3000 kVA Kushin Haɓaka Mai Canjawa-25 / 0.6 kV|Kanada 2025
Yawan aiki: 3000 kVA
Wutar lantarki: 25GrdY/14.434-0.6Y/0.347kV
Feature: tare da saman man ma'aunin zafi da sanyio

Ƙarfin Ƙarfin Ƙarfi Inda Kuna Buƙatar Shi - Kushin -Masu Sauƙaƙe don Giriyoyi na Zamani.
01 Gabaɗaya
1.1 Bayanin Aikin
3000 kVA three phase pad mounted transformer an isar da ita zuwa Kanada a shekarar 2025. Ƙarfin wutar lantarkin shine 3000 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 25GrdY / 14.434 kV tare da kewayon tapping ± 2 * 2.5% (NLTC), ƙarfin lantarki na biyu shine 0.6Y / 0.347 kV, sun kafa ƙungiyar vector na YNyn0.
CSA- ƙwararrun kushin mu{1} ɗora kayan aikin wuta an ƙera su don aminci, abin dogaro, da ingantaccen rarraba wutar lantarki a aikace-aikacen birane, kasuwanci, da masana'antu. An ƙirƙira su don saduwa da ƙa'idodin CSA C227.4:21, waɗannan ƙaƙƙarfan raka'a suna tabbatar da cikakken cika buƙatun amincin lantarki na Kanada, suna ba da kyakkyawan aiki a cikin yanayin yanayi mai tsauri da manyan mahalli-.
Haɗe da ƙaƙƙarfan ƙaƙƙarfan ƙaƙƙarfan ƙaƙƙarfan tarkace{0}, tsarin sanyaya na ci gaba, da kuma lalata{1}}kayan da ke jurewa, tafkunan namu suna ba da dorewar dogon lokaci tare da ƙaramar kulawa. Ko don jujjuyawar ƙasa -zuwa{5}}waye na sama, haɗin makamashi mai sabuntawa, ko haɓaka grid mai amfani, CSA{6}}kushin da aka yarda da shi{7}masu tafsirai suna ba da amintattun hanyoyin rarraba wutar lantarki da goyan bayan gwaji mai ƙarfi da tabbacin inganci.
1.2 Maɓalli na Ƙira
![]() |
Babban Plug na ringi{0}A cikin Tsarin Babban Haɗin Wutar Lantarki & Ƙarfafa Matattu na gaba{0}} Ƙarshen Zane BIL & Shirye-shiryen Bushing |
1.3 Ƙimar Fasaha
3000 kVA kushin da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai
|
Isarwa zuwa
Kanada
|
|
Shekara
2025
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
CSA C227.4:21
|
|
Ƙarfin Ƙarfi
3000 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
ONAN
|
|
Babban Voltage
25GrdY/14.434 kV
|
|
Na biyu Voltage
0.6Y/0.347 kV
|
|
Abubuwan Iska
Aluminum
|
|
Matsala ta kusurwa
YNyn0
|
|
Impedance
5.75%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
3.46 kW
|
|
Akan Rasa Load
27 kW
|
1.4 Zane
3000 kVA kushin da aka ɗora zane da girman hoto.
![]() |
![]() |
02 Masana'antu
![]() |
Ƙarfin ƙarfe:Babban ƙarfe na pad -wanda aka ɗora tasfoma yawanci yana da nau'in cibiya guda uku{1}}fase biyar{2}}, an gina shi daga manyan laminations na silicon karfe. Wannan ƙira ta ƙunshi manyan gaɓoɓi guda uku (don jujjuya coils ɗin lokaci guda uku-) da gaɓoɓi na taimako guda biyu, samar da rufaffiyar da'irar maganadisu don rage girman asara da zubewar ruwa. Lambun yadudduka suna rage hasara na yanzu, yayin da tsarin kafa guda biyar{8} yana haɓaka ma'aunin maganadisu, yana mai da shi manufa don ɗaukar nauyi{9} dabam-dabam aikace-aikace tare da ingantaccen aiki da ƙaramar amo. |
![]() |
Iska: Ƙaƙƙarfan kushin ({0}}wanda aka ɗora tasfoma yana da haɗaɗɗiyar ƙira ta ƙaramar iska mai ƙarfi da ƙaramar iska mai girma{2}}wayar wutar lantarki. Ƙunƙarar farko a kan babban gefen ƙarfin lantarki yana rauni tare da keɓaɓɓen waya ta jan ƙarfe don haɓaka ƙarfin wutar lantarki da ingancin sanyaya. The low-voltage side employs aluminum or copper foil windings with interlayer insulation, offering compact construction, reduced losses, and high mechanical stability. Wannan nau'in juzu'i na iska yana inganta ingantaccen injin na'ura da amincin buƙatun aikace-aikacen waje. |
![]() |
Tanki: Tankin pad - na'ura mai ɗorewa yawanci yana ɗaukar tankunan mai, wanda aka yi shi daga lalata{1}}ƙarfe tare da ɗakin mai na ciki da harsashi na waje don hana ɗigogi da gurɓata muhalli. Ƙaƙƙarfan tanki yana fasalta ƙarfafa haƙarƙari don juriya na matsa lamba da haɗaɗɗen fins mai sanyaya don ingantaccen watsawar zafi. Wannan ƙira ta bi ƙa'idodin muhalli yayin da ke tabbatar da dogon{4}} amintaccen hatimi da aminci a cikin aiki na waje. |
![]() |
Ƙarƙashin Ƙarƙashin Ƙasa: Yana ba da ƙaramin -hanyar rashin ƙarfi{1}} don haka duk wani yunƙurin da ba zato ba tsammani, kuskuren halin yanzu, yana shiga cikin ƙasa kai tsaye, yana kiyaye mutane da kayan aiki. Hakanan yana taimakawa tare da tsangwama na lantarki, wuce gona da iri waɗanda ke tashi lokacin da ƙasa ba cikakke ba. Copper, mai ƙarfi da juriya na lalata, mai jagora mai kyau sosai; yana dadewa, abin dogaro akan lokaci, mai sauƙin amincewa da aiki. CSA Ground Bracket: Madaidaicin wurin hawa don haɗa wayoyi na ƙasa ko madauri; yana tabbatar da ƙasa ya cika ka'idodin aminci na CSA, buƙatun takaddun shaida. Ƙirar ƙwanƙwasa - mai ƙarfi, yana jure wa damuwa na inji, girgiza, iska, lalata; yana ba da mafita mai dorewa, abin dogara, mai sauƙin shigarwa da dubawa. |
03 Gwaji
|
A'a. |
Gwajin Abun |
|
| 1 |
Ma'aunin Juriya |
![]() |
| 2 |
Gwajin Rabo |
![]() |
| 3 |
Mataki{0}}gwajin dangantaka |
![]() |
| 4 | A'a -asara da tashin hankali na halin yanzu | ![]() |
| 5 | Load hasarar impedance ƙarfin lantarki da inganci | ![]() |
| 6 | Gwajin Karfin Wutar Lantarki | ![]() |
| 7 | Jarrabawar Juriya da Wutar Lantarki | ![]() |
| 8 | Gwajin Leaka | ![]() |
| 9 | Ma'aunin Resistance Insulation |
|
| 10 | Gwajin Mai |


