2660 KVA Akwatin Canjin Waje-22.8 / 0.8 KV|Amurka 2025
Yawan aiki: 2660kVA
Wutar lantarki: 22.8/0.8kV
Fasalin: Ingantaccen DOE tare da sandunan bas na jan karfe
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'antun da masu samar da akwatin taswira na waje 2660 kva{6}}22.8/0.8 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Akwatin gidan wuta na waje yana isar da amintaccen, abin dogaro, kuma ingantaccen matsakaici{0}}wararrun wutar lantarki don abubuwan amfani na zamani da cibiyoyin sadarwa na masana'antu.
01 Gabaɗaya
1.1 Bayanin Aikin
A cikin 2025, wani abokin ciniki na Amurka ya ba da oda don a2660 kVA uku lokaci kushin saka transformer, An ƙirƙira don shigarwa cikin matsakaiciyar hanyar rarraba wutar lantarki ta hanyar sadarwa a cikin Amurka, inda aminci, aminci, da dogon lokaci{0} aiki na aiki ke da mahimmanci ga kayan aikin wutar lantarki. Transformer yana aiki azaman akwatin na'ura mai canzawa na waje, yana haɗa tankin na'ura mai canzawa, kayan aiki mai sauyawa, na'urorin kariya, da abubuwan haɗin wutar lantarki a cikin ƙaramin kumfa{2} da aka ɗora ya dace da hanyoyin rarraba kayan aiki da mahallin masana'antu. Bugu da ƙari, a matsayin wani ɓangare na oda iri ɗaya, abokin ciniki ya sayi ƙarami150 kVA kushin da aka saka tafsiridon samar da kayan taimako a cikin tsarin lantarki na aikin.
An ƙididdige naúrar a 2660 kVA, tare da babban ƙarfin lantarki na 22.8 kV da ƙarfin lantarki na biyu na 0.8 kV, kuma yana amfani da ƙungiyar vector YNd1, wanda ke goyan bayan barga uku - sauyin ƙarfin lantarki na lokaci; Ana kiyaye ƙayyadaddun ƙayyadaddun ƙaura da halayen ƙasa, kamar yadda ake buƙata don tsarin rarraba wutar lantarki na matsakaici. Wannan saitin yana saukar da matsakaicin mai amfani-ƙarfin wutar lantarki yadda ya kamata, yayin da yake isar da daidaitaccen wutar lantarki zuwa manyan lodin wutar lantarki{7}}mai dogaro, karko, kuma a shirye don haɗin grid.
An ƙirƙira shi da ƙera shi daidai da IEEE Std C57.12.34-2022, injin taswira ya bi ka'idodin Arewacin Amurka don kayan aikin da aka ɗora kushin, yana tabbatar da amintaccen aiki a cikin tsarin rarraba ƙasa da shigarwar waje inda fallasa muhalli da amincin aiki dole ne a sarrafa su a hankali.
1.2 Ƙayyadaddun Fasaha
2660kVA uku lokaci kushin saka gidan wuta ƙayyadaddun bayanai da takardar bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Uku fanni kushin Dutsen transformer
|
|
Daidaitawa
IEEE Std C57.12.34-2022
|
|
Ƙarfin Ƙarfi
2660 KVA
|
|
Yawanci
60HZ
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Mataki
uku
|
|
Nau'in Sanyi
KNAN
|
|
Liquid insulant
Farashin FR3
|
|
Babban Voltage
22.8 kV
|
|
Na biyu Voltage
0.8 kV
|
|
Ƙungiyar Vector
YNd1
|
|
Abubuwan Iska
Aluminum
|
|
Impedance
5.75%
|
|
inganci
DOE
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
2.5 kV
|
|
Akan Rasa Load
16.5 kV
|
|
Na'urorin haɗi
Garkuwar ƙasa
|
1.3 Zane
2660kVA uku lokaci kushin saka transformer zane da sunan farantin
![]() |
![]() |
02 Masana'antu
2.1 Tanki da Kaya

Kunshin da aka ɗora{0} tankin tasfoma cikakken tsari ne mai walƙiya, rufaffiyar tsari, an gina shi don ya zama mai ɗorewa kuma mai jurewa{1}}, dace da shigarwar waje. Ana tsare ƙofofin tare da ƙullun penta da 3-makulle vault; Ƙarshen farin foda mai rufi (RAL 9003) yana ba da juriya ga yanayin muhalli, lalata, da lalata UV.
2.2 Tsarin Insulation
Mai taswira yana ɗaukar FR3 ruwan insulation na ester na halitta. Gilashin firamare da na biyu na aluminium ne kuma an keɓe su don jure duka lokaci{2}}zuwa{3}}lokaci da lokaci{4}}zuwa{5}matsalolin wutar lantarki na ƙasa. Bugu da ƙari, naúrar tana da ƙaƙƙarfan garkuwar lantarki tsakanin iskar firamare da sakandare, wanda ke rage tsangwama mai girma{7}} da hauhawar wutar lantarki.

