2500 kVA Kushin Haɗa Mai Canjawa-13.2 / 0.48 kV|Kanada 2024
Yawan aiki: 2500kVA
Wutar lantarki: 13.2/0.48kV
Feature: tare da IFD

Ƙarfin kaya mai girma, 24/7 kariya - Uku -Pad Pad{4}Mounted Transformer, wanda aka ƙera don buƙatun wutar lantarki na zamani!
01 Gabaɗaya
1.1 Fagen Aikin
Wannan 2500 kVA Pad mounted transformer an isar da ita zuwa Kanada a cikin 2024. Ƙarfin da aka ƙididdige na na'urar shine 2500 kVA, tare da babban ƙarfin lantarki 13.2GrdY/7.62 kV zuwa ƙarfin lantarki na biyu 0.48GrdY/0.277 kV. The connection group is YNyn0, pad mounted transformer shine don inganta haɗin mai - immersed sealed power transformer da high and low voltage electronic components, ta hanyar inganta tsarin, da switchgear an miniaturized kamar yadda zai yiwu, ƙwarai rage sawun na a hade transformer, da girma ne kawai daidai da guda ikon, 1/5 akwatin na Turai yana da ƙarami canji. amo, abin dogaro da wutar lantarki, ingantaccen tsari, sassauƙan shigarwa, aiki mai sauƙi, da matsakaicin shiga cikin cibiyar ɗaukar nauyi. Ana amfani da shi sosai a wuraren zama, cibiyoyin kasuwanci, tashoshi, masana'antu da masana'antar hakar ma'adinai, filayen jirgin sama, layin dogo, makarantu, asibitoci, manyan gine-gine masu tasowa da sauran wurare. Na'urar taswira ta Amurka tana ɗaukar kariya ta fuse sau biyu, kuma filogi{17}}a cikin fuse (BAY-O-NET) shine gajeriyar kuskuren kewayawa da ke faruwa a gefen biyu na akwatin kariyar fiusi biyu (zazzabi, halin yanzu). Akwatin kariya na iyakance iyaka na yanzu (ELSP) yana canza kurakuran ciki, ana amfani da shi don kare gefen babban ƙarfin lantarki.
1.2 Ƙayyadaddun Fasaha
2500 kVA nau'in ƙayyadaddun bayanai da takaddun bayanai
|
Isarwa zuwa
Kanada
|
|
Shekara
2024
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
IEEE C57.12.00
|
|
Ƙarfin Ƙarfi
2500 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
ONAN
|
|
Babban Voltage
13.2GrdY/7.62kV
|
|
Na biyu Voltage
0.48/0.277 kV
|
|
Abubuwan Iska
Aluminum
|
|
Matsala ta kusurwa
YNyn0
|
|
Impedance
5.75±7.5%
|
|
inganci
99.53%
|
|
Matsa Canji
Farashin NLTC
|
|
Liquid Insulant
Ma'adinai mai
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
Kasa da ko daidai da 2.3KW
|
|
Akan Rasa Load
Kasa da ko daidai da 16.2KW
|
|
Na'urorin haɗi
Daidaitaccen Kanfigareshan
|
1.3 Zane
2500 kVA kushin da aka ɗora zane da girman hoto.
![]() |
![]() |
02 Masana'antu
2.1 Kori
Rukunin guda uku{0}sashi na biyar-lamin ƙarfen ƙarfe na ginshiƙi na iya rage asarar ƙarfe da hayaniya yadda ya kamata, kuma tsarin rukunin guda uku{2}sashi na biyar{3} zai iya samar da mafi daidaiton rabon maganadisu, haɓaka ƙarfin ƙarfin ƙarfin ƙarfen ƙarfe zuwa filin maganadisu, kuma yana taimakawa inganta ingantaccen aiki da aikin kayan aiki. Tsarin laminated yana taimakawa wajen inganta aikin watsawar zafi na ainihin, rage yawan zafin jiki, hana zafi, da kuma tsawaita rayuwar kayan aiki.

