750 kVA Liquid Cika Masu Canji-12.47 / 0.6 kV|Amurka 2025
Yawan aiki: 750kVA
Wutar lantarki: 12.47/0.6kV
Fasalin: FR3 mai & mai kama gwiwar hannu

Eco{0}}amintaccen, juriya, kuma an gina shi don ƙarfin ƙarƙashin ƙasa na Arewacin Amurka - 750 kVA cike da tasfotoci da za ku iya amincewa da su.
01 Gabaɗaya
1.1 Fagen Aikin
An isar da shi ga Amurka a cikin 2025, wannan750kVA ruwa -cikaye guda uku{2}}kushin lokaci{3}}wanda aka ɗora wutar lantarkian ƙera shi cikin cikakkiyar yarda da IEEE Std C57.12.34{1}}2022, yana mai da shi da kyau{2}} ya dace da tsarin rarraba wutar lantarki a faɗin Arewacin Amurka.
Wannan ruwa mai nauyin kVA 750 -cike da taswira yana da madauki{2}} tsarin ciyarwa don sassauƙan haɗin cibiyar sadarwa da ingantaccen ƙarfin wuta. Matattu{4}} ƙira na gaba yana tabbatar da aiki mai aminci a cikin jama'a ko babba{5}} wuraren shiga ta hanyar kawar da abubuwan da aka fallasa. Mai kamun gwiwar hannu don kariyar wuce gona da iri. Ƙafafunsa guda biyar - yana ɗaukar daidaitaccen sifili{9}} jeri-juyayi ƙarƙashin yanayin nauyi mara nauyi, yana haɓaka aiki a ainihin cibiyoyin rarraba duniya.
Ruwan ester na halitta na FR3 azaman matsakaicin insulating. FR3 wuta ce -lafiya, mai yuwuwa, kuma mai dacewa da muhalli madadin mai ma'adinai, yana ba da babban ma'ana mai walƙiya da kyakkyawan aikin zafi.
Yana da kyau ga unguwannin bayan gari, wuraren shakatawa na masana'antu, wuraren kasuwanci, da cibiyoyin karatun da ke buƙatar ingantaccen rarrabawar ƙasa.
1.2 Ƙayyadaddun Fasaha
750 kVA ruwa cike da ƙayyadaddun canji da takaddar bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Uku fanni kushin Dutsen transformer
|
|
Daidaitawa
IEEE Std C57.12.34-2022
|
|
Ƙarfin Ƙarfi
750 kVA
|
|
Yawanci
60HZ
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Mataki
Uku
|
|
Nau'in Sanyi
KNAN
|
|
Liquid insulant
Farashin FR3
|
|
Babban Voltage
12.47 kV
|
|
Na biyu Voltage
0.6 kV
|
|
Ƙungiyar Vector
YNyn0
|
|
Abubuwan Iska
Copper
|
|
Adadin ainihin kafa
5
|
|
Impedance
5.75%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
0.99 kW
|
|
Akan Rasa Load
5.6 kW
|
|
Na'urorin haɗi
Mai kame gwiwar hannu
|
1.3 Zane
750 kVA ruwa cike da ma'aunin wutar lantarki da cikakkun bayanai masu nauyi
![]() |
![]() |
02 Masana'antu
2.1 Kori
750kVA, 12.47/0.6kV YNyn0 pad{4}}saka ruwa-wayoyin wutan lantarki da aka nutse suna ɗaukar ƙirar ƙirar ƙafa biyar{6} don tabbatar da ingantaccen sarrafa sifili{7} jeri wanda ya haifar ta rashin daidaituwa lodi ko tsarin ƙasa. Ƙarin gaɓoɓin gefe suna ba da ƙananan hanyar ƙin yarda don juzu'in jeri na sifili, yana tabbatar da ingantaccen aikin rufewa, ƙaramar ƙara, da ingantacciyar aminci a ƙarƙashin ainihin yanayin rarrabawar duniya.

2.2 Guda

An kammala coils na YNyn0 vector group transformer ta amfani da madugu na jan karfe{1}}warkar da iska don gefen LV da jujjuyawar waya na gefen HV. A yanzu ma'aikata suna cire gyare-gyaren da aka yi amfani da su bayan sun tabbatar da cewa coils sun cika girma da buƙatun rufi. Ana ci gaba da shirye-shirye don mataki na gaba: core da coil taro, inda za a ɗora iska a kan tsarin tushen ƙarfe.
2.3 Tanko
Tankin da aka rufe tare da murfi, wanda aka yi da ƙarfe mai laushi, ya kammala aikin zanen sa kuma yana jiran ingantacciyar dubawa. Masu dubawa za su duba kaurin fim ɗin fenti, santsin saman ƙasa, da bayyanar gaba ɗaya. Idan an sami lahani irin su blisters, bawo, ramuka, tabo mara kyau, mayafi mara kyau, ko tarkace, za a sanar da mai kula da zanen kuma a ba da odar sake yin aiki. Mataki na gaba shine taron tanki, gami da babban tanki, ƙofar gidan hukuma, gindin skid, da shinge, da sauransu.

