2500 kVA Residential Electrical Transformers-34.5/0.6 kV|Usa 2025

2500 kVA Residential Electrical Transformers-34.5/0.6 kV|Usa 2025

Ƙasar Bayarwa: Amurka 2025
Yawan aiki: 2500kVA
Wutar lantarki: 34.5/0.6kV
Fasalin: LV Gefen Flanged -Hannun Bushings
Aika Aikace-aikacen

 

 

2500 kVA residential electrical transformers

Ƙaddamar da grid masu wayo na ƙasa tare da na'urorin lantarki na zama na 2500 kVA waɗanda aka gina don inganci da aminci.

 

01 Gabaɗaya

1.1 Fagen Aikin

A cikin 2025, mun isar da na'urorin lantarki na zama na 2500kVA ga abokin ciniki a Amurka don tallafawa tsarin rarraba wutar lantarki na zamani. An gina shi don saduwa da IEEE Std C57.12.34 -2022 da DOE 2016 ka'idojin ingancin makamashi, wannan kushin da aka ɗora tafsiri yana ba da ingantaccen aminci, tanadin makamashi, da fa'idodin muhalli na dogon lokaci.

Naúrar tana fasalta ciyarwar madauki, ƙirar gaba ta mutu, tabbatar da aiki mai aminci da sauƙin kulawa a ƙaƙƙarfan mahallin birane. Yana amfani da man ester na halitta na FR3, wuta -lafiya, ruwa mai ɗorewa mai yuwuwa don gina gidaje, kasuwanci, da cibiyoyi inda aminci da dorewa ke da mahimmanci.

Tare da rufaffiyar shinge da gefe{0}maɗaukaka madaidaicin madaidaicin wutar lantarki, wannan gidan wutan lantarki an inganta shi don haɗin kebul na ƙasa a cikin haɓaka grid mai kaifin baki, gundumomin kasuwanci, wuraren shakatawa na masana'antu, da wuraren amfani. Karamin sawun sa da aikin shiru ya sa ya dace don wurare masu tsananin sarari da hani.

Ta hanyar haɗa babban inganci (99.53%), ƙaƙƙarfan rufi, da daidaita wutar lantarki mai sassauƙa, wannan rukunin yana samar da ingantaccen, ƙaramar ikon kulawa wanda aka dace da aikace-aikacen grid na Arewacin Amurka.

 

 

1.2 Ƙayyadaddun Fasaha

2500kVA mazaunin wutar lantarki ƙayyadaddun bayanai da takaddun bayanai

Isarwa zuwa
Amurka
Shekara
2025
Nau'in
Uku fanni kushin Dutsen transformer
Daidaitawa
IEEE Std C57.12.34-2022
Ƙarfin Ƙarfi
2500 kVA
Yawanci
60HZ
Ciyarwa
Madauki
Gaba
Matattu
Mataki
Uku
Nau'in Sanyi
KNAN
Liquid insulant
Farashin FR3
Babban Voltage
34.5 kV
Na biyu Voltage
0.63 kV
Ƙungiyar Vector
YNyn0
Abubuwan Iska
Aluminum
Impedance
5.75%
Ƙimar inganci da hasara
DOE 2016
inganci
99.53 %
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
2.4 kW
Akan Rasa Load
15.79 kW

 

1.3 Zane

2500kVA mazaunin wutar lantarki girma da cikakkun bayanai masu nauyi

2500 kVA residential electrical transformers drawing 2500 kVA residential electrical transformers nameplate

 

 

02 Masana'antu

2.1 Kori

Jigon ya ƙunshi manyan ƙafafu uku da ƙafafu masu taimako biyu. Magnetic jujjuyawar yana gudana ta manyan ƙafafu biyu da na mataimaka, yana ba da ƙarin hanyoyin da ke haɓaka ƙulli. Wannan ƙira yana tabbatar da ingantaccen aiki a ƙarƙashin kaya mara daidaituwa kuma babu{2}} yanayin lodi, yana rage girgiza da hayaniya. Ƙafafun biyar- yana gudana cikin nutsuwa da dogaro, yana mai da shi manufa don rarraba birane da kasuwanci inda ake buƙatar ƙaramar amo da babban abin dogaro.

