100 MVA High Voltage Power Masu Canzawa-132/22 kV|Malaysia 2023
Yawan aiki: 100MVA
Wutar lantarki: 132/22kV
Feature: tare da OLTC

Masu canza wuta - zuciyar kwanciyar hankali da kashin bayan grid mai ƙarfi!
01 Gabaɗaya
1.1 Fagen Aikin
Biyu 100 MVA 132kVwutar lantarkiAn kai su Malaysia a watan Disamba 2023. Ya kamata a yi amfani da na'urorin wutar lantarki mai karfin MVA 100 a cibiyar bayanan TikTok a Malaysia. Ƙarfin da aka ƙididdige wannan wutar lantarki shine 100 MVA tare da sanyaya ONAN/ONAF, babban ƙarfin lantarki shine 132 kV tare da +7×1.5% zuwa -17×1.5% tapping range(OLTC), matsakaicin ƙarfin lantarki shine 33 kV tare da ± 2 × 2.5% tapping range (NLTC), kuma ƙananan ƙarfin lantarki shine 22 kV. Manyan taranfoma na 132kV guda biyu, ta yin amfani da samfurin kamfani na SFSZ{18}}100000/132 guda uku{19}} na'ura mai sanyaya iska mai sanyaya akan kaya mai sarrafa wutar lantarki, sun kafa ƙungiyar vector na YNd1d1.
Babban wutar lantarki mai girman MVA 100 na'urar lantarki ce mai ƙarfi kuma abin dogaro wanda aka ƙera don isar da wutar lantarki da kyau tsakanin matakan ƙarfin lantarki daban-daban. Ana kera tasfoman wutar lantarki ta hanyar amfani da manyan kayayyaki masu inganci da yanayin{4}}- fasaha don tabbatar da ingantaccen aiki da dorewar dogon lokaci
Mun tabbatar da cewa kowane ɗayan rukunin da aka kawo mu ya yi cikakken gwajin karɓa. Muna ba da sabis na fakiti ɗaya{1} daga tuntuba, ambato, masana'anta, shigarwa, ƙaddamarwa, horarwa zuwa sabis na siyarwa, samfuranmu yanzu suna aiki a fiye da larduna 50 a duniya. Muna nufin zama mafi girman kuabin dogara marokida kuma mafi kyawun abokin tarayya a cikin kasuwanci!
1.2 Ƙayyadaddun Fasaha
100 MVA babban ƙarfin wutar lantarki na wutar lantarki da takaddun bayanai
|
Isarwa zuwa
Malaysia
|
|
Shekara
2023
|
|
Samfura
SFSZ-100000/132
|
|
Nau'in
Mai Narke Mai Canza Wutar Lantarki
|
|
Daidaitawa
Saukewa: IEC60076
|
|
Ƙarfin Ƙarfi
100MVA
|
|
Yawanci
50HZ
|
|
Mataki
Uku
|
|
Nau'in Sanyi
ONAN 70MVA / ONAF 100MVA
|
|
High Voltage
132kV
|
|
Matsakaicin Wutar Lantarki
33kV
|
|
Low Voltage
22kV
|
|
Abubuwan Iska
Copper
|
|
Polarity
Ƙara
|
|
Impedance
35.43%
|
|
Matsa Canji
OLTC/NLTC
|
|
Taɓa Range
132+7×1.5% -17×1.5%
|
|
Babu Asara Load
30.14 kW
|
|
Akan Rasa Load
470.675 kW
|
|
Na'urorin haɗi
Daidaitaccen Kanfigareshan
|
|
Jawabi
N/A
|
1.3 Zane
100 MVA babban ƙarfin wutar lantarki na wutar lantarki zane da girman zane.
![]() |
![]() |
02 Masana'antu
2.1 Kori
Ana yin ginshiƙin baƙin ƙarfe daga babban{0}sa, hatsi{1}} silikon ƙarfe laminations, waɗanda aka jeri kuma an ɗaure su tare don samar da ingantaccen cibiya. Yin amfani da irin waɗannan kayan yana da mahimmanci don rage asarar makamashi saboda raƙuman ruwa da ƙuƙwalwa. Babban aikin jigon baƙin ƙarfe shine samar da ƙaramar hanya{4}}ƙaƙƙarfar ƙaƙƙarfan motsin maganadisu da aka samar ta hanyar iskar farko ta transformer. Wannan motsi na maganadisu yana haifar da ƙarfin lantarki a cikin iska na biyu, don haka yana sauƙaƙe sauƙin canja wurin makamashin lantarki daga wannan da'ira zuwa wata.

2.2 Guda

Gilashin wutar lantarki mai ƙarfin wutar lantarki guda biyu suna ci gaba da ci gaba, ƙarfin injina mai ƙarfi, kyakkyawan aikin watsawar zafi, tare da wayoyi masu lebur 1 zuwa 6 akan strut da rauni a cikin sashin layin cake. Kek tare da tashar mai ko mai da zoben crisscross sun rabu, duka ƙarshen tashar mai da zoben rufi.
2.3 Tanko
An yi tankin mai canzawa da faranti na ƙarfe da aka yi wa walda kuma an ƙarfafa shi don samar da ƙarfin injina da kariya ga abubuwan ciki na na'urar don jure wa sufuri, sarrafawa da matsi a ƙarƙashin yanayi mara kyau ba tare da murdiya ba. Lokacin da taswirar ke aiki akai-akai, ana iya bincika tushen tankin mai ba tare da amfani da kowane kayan aiki na musamman ba. Don tabbatar da amincin ma'aikata, yayin lokacin lodawa na yau da kullun, yanayin zafin jiki shine digiri 40 C, matsakaicin zafin jiki na tanki (inda mutane zasu iya isa) shine 70 ° C.