2.4 Taron Karshe

An kammala taron ɓangaren aiki na 750kVA 12.47/0.6kV guda uku{3}}kushin lokaci{4}wanda aka ɗora tasfoma, gami da core stacking, shigar da iska, haɗin gubar, da shigar da NLTC (babu-mai sauya matsa lamba). Wani mai fasaha a halin yanzu yana gudanar da gwajin juriya tsakanin iska da ƙasa ta amfani da megohmmeter na dijital don tabbatar da yanayin rufewa kafin motsawa zuwa matakin samarwa na gaba.
03 Gwaji


Gwajin Na yau da kullun da Matsayin Gwaji
1. Ma'aunin Juriya na Insulation: Dangane da IEEE C57.12.90-2021
Manufar
Kula da kayan rufewa da tsarin masana'anta kuma duba bushewa da tsabtar jiki.
2. Gwajin Rabo: Dangane da IEEE C57.12.90-2021 Sashe na 7 & Sashe na 9.1
Manufar
a) Bincika ko an haɗa gubar famfo daidai, kuma ƙimar wutar lantarki na kowane iska daidai kuma ya cika buƙatun.
b) Ko ƙungiyar haɗin gwiwa ta cika ka'idodin yarjejeniyar.
3. Mataki na -Gwajin dangantaka: Dangane da IEEE C57.12.90-2021 Sashe na 6
Manufar
a) Ko Polarity da dangantakar lokaci sun cika buƙatun yarjejeniyar.
b) Kowane lokaci na wani polyphase transformer zai kasance yana da polarity na dangi iri ɗaya
4. Ma'aunin Juriya: Dangane da IEEE C57.12.90-2021 Sashe na 5
Manufar
a) Lissafin ɓangaren I²R na asarar madugu
b) Lissafin yanayin zafi a ƙarshen gwajin tashin zafin jiki{0}
c) A matsayin gwajin kula da inganci na tsarin masana'antu
d) A matsayin tushe don tantance yiwuwar lalacewa a cikin filin
5. Babu Asara Load kuma Babu Load Yanzu: Dangane da IEEE C57.12.90-2021 Sashe na 8 & Sashe na 9.3
Manufar
a) Auna babu{0}}asara a ƙayyadadden ƙarfin ƙarfin kuzari da ƙayyadadden mitar.
b) Auna babu{0}}load na halin yanzu kuma babu- asarar kaya ko ya dace da ka'idoji da ka'idojin fasaha.
6. Load Load, Impedance Voltage da Inganci: Dangane da IEEE C57.12.90-2021 Sashe na 9 & 9.2
Manufar
Bincika idan ƙarfin lantarki na impedance da ƙimar asarar kaya daidai da ƙa'idodi da ƙa'idodin fasaha.
7. Gwajin Wutar Lantarki da Aka Aiwatar: Bisa ga IEEE C57.12.90-2021 Sashe na 10.6
Manufar
Bincika ƙarfin jurewar babban rufin na'urar wuta.
8. Gwajin Jurewar Wutar Lantarki: Dangane da IEEE C57.12.90-2021 Sashe na 10.7
Manufar
Bincika ƙarfin rufewa na tsaye na taransfoma.
9. Gwajin Leak tare da Matsi don Masu Canjin Ruwa na Ruwa: A cewar IEC60076-1
Za a gudanar da gwajin yabo a 20KPa na awanni 24 ba tare da yabo ba. Babu nakasar dindindin.
Manufar
Don tabbatar da tankin transfoma ba zai zube cikin sabis ba.
04 Shiryawa da jigilar kaya
![]() |
![]() |
05 Yanar Gizo da Takaitawa

Daga ainihin gini zuwa taro na ƙarshe, tsarin masana'anta yana jaddada amincin tsari, aikin lantarki, da dorewar lokaci mai tsawo{{0}. An ɗauki ƙirar ainihin ƙafar ƙafa biyar{2} don haɓaka aiki a ƙarƙashin yanayin nauyi mara nauyi, yayin da iskar jan ƙarfe yana tabbatar da ingantaccen ƙarfin lantarki da kwanciyar hankali. Tankin da aka rufe da fenti yana fuskantar ƙaƙƙarfan bincike mai inganci kafin haɗawa cikin taron kewaye.
Kowane matakin samarwa - core stacking, coil winding, tanki ƙirƙira, da kuma insulation gwajin - ana aiwatar da shi sosai don tabbatar da biyan buƙatun ƙira da tsammanin aikin filin. Sakamakon yana da ƙarfi, mai amfani{3}} na'urar taswira da aka gina don amintaccen sabis a cikin wuraren rarrabawa.
Hot Tags: ruwa cike da wutar lantarki, masana'anta, mai kaya, farashi, farashi
You Might Also Like
500 kVA Kushin Haɓaka Mai Canjin wurin zama-34.5 / 0...
750 kVA Kushin Haɓaka Kudin Canji-13.8 / 0.22 kV|Guy...
75 kVA Pad Dutsen-23 / 0.208 kV|Amurka 2025
750 kVA Kushin Dutsen Mai Canjawa-25 / 0.6 kV|Kanada...
5 MVA Pad Dutsen Masu Canzawa-33 / 0.48 kV|Amurka 2025
300 kVA Mai Cika Mai Sauƙi-13.2 / 0.48 kV|Guyana 2024
Aika Aikace-aikacen