1000 KVA Kushin Haɓaka Mai Sauƙi Grounding-4.16 / 0.48 KV|Amurka 2025

1000 KVA Kushin Haɓaka Mai Sauƙi Grounding-4.16 / 0.48 KV|Amurka 2025

Kasar: Amurka 2024
Yawan aiki: 1000 kVA
Ƙarfin wutar lantarki: 4.16D-0.48Y/0.277 kV
Feature: tare da bawul na Schrader
Aika Aikace-aikacen

 

image001

Pad -Masu Sauƙaƙe: Inda Tsaro Ya Hadu Sauƙi.

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

1000 kVA uku fanti pad mounted transformer aka kawo wa Amurka a 2024. Ƙimar ikon na'urar shine 1000 kVA tare da ONAN sanyaya. Babban ƙarfin lantarki shine 4.16D kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.48Y / 0.277 kV, sun kafa ƙungiyar vector na Dyn1.

The Pad{0}Mounted Transformer wani muhimmin abu ne kuma abin dogaro na tsarin rarraba wutar lantarki na zamani, wanda aka ƙera don a amince da saukar da babban ƙarfin lantarki zuwa ƙarancin wutar lantarki da gidaje, kasuwanci, da wuraren jama'a ke buƙata.

An lullube shi a cikin kulle-kulle, tamper{0}}arfe mai juriya, shine ginshiƙin hanyoyin sadarwar wutar lantarki na ƙasa, wanda ya dace da yankunan zama, wuraren kasuwanci, da shimfidar wurare na birane inda kayan ado da amincin jama'a ke da mahimmanci. Ƙananan ƙirar bayanin sa{2} yana rage tasirin gani yayin samar da aiki mai ƙarfi.

Maɓalli masu mahimmanci sun haɗa da tsayin daka na musamman don jure matsananciyar yanayin muhalli, mai amfani{0}}amintaccen aiki don ma'aikatan mai amfani, da sauƙi mai sauƙi don kulawa. An ƙirƙira shi na dogon lokaci{2}amintacce da inganci, kushin{3} da aka ɗora tasfoma yana isar da shiru, ƙarfi mara yankewa wanda al'ummomi suka dogara da shi, yana mai da shi amintaccen hanyar haɗin yanar gizo tsakanin grid mai amfani da ƙarshen mai amfani-.

 

 

 

1.2 Ƙayyadaddun Fasaha

1000 kVA kushin da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai

Isarwa zuwa
Amurka
Shekara
2024
Nau'in
Tashin wutar lantarki
Daidaitawa
IEEE Std C57.12.34-2022
Ƙarfin Ƙarfi
1000 kVA
Yawanci
60HZ
Mataki
3
Ciyarwa
Madauki
Gaba
Matattu
Nau'in Sanyi
ONAN
Babban Voltage
4.16d kV
Na biyu Voltage
0.48Y/0.277 kV
Abubuwan Iska
Aluminum
Ƙungiyar Vector
Dyn1
Impedance
5.75%
inganci
99.43%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
1.3 kW
Akan Rasa Load
6.94 kW

 

1.3 Zane

1000 kVA kushin da aka ɗora zane da girman hoto.

image003 image005

 

 

02 Masana'antu

2.1 Kori

image007

Jikin mu yana amfani da babban nau'in hatsi{0}{1}}madaidaicin silikon zanen karfe da madaidaicin matakin -Lap lamination. Yana rage asara - da kashi 15% idan aka kwatanta da matsakaicin masana'antu (Yana rage farashin wutar lantarki) kuma yana rage hayaniya/firgita (ƙananan kulawa). Ƙuntataccen gwajin bayarwa{7} yana tabbatar da dogaro, yana nuna ƙarfin R&D ɗinmu da ƙarfin masana'anta don biyan buƙatar dacewa da ƙimar ku.

 

2.2 Guda

Sami darajar mafi girma tare da aluminium ɗin mu{0}}arauni. Haɗin HV foil da haɗin waya na LV yana ba da tabbataccen tabbaci ga grid ɗin ku, kai tsaye yana rage farashin rayuwa da haɗarin rashin lalacewa.

image009

 

2.3 Tanko

image011

Tankin yana da ingantaccen ƙirar sanyaya wanda ke tabbatar da ƙarancin yanayin aiki. Wannan kai tsaye yana tsawaita rayuwar sabis na taransfoma kuma yana haɓaka iyawa fiye da kima, yana ba da kariya ga jarin ku tare da tabbataccen, dogon aiki mai tsawo-.