2.4 Taron Karshe

Haɗin ƙarshe na manyan injinan wutan lantarki ya haɗa da haɗakar abubuwa kamar ƙarfe core, winding da tsarin insulation don samar da cikakkiyar na'urar taswira. Tsarin ya ƙunshi matakai masu zuwa:
Babban Taro: Haɗa ainihin abubuwan haɗin gwiwa tare, da tara manyan zanen ƙarfe na siliki{0} don samar da ingantattun da'irori na maganadisu da rage asarar kuzari.
Ƙungiyar Winding: shigar da coils na iska a kan ainihin, ciki har da na farko da na biyu, yana buƙatar tsari mai mahimmanci da kuma rufi don tabbatar da aikin lantarki da aminci.
Tsarin tsarin tanki: wannan ya haɗa da haɗa tanki, radiator, da tsarin sanyaya a cikin cikakken mahalli don ba da kariya mai kyau da keɓewa.
Tsarin Insulation: tara kariya da tsarin rufewa don tabbatar da cewa iska da sauran mahimman abubuwan an kiyaye su kuma an ware su.
Na'urar da ke cike mai: tabbatar da cewa an sanyaya na'urar taranfofi kuma an sanya shi a cikin ta hanyar allurar mai a cikin tankin mai.
03 Gwaji
a) Ba za a gudanar da gwaje-gwaje masu zuwa ba har sai an yi gwajin jiki da gwajin mikawa kamar yadda ake bukata.
b) A'a{0}}gwajin lodi kuma babu-gwajin rufewa na tasiri (mai sanyaya baya aiki)
① Dole ne a haɗa wutar lantarki zuwa wutar lantarki daga bangaren wutar lantarki, saboda gefen wutar lantarki yana sanye da na'urorin kariya don tabbatar da cewa an kashe wutar a cikin wani yanayi mara kyau.
② Canja lambobin siginar iskar gas na taswira zuwa da'irar da'ira na samar da wutar lantarki.
③ An saita ƙayyadadden lokacin kariyar wuce gona da iri azaman mataki na gaggawa.
④ Bayan an haɗa na'urar ta wuta zuwa layin da aka matsa, yakamata a ƙara ƙarfin wutar lantarki a hankali daga sifili zuwa ƙarfin lantarki na 1h, wanda a lokacin da injin ɗin bai kamata ya sami wani abu mara kyau ba.
⑤ Bayan gwajin da ke sama, yakamata a ƙara ƙarfin wutar lantarki a hankali zuwa sau 1.1 na ƙimar ƙarfin lantarki, kuma kada a kiyaye wani mummunan yanayi na mintuna 10, sannan a rage a hankali. Idan rukunin yanar gizon ba shi da sharuɗɗan ƙara matsa lamba a hankali, ana iya canza shi zuwa babu- zazzage gwajin gwajin awa 1, lokacin da babban zafin mai ya yi ƙasa da digiri 42 C, kar a fara fanan radiyo ko kar a saka mai sanyaya.
⑥ Ga mai kunnawa{0}}mai sarrafa na'ura mai sarrafa kaya, mai kunnawa -load tap{2}}ana sarrafa mai canza wutar lantarki a ma'aunin wutar lantarki na tsawon makonni biyu kuma a ƙarshe an daidaita shi zuwa matsayin mai canzawa-.
⑦ A'a{0}}gwajin tasirin tasirin rufewa.

04 Shiryawa da jigilar kaya
4.1 Shiryawa
1. Yi amfani da katako mai ƙarfi azaman tattarawa na waje, kuma shigar da abin girgizawa idan akwai, kamar kumfa, matashin iska, don rage tasirin girgizawa da tasiri akan samfurin.
2. Kare na'urar da kanta, ciki har da abubuwan da ke cikin mai canzawa, don hana girgizawa da yanayin waje akan tasirin samfurin.
3. A sarari alama nauyi, girman, tashar tashar adireshin adireshin da bayanin lamba akan kunshin.

4.2 Shipping

1. Mun zaɓi sufuri na teku saboda yana iya ɗaukar manyan kayan aiki kuma yana samar da ingantaccen yanayin sufuri.
2. A cikin zaɓar masu ɗaukar kaya, mun zaɓi ƙwararrun kamfanoni masu ƙwararru da ƙwararrun ƙwararrun don tabbatar da cewa samfuran za su iya isa cikin aminci da kan lokaci a inda aka nufa, da kuma kammala izinin kwastam.
05 Yanar Gizo da Takaitawa
Shiri: Bincika yanayin tushe da kayan aiki, gwajin gwaji, da shirya kayan aikin ɗagawa.
Ɗagawa: ɗaga ta amfani da wuraren da aka keɓe, daidaita injinan wuta, da amintattun kusoshi.
Na'urorin haɗi: Shigar da bushings, radiators, da sauran abubuwan haɗin gwiwa, tabbatar da hatimi da ɗaure daidai.
Cika Mai: Yi amfani da mai tsabtace mai don cika mai, duba matakin mai, da hatimi.
Gwaji: Gudanar da rufi, rabo, babu{0}} lodi, da gajerun gwaje-gwajen kewayawa.
Grounding: Shigar da tsarin ƙasa da juriya na gwaji.
Gudanarwa: Tabbatar da shigarwa, yi gwajin nauyi a hankali, kuma sanya aiki idan babu matsala.