500 kVA Kushin Haɓaka Mai Canjin wurin zama-34.5 / 0.48 kV|Guyana 2024

500 kVA Kushin Haɓaka Mai Canjin wurin zama-34.5 / 0.48 kV|Guyana 2024

Ƙasa: Kudancin Amirka 2024
Yawan aiki: 500kVA
Wutar lantarki: 34.5/0.48kV
Feature: tare da schrader bawul
Aika Aikace-aikacen

 

 

pad mounted residential transformer

Makamashi{0}}mai inganci kuma mai sauƙin kiyayewa, mafi kyawun abokin aikinku{1}}uku{2}kushin lokaci{3}}masu wutan lantarki!

 

01 Gabaɗaya

1.1 Fagen Aikin

500 kVA pad mounted transformer an isar da ita zuwa Kudancin Amurka a cikin 2024. Ƙarfin wutar lantarkin shine 500 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 34.5GRDY / 19.92kV tare da ± 2 * 2.5% tapping range (NLTC), ƙarfin lantarki na biyu shine 0.48 / 0.277kV, sun kafa ƙungiyar vector na YNyn0, kuma shine madaidaicin ciyarwa. Saboda mafi girman aminci da amincin tampers{12}}hujja masu ɗorawa, sun dace don amfani da su a wuraren da jama'a za su iya taɓa su, ko kuma a kowane yanayi da ake buƙatar igiyoyi na ƙarƙashin ƙasa.

 

1.2 Ƙayyadaddun Fasaha

500 kVA nau'in ƙayyadaddun bayanai da takaddun bayanai

Isarwa zuwa
Kudancin Amurka
Shekara
2024
Nau'in
Tashin wutar lantarki
Daidaitawa
IEEE Std C57.12.34-2022
Ƙarfin Ƙarfi
500kVA
Yawanci
60HZ
Mataki
3
Nau'in Sanyi
ONAN
Babban Voltage
34.5GRDY/19.92 kV
Na biyu Voltage
0.48Y/0.277 kV
Abubuwan Iska
Aluminum
Matsala ta kusurwa
YNyn0
Impedance
4%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
1.02KW
Akan Rasa Load
5.55KW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

500 kVA kushin da aka ɗora zane da girman hoto.

20250409144203 20250409144252

 

 

02 Masana'antu

2.1 Kori

Uku{0}sashi na biyar{1} ginshiƙi na ginshiƙi na ci-gaba ne na ginshiƙi na transfoma, tsarinsa ya ƙunshi ginshiƙan ferromagnetic guda biyar, ginshiƙai{2} guda uku da ginshiƙai guda biyu na gama gari suna ba da ƙayyadaddun tsari na geometric. Babban fa'idar wannan ƙira shine cewa yana iya rage asarar hysteresis yadda yakamata da asara na yanzu, ta haka inganta ingantaccen injin na'urar.

Ingantacciyar hanyar juzu'i na ginshiƙi{{0}phase biyar-column core yana sa rarrabawar jigon ya zama iri ɗaya kuma yana rage haɗarin saturation na gida. Wannan ba kawai yana inganta ƙarfin lodin na'urar ba, har ma yana haɓaka ƙarfinsa zuwa saurin grid. Bugu da ƙari, zane yana rage tsangwama na lantarki, yana taimakawa wajen inganta kwanciyar hankali da amincin kayan aiki.

advanced transformer core design

 

2.2 Guda

transformer input voltage

Nadin na’urar na’urar na’ura na daya daga cikin muhimman abubuwan da ke tattare da shi, wanda ke da alhakin watsawa da juyar da makamashin lantarki. Yawanci ana rarraba shi zuwa manyan naɗaɗɗen wutan lantarki da ƙananan na'urorin lantarki, duka biyun suna haɓaka ko rage ƙarfin wutar lantarki ta hanyar haɗin filin maganadisu. An raunata magudanar ruwa daga kayan aiki (kamar jan ƙarfe ko aluminum) tare da ingantaccen ƙarfin lantarki da juriya na zafi don tabbatar da aiki mai ƙarfi a ƙarƙashin yanayi daban-daban.

