1000 KVA Rarraba Kushin Dutsen Mai Canjawa-12.47 / 0.48 KV|Amurka 2025

1000 KVA Rarraba Kushin Dutsen Mai Canjawa-12.47 / 0.48 KV|Amurka 2025

Ƙasar Bayarwa: Amurka 2025
Yawan aiki: 1000kVA
Wutar lantarki: 12.47/0.48 KV
Feature: FR3 Oil & DOE inganci
Aika Aikace-aikacen

Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin mafi amintattun masana'antun da masu samar da 1000 kva rarraba kushin dutsen wutan lantarki{6}}12.47/0.48 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

 

1000 kva distribution pad mount transformer-front-door-open

Amintacce, makamashi{0}ingantaccen kushin-madaidaicin kushin rarraba wutar lantarki, wanda aka ƙera don amintaccen, sassauƙa, da matsakaici mai dorewa{2}}zuwa{3}}arancin wutar lantarki.

 

 

01 Gabaɗaya

1.1 Fassarar Ayyukan & Maɓalli Maɓalli

A cikin 2025, babban aikin samar da wutar lantarki na Amurka ya buƙaci shigar da wani1000 kVA guda uku{1}don samar da tsayayye, ingantaccen jujjuyawar wutar lantarki don kasuwanci da ƙananan na'urorin lantarki{0}}. Wannan rukunin yana aiki tare da matsakaici{2}} cibiyoyin rarraba wutar lantarki kuma yana tabbatar da dacewa tare da abubuwan more rayuwa, yana mai da shi mafita mai kyau don canjin wutar lantarki na gida.

Mabuɗin fasali:

• Ƙarfin ciyarwar madauki: yana ba da damar haɗin kai zuwa cibiyar sadarwar rarraba zobe, inganta ci gaba da wutar lantarki da kuma ba da fadada cibiyar sadarwa mai sassauƙa don rarraba kushin dutsen wuta.
• Yarda da ingancin makamashi na DOE: yana rage asarar aiki, rage tsadar makamashi a tsawon rayuwar na'ura.
• FR3 na halitta ester insulating ruwa: biodegradable, high wuta -manufa rufi, tsawaita rayuwar sabis da kuma inganta muhalli aminci.
• M foda mai rufi farin yadi (RAL 9003): lalata juriya, UV kariya, da kuma tsabta waje bayyanar ga waje rarraba kushin Dutsen transformer shigarwa.
 

 

 

1.2 Ƙayyadaddun Fasaha

1000kVA uku lokaci kushin saka gidan wuta ƙayyadaddun bayanai da takardar bayanai

Isarwa zuwa
Amurka
Shekara
2025
Nau'in
Uku fanni kushin Dutsen transformer
Daidaitawa
IEEE Std C57.12.34-2022
Ƙarfin Ƙarfi
1000 KVA
Yawanci
60HZ
Ciyarwa
Madauki
Gaba
Matattu
Mataki
uku
Nau'in Sanyi
KNAN
Liquid insulant
Farashin FR3
Babban Voltage
12.47D
Na biyu Voltage
0.48Y/0.277kV
Ƙungiyar Vector
Dyn1
Abubuwan Iska
Aluminum
Impedance
5.75%
inganci
DOE
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
1.3 kW
Akan Rasa Load
6.94 kW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

1000kVA uku lokaci kushin saka transformer zane da sunan farantin

1000 kva distribution pad mount transformer-outline-drawing 1000 kva distribution pad mount transformer-nameplate

 

 

02 Zane da Siffofin Tsari

2.1 Uku -Mataki na Uku{2}}Ƙashin Ƙaƙwalwa

1000 kva distribution pad mount transformer-steel-core
1000 kva distribution pad mount transformer-amorphous-core

Taswirar tana da nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan nau'ikan silicon da aka gina. Madaidaicin tari yana rage girman asara, girgizawa, da amo yayin da yake riƙe da daidaiton motsin maganadisu. Wannan tsarin yana tabbatar da dogon lokaci{7} dogayen dogayen na'urorin watsa wutar lantarki a cikin matsakaicin matsakaicin ci gaba{8}}ƙarashin wutar lantarki.

 

2.2 Aluminum Winding System

1000 kva distribution pad mount transformer-winding
1000 kva distribution pad mount transformer-transformer-windings

Aluminum windings tare da high -zazzabi rufaffiyar samar da ingantacciyar ma'auni na aiki, ƙarfi, da nauyi don ƙaramin kushin{1}} ɗora ƙirar wuta. Ana tattara coils ɗin a hankali kuma an ƙarfafa su ta hanyar injiniyanci, inganta amincin rufi da haɓaka juriya ga gajerun rundunonin kewayawa yayin yanayi mara kyau.

 

2.3 FR3 Tsarin Kulawa da Sanyaya

1000 kva distribution pad mount transformer-oil-tank

Wannan na'urar taswira tana amfani da ruwa na ester na halitta na FR3, wanda ke iya lalata, yana da babban wurin wuta, kuma yana ba da juriya mai inganci idan aka kwatanta da mai. Hanyar sanyaya ta KNAN ta haɗu da kewayawar mai na halitta tare da iskar iska ta yanayi, kiyaye yanayin aiki mai ƙarfi ba tare da ƙarin kayan sanyaya ba, tabbatar da cewa mai rarraba kushin dutsen wuta yana aiki da kyau.

 

2.4 Kunshin - Wurin da aka ɗora

Kunshin -wajen da aka ɗora yana amfani da matacciyar ƙira ta gaba don kare ma'aikata daga hulɗar bazata tare da sassan da ke da kuzari. Ƙaƙƙarfan majalisar ministocin waje yana ɗaukar abubuwan da suka haɗa taswira, kayan sauya kayan aiki, da na'urorin kariya a cikin ingantaccen tsari wanda ya dace da kayan aiki ko shigarwar masana'antu.

1000-kva-distribution-pad-mounted-transformer-lead-handling-active-part

 

 

03 Ayyuka & Abubuwan Kariya

1000-kva-distribution-pad-mounted-transformer-Standard Monitoring & Protection Accessories

Rarraba kushin Dutsen wutan lantarki ya haɗa da cikakken tsari na kariya da fasalulluka don tabbatar da aiki mai aminci:

• Matattu{0}}tsarin aminci na gaba
• Garkuwar electrostatic ta ƙasa
• Kariyar fuse
• Hudu - maɓalli na ɗaukar nauyi
• Ma'aunin mai da kula da yanayin zafi

 

 

04 Shiryawa da jigilar kaya

4.1 Shiryawa

1000 kva distribution pad mount transformer-vacuum-packaging-in- aluminum-foil-bag
1000 kva distribution pad mount transformer-export-packing

 

05 Yanayin Aikace-aikacen

1000 kVA kushin da aka ɗora mai rarraba kushin ɗorawa mai canzawa shine manufa don:

• Gine-ginen ofisoshin kasuwanci
• Taro na masana'antu da masana'antu
• Cibiyoyin bayanai da wuraren IT
Ƙaƙƙarfan kushinsa{0}}ƙirar da aka ɗora, ingancin DOE, da kuma FR3 rufi yana ba da abin dogaro, sassauƙa, da rarraba mahalli na matsakaici{2}}ƙarfin wutar lantarki zuwa ƙananan tsarin wutar lantarki{{3}. Wannan rarraba kushin Dutsen wutan lantarki yana tabbatar da tsayayye da ci gaba da ƙarfi don kayan taimako da mahimmanci.

 