2.2 Guda

Babban ƙarfin lantarki
ZGS jerin high irin ƙarfin lantarki tashoshi suna sanye take da high irin ƙarfin lantarki bushing guda ko biyu) amfani da su gama gwiwar hannu irin na USB toshe ko gwiwar hannu irin cikakken insulated arrester, da live part aka shãfe haske a cikin rufi jiki, forming wani cikakken rufi tsarin, da m surface ba a caje, (kasa m), don tabbatar da sirri aminci. A cikin yanayin gaggawa, ana iya shigar da filogin na USB a ciki da waje lokacin da na'urar ta jujjuyawar ta cika. Saboda wannan dalili, filogin na USB kuma na iya aiki azaman maɓalli na kaya. Ana iya shigar da nuni kai tsaye ko alamar kuskure akan filogin kebul kamar yadda ake buƙata. A bango Dutsen da aka welded a gaban babban babban na'ura mai canzawa tanki high matsa lamba kusa da babban matsa lamba bushing, wanda ake amfani da gyara configurable support irin insulating bushing shugaban. Lokacin da filogin kebul ɗin ke kunne, ana iya shigar da shi nan da nan cikin haɗin gwiwa irin na goyan baya.
Ƙananan ƙarfin lantarki
Akwai ƙananan tashoshi masu fitar da wutar lantarki masu ƙanƙanta -a cikin ƙaramin tazarar wutar lantarki, da ƙaramin{2}}ƙananan na'urar keɓewar wutar lantarki da na'urar keɓewar reshe, ƙaramin{3}}ƙarashin wutar lantarki, mita ƙarfin lantarki da na'urar ramuwa ta atomatik ana bayar da ita kamar yadda ake buƙata. Za a iya shigar da fan axial a saman ƙananan tazarar ƙaramar wutar lantarki bisa ga buƙatun mai amfani, kuma kayan aikin sarrafa zafin jiki na musamman na iya sarrafa zafi ta fanti ta atomatik gwargwadon yanayin zafi a cikin tazarar. Za'a iya shigar da na'urar wayar hannu idan an buƙata. Haɗe-haɗen gwajin rarrabuwa tare da aikin sadarwa mai nisa, wanda aka ƙara shi da ƙananan ƙarfin lantarki da ƙasan{9}} mai sarrafa wutar lantarki, zai iya gane aikin kariyar babu{10}}ƙara da ƙarfin lantarki a ƙarƙashin{12}}ƙarashin wutar lantarki, wanda zai iya guje wa lalacewa ga masu canza wuta da lodin kayan lantarki.
2.3 Tanko
Bisa ga zane-zane na zane, an yanke farantin karfe zuwa nau'i daban-daban da siffofi don haɗuwa na gaba. Yankan hanyoyin na iya zama CNC sabon na'ura, Laser sabon ko oxygen sabon. An lanƙwasa farantin karfe da aka yanke, da gurɓatacce da sauran matakai don samar da sassa daban-daban na tanki, kamar farantin ƙasa, farantin gefe, farantin saman, da dai sauransu. Bayan waldawa, wajibi ne a gudanar da bincike na bayyanar da kuma tantance girman girman don tabbatar da cewa an cika buƙatun ƙira. Bayan kammala walda, ana kula da saman tanki don hana lalata da tsatsa. Hanyoyi na gama gari sun haɗa da ɓarkewar yashi, yashi da ɓata ruwa, sannan shafaffe da fenti ko fenti na hana lalata-. Akwatin yana ɗaukar ƙirar lalata da kuma maganin fentin fenti na musamman, wanda za'a iya amfani da shi zuwa wurare daban-daban, kamar guguwa da yawa da wuraren ƙazanta.

2.4 Taron Karshe


03 Gwaji
|
A'a. |
Gwajin Abun |
Naúrar |
Dabi'un Karɓa |
Ƙimar Ma'auni |
Kammalawa |
|
1 |
Ma'aunin Juriya |
% |
Matsakaicin rashin daidaiton juriya Kasa da ko daidai da 5% |
3.28 |
Wuce |
|
2 |
Gwajin Rabo |
% |
Bambancin rabon ƙarfin lantarki akan babban tapping: ƙasa da ko daidai da 0.5% Alamar haɗi: YNyn0 |
-0.02% ~ -0.01% |
Wuce |
|
3 |
zango{0}}gwajin dangantaka |
/ |
YNyn0 |
YNyn0 |
Wuce |
|
4 |
A'a -asara da tashin hankali na halin yanzu |
% kW |
t:20 digiri I0: bayar da ma'auni darajar P0: ba da ƙima mai ƙima juriyar rashin hasara shine +10% |
0.25 2.354 |
Wuce |
|
5 |
Load hasarar impedance ƙarfin lantarki da inganci |
% kW kW |
t:85 ku Z%: ƙimar da aka auna Pk: ƙimar ƙima Pt: ƙima mai ƙima Haƙuri don impedance shine ± 7.5% Haƙuri don jimlar asarar kaya shine +6% Ingancin ba kasa da 99.53% |
5.85 15.580 17.934 99.53 |
Wuce |
|
6 |
Gwajin Karfin Wutar Lantarki |
kV |
HV&LV: 10kV 60s |
Babu rushewar ƙarfin gwajin da ke faruwa |
Wuce |
|
7 |
Jarrabawar Juriya da Wutar Lantarki |
kV |
Wutar lantarki mai aiki (KV): 26.4 Duration(s): 40 Mitar (HZ): 150 |
Babu rushewar ƙarfin gwajin da ke faruwa |
Wuce |
|
8 |
Gwajin Leaka |
kPa |
matsa lamba: 20kPA Tsawon lokaci: 12h |
Babu yabo kuma babu Lalacewa |
Wuce |
|
9 |
Ma'aunin Resistance Insulation |
GΩ |
HV&LV zuwa Ground: |
8.68 |
/ |
|
10 |
Gwajin Dielectric Oil |
kV |
Yafi ko daidai da 45 |
53.80 |
Wuce |
|
11 |
Gwajin surutu |
dB |
51-55 |
57.3 |
Wuce |
|
12 |
Gwajin bugun walƙiya |
kV |
cikakken igiyar ruwa, Rabin igiyar ruwa |
Babu rushewar ƙarfin gwajin da ke faruwa |
Wuce |


04 Shiryawa da jigilar kaya


05 Yanar Gizo da Takaitawa
A ƙarshe, Mai Canjin Canjin Mataki na Uku na Pad ya fito fili don ingantaccen ingancin sa, aminci, da dorewa, yana mai da shi yaɗuwa a cikin ayyukan kasuwanci, masana'antu, da ayyukan jama'a. Ko don babban aikin rarraba wutar lantarki mai girma{1} ko aiki mai ƙarfi a cikin hadaddun mahalli, wannan samfurin yana ba da ingantattun mafita don tallafawa ingantaccen sarrafa makamashi da fa'idodin tattalin arziki na dogon lokaci. Zaɓi Canjin Canjin Mataki na uku don ƙarfafa ayyukan ku da ba da gudummawa ga koren makamashi mai inganci a nan gaba.