04 Shiryawa da jigilar kaya
4.1 Shiryawa
1. Sanya taransfoma na lokaci 3 akan tire, a rufe shi da jakar foil na gwangwani, da farko rufe jakar tare da buɗewa hagu, share ta cikin buɗewa, sannan rufe buɗewar. Saka desiccant a ciki don hana tsatsa.
2. Ƙara masu kare kusurwa (kumfa / filastik / kwali) a kusa da mai canzawa kuma kunsa shi da fim mai kariya.
3. Kunna shi a cikin akwati na katako da fesa cokali mai yatsa da tsakiyar alamun nauyi akan akwatin.

4.2 Shipping

Kushin da aka ɗora{0}Transfoma yana cushe a cikin wani akwati na katako kuma an loda shi a kan babbar mota ta hanyar amfani da cokali mai yatsu, sannan a kai shi zuwa tashar ruwa. Ana jigilar shi ƙarƙashin sharuɗɗan CIF (Cost, Insurance, and Freight) ta hanyar jigilar kaya zuwa tashar jiragen ruwa na Montreal, Kanada. Gabaɗayan tsarin yana tabbatar da danshi{3}}hujja, juriya, da amintaccen ɗaure bisa yarda da ƙa'idodin jigilar kaya na duniya.
05 Amfanin Ayyuka
Babban Haɓaka & Ƙarfin Asara
Ingancin ya kai kashi 99.37%, yayin da babu -asara da lodi da ke raguwa{2}}yana rage kuzari, yana rage tsadar gudu.
Aluminum Windings mai ɗorewa
Aluminum windings, daidaitacce kuma dorewa -; haske, mai ƙarfi, ƙarancin kulawa. An ƙera shi don aiki mai nauyi{2}, amma ana iya tsinkaya a cikin amfanin yau da kullun.
Yawaita Ƙarfin & Amincewa
Yana ɗaukar kaya da yawa da kyau. Ko da a ƙarƙashin babban kaya na kwatsam, yana tsayawa tsayin daka. Babban dogaro, yana rage raguwar lokaci.
Daidaitaccen Aiki a cikin Tsarukan Mataki na Uku{0}
Yana kiyaye daidaitattun matakai guda uku. Aiki mai laushi, ƙarancin lahani. Gabaɗaya, kuzari - inganci, mai aminci, da sauƙin aiki{3}}masu aiki na iya dogara da shi kowace rana.