A cikin ƙira, jujjuyawar jujjuyawar wutar lantarki kai tsaye tana shafar rabon wutar lantarki na taransfoma, wato, ƙimar adadin jujjuyawar babban ƙarfin wuta da ƙaramin ƙarfin wutar lantarki yana ƙayyadad da dangantakar da ke tsakanin ƙarfin shigarwa da ƙarfin fitarwa. Bugu da ƙari, tsarin ƙirar na'urar, yanayin iska da kuma zaɓin kayan haɓakawa kuma suna da tasiri kai tsaye a kan aikin, inganci da ƙarfin zafi na mai canzawa.

 

2.3 Tanko

Tankin na’urar taranfoma wani muhimmin bangare ne na na’urar taranfoma, wadda aka fi amfani da ita wajen taskance mai, kuma tana taka rawa wajen sanyaya da kariya. Yawanci ana yin tanki ne da ƙarfe kuma yana da ƙarfi mai kyau da juriya na lalata don tabbatar da kwanciyar hankali da amincinsa a wurare daban-daban na aiki. The insulating man da aka adana a ciki ba zai iya kawai yadda ya dace, amma kuma yana da kyakkyawan yanayin tafiyar da zafi, wanda zai iya saurin kawar da zafin da na'urar ta canza yayin aiki, ta yadda za a kula da yanayin zafin na'urar.

A cikin ƙira, tanki yawanci yana da masu haɗawa da yawa da bawuloli don sauƙaƙe saka idanu kan matakin mai da zafin jiki da aiwatar da kulawar da ya dace. Bugu da kari, wasu tankuna kuma suna sanye da na'urorin sakin iskar gas don tinkarar bala'i kamar fadada iskar gas na cikin gida ko zubewa, wanda ke inganta amincin injin na'urar.

Zane-zanen hatimin tankin yana da mahimmanci, wanda zai iya hana kutsawa daga danshi da ƙazanta, tsawaita rayuwar mai hana ruwa, da tabbatar da tsayin daka{0}} na aikin na'urar. Ta hanyar ƙirar tanki mai ma'ana, ba wai kawai zai iya haɓaka inganci da amincin na'urar ta atomatik ba, har ma da yadda ya kamata rage farashin kulawa da haɓaka aikin gabaɗaya na kayan aiki.

bunded oil storage tanks

 

2.4 Taron Karshe

oil temperature indicator

Majalisa: Haɗa core da windings, kuma shigar da kayan rufewa.

Tankin mai: Shigar da tankin mai kuma ƙara mai insulating.

Na'urar Rarrabawa: Haɗa manyan na'urorin rarraba wutar lantarki.

Kasa: Shigar da tsarin ƙasa.

 

 

03 Gwaji

1. Gwajin juriya na DC.

2. Gwajin juriya na insulation.

3. Ma'auni na ƙarfin lantarki da ƙungiyar vector.

4. Rarrabe tushen AC jurewar gwajin ƙarfin lantarki.

5. Induced AC jure ƙarfin lantarki gwajin.

6. Ma'auni Babu -asara kuma babu kaya a halin yanzu.

7. Ma'auni nauyi da impedance.

8. Resistance hasara da inganci.

9. Gwajin hatimi.

 

Measurement load and impedance
DC resistance test

 

 

04 Shiryawa da jigilar kaya

pad mounted residential transformer packing
pad mounted utility transformer shipping

 

 

05 Yanar Gizo da Takaitawa

A taƙaice, an ƙera tafsirin mu guda uku{0}}saidai{1} don biyan buƙatun rarraba wutar lantarki a sassa daban-daban. Ƙarfin gininsa, haɗe tare da fasahar ci gaba, yana tabbatar da aminci da inganci wajen isar da wutar lantarki. Wannan taswirar ba kawai tana goyan bayan tsarukan wutar lantarki masu girma{4} ba amma kuma yana jaddada aminci da alhakin muhalli. Ta hanyar zabar kushin mu guda uku -madaidaitan mu-wanda aka ɗora tasfoma, kuna yin dabarun saka hannun jari a cikin mafita wanda ke haɓaka ingantaccen aiki da haɓaka ayyuka masu dorewa. Kasance tare da mu don samar da kyakkyawar makoma mai haske, mai dorewa tare da fasahar mu na yanke{9}} gefuna.

pad mounted utility transformer

 