core consists of three main legs and two auxiliary legs

 

2.2 Guda

low-voltage foil winding and high-voltage wire winding

Wutar lantarki da aka ɗora taswira tana amfani da ƙaramin{0}}ƙarar iska da iska mai ƙarfi{1}}wayar wutar lantarki tare da madubin aluminium mai laushi don ingantacciyar aiki da rage asara. An yi coil ɗin da aluminum don tafiyar da aikinsa da nauyi mai sauƙi. A cikin hoton, ma'aikaci yana matsar da screws na faranti don amintar da coil, yana shirya mataki na gaba. Wannan yana tabbatar da matsananciyar matsawa, yana haɓaka kwanciyar hankali na inji, yana rage rawar jiki, da haɓaka aminci da inganci yayin aiki.

 

2.3 Tanko

Na'urar taswirar lantarki ta zamani guda uku - tana da tankin ƙarfe mai laushi da aka rufe tare da murfi, foda{1}}mai rufi a cikin RAL 9003 fari don juriyar lalata. An sanye shi da ɗorawa masu ɗagawa da faifan jacking don sauƙin sarrafawa. Yana ƙetare gwajin zub da jini na 50kPa na sa'o'i 12 ba tare da yabo ko nakasawa ba, yana tabbatar da ingantaccen hatimi da amincin tsari.

sealed mild steel tank of residential transformer

 

2.4 LV Gefen Flanged -Maɗaukakin Bushings

lv-flanged-side-mounted-bushings

Fuskar kushin da aka ɗora tasfoma guda uku - yana da ƙanƙantar ƙirar wuta mai ƙarancin wuta, yana ba da damar haɗi mai sauƙi da aminci zuwa igiyoyi na ƙasa. Gefen -madaidaitan tashoshi na LV ana kiyaye su ta akwatin kebul ɗin da aka hatimi, yana tabbatar da aminci, sarari{3} ingantacciyar shigarwa a cikin cibiyoyin rarraba birane da tsarin wutar lantarki na kasuwanci.

 

2.5 Taron Karshe

Core & Coil Assembly
Aluminum windings (YNyn0) an manne a kan ainihin don sanyaya KNAN. Insulation da tazara sun haɗu da 34.5 kV/0.63 kV da 5.75% ƙayyadaddun ƙayyadaddun impedance.

Tanki Shiri
Tanki mai rufi da fenti mai jurewa FR3. Maɓalli masu mahimmanci: bawul ɗin taimako na matsa lamba, ma'aunin mai/vacuum, da cika filogi tare da tashar jiragen ruwa.

Matsayin Majalisa
Core{0}} ana gyarawa a cikin tanki. NLTC (± 2 × 2.5%) rike da aka mika zuwa murfin.

Haɗin gwiwar Side HV
Load break switch, bayonet and CLF fus shigar a matattu{0}}bangaren gaba don ciyarwar madauki.

Cika Wuta
Man FR3 cike a ƙarƙashin ƙasa ko daidai da injin 0.5 mbar. Magudanar ruwa tare da ƙara tashar samfur.

Saka idanu Shigarwa
Babban ma'aunin zafi da sanyio mai da firikwensin firikwensin 4-20mA da aka haɗa zuwa akwatin tasha.

Ƙarshe Waya & Gwaji
Waya don canza famfo, ma'auni, da na'urori masu auna firikwensin (lakabi A/B/C). Juriya na insulation kuma babu - asarar nauyi (2.4 kW manufa) da aka gwada.

residential electrical transformers final assembly

 

 

03 Gwaji

residential electrical transformers routine test
residential electrical transformers factory testing

Gwajin Na yau da kullun da Matsayin Gwaji

1. Ma'aunin Juriya: Dangane da IEEE C57.12.90-2021 Sashe na 5

2. Gwajin Rabo: Dangane da IEEE C57.12.90-2021 Sashe na 7

3. Mataki -Gwajin dangantaka: Dangane da IEEE C57.12.90-2021 Sashe na 6

4. Babu Asara Load kuma Babu Load A halin yanzu: Dangane da IEEE C57.12.90-2021 Sashe na 8

5. Haɓaka Load, Ƙarfin Wutar Lantarki da inganci: Dangane da IEEE C57.12.90-2021 Sashe na 9

6. Gwajin Ƙarfin Wutar Lantarki: Dangane da IEEE C57.12.90-2021 Sashe na 10.6

7. Ƙwararren Ƙwararren Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararru: Dangane da IEEE C57.12.90-2021 Magana 10.5.1