 

2.4 Taron Karshe

An tsara na'urorin mu na lantarki don shigarwa mai sauri da sauƙi. Dukkan abubuwan ciki da na waje an riga an gwada su kuma an riga an haɗa su azaman cikakke, haɗin gwiwa. Wannan yana ceton ku lokaci mai mahimmanci da farashin aiki yayin turawa yayin da yake tabbatar da daidaito, matsala{4}}aiki kyauta a tsawon tsawon rayuwar samfurin.

image013

 

 

03 Gwaji

Mu 1000kVA guda uku -fasalin kushin{2}}saka tafsiri (4160Δ{7}}480Y/277V, serial 241204) yayi fice daga masu fafatawa tare da IEEE{12}} masu daidaitawa (C57.12.00/34/90} 277) abokin ciniki{27}}sakamakon mayar da hankali. Mahimman ma'auni: 2.93% max juriya rashin daidaituwa (yana guje wa zafi fiye da kima, yana yanke kiyayewa), - 0.13% bambancin ƙarfin lantarki (yana tabbatar da kwanciyar hankali na ƙasa), 1.289kW babu kaya / 7.223kW asarar nauyi (a cikin ± 10% / ± 6% haƙuri don tanadin makamashi 1.G-3). (hana kuskuren lantarki), 19kV HV / 10kV LV jure gwaje-gwaje (60s, babu rugujewar wutar lantarki don aminci), 12-hour 20kPa gwajin kyauta (yana kawar da farashin maye gurbin mai), da ƙarfin dielectric mai 54.9kV (yana garantin dogon lokaci).

A'a.

Gwajin Abun

Naúrar

Karba

Darajoji

Ƙimar Ma'auni

Kammalawa

1

Ma'aunin Juriya

%

Matsakaicin juriya rashin daidaituwa

2.93

Wuce

2

Gwajin Rabo

%

Bambancin rabon ƙarfin lantarki akan babban tapping: ƙasa da ko daidai da 0.5%

-0.13

Wuce

3

Mataki{0}}gwajin dangantaka

/

Dyn1

Dyn1

Wuce

4

A'a -asara da tashin hankali na halin yanzu

%

I0 :: bayar da ma'auni darajar

0.43

Wuce

kW

P0: Bayar da ƙima (digiri 85)

1.289

/

Haƙuri don asarar nauyi shine ± 10%

/

5

Load asarar , impedance ƙarfin lantarki, jimlar asara da kuma yadda ya dace

/

t:85 ku

haƙuri ga impedance shine ± 7.5%

Haƙuri don asarar nauyi shine ± 6%

/

Wuce

%

Z%: ƙimar da aka auna

5.42

kW

Pk: ƙimar ƙima

7.223

kW

Pt: ƙima mai ƙima

8.451

%

Ingancin ba kasa da 99.43%

99.43

6

Gwajin Karfin Wutar Lantarki

/

HV: 19kV 60s

LV: 10kV 60s

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

7

Jarrabawar Juriya da Wutar Lantarki

/

Wutar lantarki mai aiki (KV): 0.96

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

Duration(s):48

Mitar (HZ): 150

8

Ma'aunin Resistance Insulation

HV{0}LV zuwa Kasa:

20.8

/

LV -HV zuwa Ground:

31.0

HV&LV zuwa Ground:

19.4

9

Gwajin Leaka

/

matsa lamba: 20kPA

Babu yabo kuma babu

Lalacewa

Wuce

Tsawon lokaci: 12h

10

Gwajin Mai

kV

Ƙarfin Dielectric

54.9

Wuce

mg/kg

Abubuwan Danshi

9.7

%

Factor Dissipation

0.00227

mg/kg

Furan Analysis

/

/

Gas Chromatography Analysis

/

 

image015
image017

 

 

04 Shiryawa da jigilar kaya

4.1 Shiryawa

image019

Don kushin mu guda uku{0}}{1} masu hawa tafsiri, marufi yana ba da fifikon buƙatunku: jakunkuna na foil na aluminium (tare da kayan bushewa don hana lalacewar danshi) + masu kariyar kusurwa + lamban akwatunan katako (forklift/tsakiyar-na-alamar nauyi). Ba mu tsallake matakai, don haka za ku sami tsatsa kyauta, ba tare da lalacewa ba tare da wahala{8}}kyauta akan gudanar da rukunin yanar gizo.

 

4.2 Shipping

Muna ba da sabis ɗin CIF maras kyau, damuwa{0} kyauta har zuwa tashar jiragen ruwa na Los Angeles. Kwarewar mu game da kayan aikin canji da ingantaccen ɗaukar hoto yana nufin muna sarrafa duk haɗarin wucewa da ka'idojin kwastam. Kuna amfana daga batu guda na lissafin kuɗi, tabbatar da isarwa mai santsi, abin dogaro wanda ke kare tsarin lokacin aikin ku da saka hannun jari.

image021

 

 

05 Yanar Gizo da Takaitawa

Cibiyar rarraba ku tana buƙatar abokin tarayya, ba kawai mai bayarwa ba. Tasfoman da aka ɗora kushin mu suna wakiltar cikakkiyar mafita, tare da goyan bayan ƙwarewar fasaha da sadaukarwar ku ga nasarar ku. Muna ba da fa'idodi masu ma'ana waɗanda kuke buƙata: ƙirar samfura mafi inganci, kayan aiki mara nauyi, da goyan baya mara kaushi. Zaɓi mu don haɗin gwiwa wanda ke haifar da haɗarin saka hannun jari kuma yana ba da ƙima mara ƙima daga ƙayyadaddun bayanai zuwa sabis.

image023

 