɓe, samar da mafita mai sauƙi kuma amintaccen kariya ta waje.
2.5 Taron Karshe
Maɓallin ɗaukar nauyi shine - sandar igiya, SF6{2}} na'urar sauya sheka wacce aka ɗora a gefen babban ƙarfin lantarki, wanda aka ƙera don yin lami lafiya da karya magudanar ruwa. Mabuɗin fasalinsa sun haɗa dacire haɗin bayyanedon ware,matattu{0}} gini na gabadon amincin ma'aikaci, anhannun rotary na wajedon aiki da hannu, da kuma haɗawabaka{0}} iyawar kashewa(yawanci amfani da SF6 gas ko injin). Wannan jujjuya tana ba da damar amintaccen sashe, ƙarfin wutar lantarki/de{2}}ƙarfafawa, da keɓewar kuskure ba tare da buƙatar cire gwiwar gwiwar igiya ba, haɓaka sassaucin tsarin da amincin kiyayewa.

03 Gwaji


04 Shiryawa da jigilar kaya


05 Yanar Gizo da Takaitawa
Na'urar Canji mai Saurin Mataki na Uku, tare da ƙwararren aikin sa, amintaccen ƙira, da tsayayyen aiki, shine mafi kyawun zaɓi don rarraba wutar lantarki. Ko a cikin aikace-aikacen kasuwanci, masana'antu, ko na jama'a, dogaro da kai yana biyan buƙatu iri-iri, samar da masu amfani da inganci, makamashi{1}}ajiya, da farashi{2}masu amfani da wutar lantarki. Zaɓi Canjin Fasinja na Mataki na Uku don tabbatar da aminci da ingantaccen ƙarfi don ayyukanku kuma don ba da gudummawa mai ƙarfi ga ci gaba mai dorewa a nan gaba.

Hot Tags: mai cike da wutar lantarki, masana'anta, mai kaya, farashi, farashi
You Might Also Like
2500 kVA Residential Electrical Transformers-34.5/0....
75 kVA Kushin Dutsen Mai Canjawa-22.86 / 0.208 kV|Am...
150 kVA Kushin Haɗa Mai Canjawa-34.5 / 0.208 kV|Amur...
300 kVA Pad -wanda aka ɗora Transformer-34.5/0.208 k...
250 kVA Kushin Haɗa Mai Canjawa-23 / 0.4 kV|Chile 2024
500 kVA Utility Pad Hawan Canji-24 / 0.48 kV|Amurka ...
Aika Aikace-aikacen