Ma'aunin Resistance Insulation

8. Gwajin Leak tare da Matsi don Masu Canjin Ruwa na Ruwa: Za a gudanar da gwajin zubar da ruwa a 50KPa don 12h ba tare da yaduwa ba. Babu nakasar dindindin.

9. Ma'aunin Juriya na Insulation

 

Sakamakon Gwaji

A'a.

Gwajin Abun

Naúrar

Dabi'un Karɓa

Ƙimar Ma'auni

Kammalawa

1

Ma'aunin Juriya

%

Matsakaicin juriya rashin daidaituwa

4.58

Wuce

2

Gwajin Rabo

%

Bambancin rabon ƙarfin lantarki akan babban tapping: ƙasa da ko daidai da 0.5%

Alamar haɗi: YNyn0

0.01% ~ 0.03%

Wuce

3

zango{0}}gwajin dangantaka

/

YNyn0

YNyn0

Wuce

4

A'a -asara da tashin hankali na halin yanzu

/

I0 :: bayar da ma'auni darajar

0.18%

Wuce

P0: bayar da ƙima (t:20 digiri)

2.281 kW

juriyar rashin hasara shine +10%

/

5

Load hasarar impedance ƙarfin lantarki da inganci

/

t:85 ku

haƙuri ga impedance shine ± 7.5%

juriyar jimlar asarar kaya shine +6%

/

Wuce

Z%: ƙimar da aka auna

6.00%

Pk: ƙimar ƙima

15.091 kW

Pt: ƙima mai ƙima

17.372 kW

Ingancin ba kasa da 99.53%

99.55%

6

Gwajin Karfin Wutar Lantarki

kV

LV: 10kV 60s

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

7

Ƙunƙarar Wutar Lantarki Juriya Tes

kV

Wutar lantarki mai aiki (KV):2Ur

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

Duration(s):48

Mitar (HZ): 150

8

Gwajin Leaka

kPa

Aiwatar da matsa lamba: 50kPA

Babu yabo kuma babu

Lalacewa

Wuce

Tsawon lokaci: 12h

9

Ma'aunin Resistance Insulation

GΩ

HV{0}LV zuwa Ground:

1.40

/

LV -HV zuwa Ground:

1.53

 

 

04 Shiryawa da jigilar kaya

4.1 Shiryawa

tin foil bag packing of transformer
2500 KVA Residential Electrical Transformers packing

 

4.2 Shipping

2500 KVA Residential Electrical Transformers shipping

 

 

 

05 Yanar Gizo da Takaitawa

SCOTECH ta sami karramawa da ta isar da pad{0}masu tasfofi ga abokin cinikinmu na Amurka, suna ba da gudummawa ga buƙatun rarraba wutar lantarki tare da ingantattun mafita.

Tare da mai da hankali kan saduwa da ƙa'idodin IEEE da DOE, ƙungiyarmu ta tsara a hankali, ƙera, da gwada waɗannan na'urorin wutar lantarki na mazaunin don tabbatar da aiki da dorewa. Wannan aikin ƙoƙarin haɗin gwiwa ne, kuma muna godiya da amincewa da abokin cinikinmu ya ba mu.

A matsayinmu na kamfani mai himma ga ci gaba da haɓakawa, muna ƙoƙarin inganta ƙwarewar injiniyarmu da damar sabis don tallafawa abubuwan samar da makamashi na duniya. Muna sa ran samun damammaki nan gaba don samar da ɗorewa da ingantaccen mafita na transfoma ga abokan haɗin gwiwa a duk duniya.

Na gode da zabar SCOTECH{0}muna ci gaba da sadaukar da kai don ƙware a fasahar wutar lantarki da gamsuwar abokin ciniki.