03 Tsarin Kulawa da Kariya
3.1 Kariya da Kula da Wutar Lantarki

Don tabbatar da aiki mai aminci da abin dogaro, injin rarraba wutar lantarki na matsakaici yana sanye da kayan sa ido da yawa da abubuwan kariya da aka haɗa a cikin shingen akwati na waje. Babban fasali sun haɗa da:
• Garkuwar electrostatic ta ƙasa
• Matsayin mai, zafin mai, da ma'aunin matsa lamba na tanki
• Bawul ɗin taimako na matsin lamba don kariyar wuce gona da iri
• Masu kamawa da yawa
• Sandunan bas na jan ƙarfe don haɗi zuwa fis na waje
• Load da masu juyawa
|
Na'ura |
Aiki |
|
Matsayin Matsayin Mai |
Yana lura da matakin mai |
|
Ma'aunin Yanayin Mai |
Yana lura da yanayin zafin aiki na transfoma |
|
Ma'aunin Matsalar Tanki |
Yana gano canje-canjen matsi na ciki |
|
Valve Taimakon Matsi |
Yana ba da kariya daga matsanancin matsin lamba na ciki |
Waɗannan kayan aikin sa ido suna ba da ganuwa mai ci gaba da aiki, ba da damar ƙungiyoyin kulawa don gano abubuwan da za su yuwu kafin su rikide zuwa gazawar aiki. Kulawa na rigakafi yana haɓaka aminci kuma yana tabbatar da dogon lokaci{1} kwanciyar hankali na cibiyoyin rarraba wutar lantarki na matsakaici. Bugu da ƙari, masu aiki za su iya amsawa da sauri ga yanayi mara kyau, rage raguwar lokaci.
3.2 Abubuwan Canjawa da Kariya
Transformer yana goyan bayan daidaitawa tare da abokin ciniki{0}}samar da na'urorin kariya na waje, gami da Eaton Bussmann High{1}}Speed Fuse 170M, wanda aka ƙera don samar da saurin amsawa ga kurakuran lantarki. Ƙungiyar ta ƙunshi:
• Uku biyu -matsayi masu ɗaukar nauyi
• Sandunan bas na jan ƙarfe don haɗin fuse
• Masu kamawa da yawa don walƙiya da kariyar wuce gona da iri

Wannan tsari yana ba da damar ɗorawa mai ɗawainiya da kushin lokaci uku don ware kurakuran wutar lantarki cikin aminci yayin kiyaye ci gaba ga ragowar hanyar sadarwar rarraba. Haɗaɗɗen sauyawa da kariya suna tabbatar da amsa kuskure cikin sauri, ingantaccen tsarin kariya, da isar da wutar lantarki mara katsewa, yana mai da akwatin canjin waje ya dace da aikace-aikacen PV{1} ma'auni da masana'antu na hasken rana.
04 Gwaji

Sakamakon Gwaji



05 Shiryawa da sufuri


06 Na Musamman Aikace-aikace
A matsayin akwatin wuta na waje, wannan kushin da aka ɗora wutar lantarki an ƙera shi don shigarwa a cikin wurare masu yawa na matsakaicin matsakaicin wutar lantarki na rarraba wutar lantarki, gami da tsarin wutar lantarki na masana'antu, kayan aikin amfani, wuraren samar da makamashi mai sabuntawa, da cibiyoyin rarraba kasuwanci inda ake buƙatar shigarwar taswirar waje mai aminci.
Aikace-aikace na yau da kullun sun haɗa da:
• Matsakaicin mai amfani{0}}tsarin rarraba wutar lantarki
• Rarraba wutar lantarki na masana'antu
• Wuraren makamashi masu sabuntawa, gami da gonakin PV na hasken rana
• Ayyukan ababen more rayuwa da kasuwanci
A cikin waɗannan mahalli, injin na'ura yana ba da ingantaccen jujjuyawar wutar lantarki yayin da yake riƙe babban amincin aiki, kuma yana ba da damar haɗawa cikin sauƙi tare da raka'o'in akwatin lantarki na taimako.
07 Yanar Gizo da Takaitawa

A cikin gabaɗayan kayan aikin lantarki na aikin, akwatin mai ɗaukar hoto na waje mai nauyin 2660 kVA yana aiki azaman babban matsakaicin matsakaicin wutar lantarki na rarraba wutar lantarki, mai canza matsakaicin mai amfani{1} ikon wutar lantarki zuwa matakin ƙarfin lantarki mai amfani don tsarin wutar lantarki na ƙasa yayin da yake tabbatar da aminci da kwanciyar hankali ta hanyar IEEE{2}} ƙira mai dacewa, tsarin rufewa na FR3, da kayan aikin kariya. Na'urar taswira ta samar da sashin wutar lantarki na tsakiya a cikin hanyar sadarwar rarraba aikin, kuma yana aiki tare da daidaitawa tare da akwatin lantarki na taimako na 150 kVA don tabbatar da abin dogaro, ci gaba da samar da wutar lantarki.
Hot Tags: akwatin wuta na waje, masana'anta, mai kaya, farashi, farashi
You Might Also Like
75 kVA 3 Mai Rarraba Rarraba Mataki-13.8 / 0.208 kV|...
225 kVA Kushin Dutsen Mai Canjawa-34.5 / 0.208 kV|Am...
5 MVA Pad Dutsen Masu Canzawa-33 / 0.48 kV|Amurka 2025
300 KVA Kushin Haɓaka Gidan Wuta-12.47*4.16/0.208 KV...
250 KVA Ƙananan Kushin Haɓakawa-13.8 / 0.22 KV|Guyan...
1000 KVA Kushin Haɓaka Mai Sauƙi Grounding-4.16 / 0....
Aika Aikace-aikacen