1000 KVA Kushin Haɓaka Mai Haɓakawa Manufacturer-12.47 / 0.48 KV|Amurka 2025

1000 KVA Kushin Haɓaka Mai Haɓakawa Manufacturer-12.47 / 0.48 KV|Amurka 2025

Ƙasar Bayarwa: Amurka 2025
Yawan aiki: 1000kVA
Wutar lantarki: 12.47/0.48 KV
Feature: DOE ingantaccen makamashi
Aika Aikace-aikacen

Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'antun da masu samar da 1000 kva pad mounted transformer-12.47/0.48 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

 

1000 kVA pad mounted transformer

Amintaccen kushin da aka ɗora wutar lantarki don grid na Arewacin Amurka, haɗa amincin FR3, ingantaccen aiki, da cikakken bin IEEE/DOE.

 

 

01 Gabaɗaya

1.1 Fassarar Ayyukan da Aikace-aikace

An isar da shi zuwa Amurka a cikin 2025, wannan 1000kVA uku na kushin da aka saka taransifoma an shigar da shi a cikin madauki na karkashin kasa{2}} tsarin rarraba ciyarwa inda ake sa ran ci gaba da aiki, saurin sauyawa, da kwanciyar hankali na tsawon lokaci{3} a yanayin filin gaske, ba kawai akan takarda ba.

A cikin irin wannan nau'in hanyar sadarwa, ba a ɗaukar kushin da aka ɗora taswira a matsayin naúrar juyawa mai sauƙi; yana yin kama da kafaffen kumburin lantarki a cikin grid ɗin rarrabawa, inda canjin kaya, kurakurai, da jujjuyawar wutar lantarki duk ke wucewa kuma dole ne a sarrafa shi da kyau.

An ƙididdige shi a 12.47kV zuwa 0.48kV, na'urar da aka ɗora taswirar ta yi daidai da daidaitaccen matsakaicin matsakaici na Arewacin Amurka{2}}zuwa{3}}tsarin ƙarancin wutar lantarki, yawanci ana amfani da shi a cikin kasuwanci, masana'antu haske, da aikace-aikacen kayan more rayuwa tare da gauraye da bayanan martaba masu ƙarfi.

 

1.2 Kanfigareshan Wutar Lantarki da Ƙungiyar Vector (YNd1)

Wannan1000kVA kushin saka transformeryana amfani da 12.47kV tushen wye firamare da 0.48kV delta secondary, YNd1 vector group, wanda aka zaɓa don kula da halayen ƙasa, kwararar jituwa, da rashin daidaituwar kaya a cikin tsarin rarraba aiki.

Gefen wye na ƙasa yana haɓaka kwanciyar hankali na tsarin tsarin da gano kuskure, yayin da iskar delta ke taimakawa rage jituwa sau uku da iyakance yaɗuwar tashin hankali, musamman lokacin da kushin da aka ɗora taswira yana ba da kaya mara nauyi kamar VFDs, tsarin UPS, ko tashoshin caji na EV.

 

1.3 Tsare-tsare (5.75%)

Tare da 5.75% impedance, wannan kushin da aka ɗora tafsiri yana daidaita ma'auni na gajeriyar ƙayyadaddun kewayawa na yanzu, ƙa'idar wutar lantarki, da daidaitawar kariya.

Yana taimakawa sarrafa matakan kuskure, yana goyan bayan daidaitawar mai karyawa, kuma yana kula da ingantaccen ƙarfin lantarki yayin bambancin kaya, tabbatar da ingantaccen aiki a ƙarƙashin yanayin al'ada da na wucin gadi.

 

 

1.4 Ƙayyadaddun Fasaha

1000kVA uku lokaci kushin saka gidan wuta ƙayyadaddun bayanai da takardar bayanai

Isarwa zuwa
Amurka
Shekara
2025
Nau'in
Uku fanni kushin Dutsen transformer
Daidaitawa
IEEE Std C57.12.34-2022
Ƙarfin Ƙarfi
1000 KVA
Yawanci
60HZ
Ciyarwa
Madauki
Gaba
Matattu
Mataki
uku
Nau'in Sanyi
KNAN
Liquid insulant
Farashin FR3
Babban Voltage
12.47GrdY/7200
Na biyu Voltage
0.48D
Ƙungiyar Vector
YNd1
Abubuwan Iska
Aluminum
Impedance
5.75%
inganci
DOE
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
1.3 kW
Akan Rasa Load
6.94 kW
Na'urorin haɗi
Tare da mai kamewa

 

1.5 Zane

1000kVA uku lokaci kushin saka transformer zane da sunan farantin

1000 kva pad mounted transformer-technical-drawing 1000 kva pad mounted transformer-nameplate

 

 

02. Tsarin Tsara, Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwaƙwalwa na Ƙaƙwalwa

2.1 Tsarin Tsarin Rarraba

1000 kva pad mounted transformer-front-door-close

Wannan 1000kVA uku na kushin kushin da aka ɗora tasfoma yana ɗaukar madaidaicin abinci da mataccen tsarin gaba, yana ba da damar aiki mai aminci da ci gaba da sauyawar wutar lantarki a cikin tsarin rarraba ƙasa na Arewacin Amurka.

A cikin ayyukan da aka saba amfani da su da na kasuwanci, ana amfani da wannan saitin na'ura mai ɗaukuwa da taswira inda ake buƙatar kwanciyar hankali na tsawon lokaci da aiki mai aminci.

 

2.2 Ayyukan Insulation (FR3 Oil)

Wannan kushin da aka ɗora na'urar wuta yana amfani da ruwa mai ester na halitta na FR3, yana haɓaka aikin amincin wuta, yarda da muhalli, da kwanciyar hankali na dogon lokaci-.

A lokacin masana'antu, bushewar injin, cika mai, da tsarin rufewa ana sarrafa su sosai don tabbatar da ingantaccen aikin injin na'urar da aka ɗora a ƙarƙashin yanayin aiki na gaske.

1000 kva pad mounted transformer-activepart

 

2.3 Yarda da Kariya

1000 kva pad mounted transformer-High Level bushing
1000 kva pad mounted transformer-low Level bushing
1000 kva pad mounted transformer Standard Monitoring & Protection Accessories

Taswirar da aka ɗora kushin ya dace da buƙatun dacewa na DOE da ka'idodin IEEE C57.12.34, yana tabbatar da dacewa tare da grid na Arewacin Amurka da karɓar kayan aiki.

UL/cUL goyon bayan bin doka da haɗin kai masu kamawa galibi ana haɗa su don haɓaka amincin aiki da aikin kariya.

 

 

03 Halayen Masana'antu

3.1 Core da Winding

1000 kva pad mounted transformer-silicon-steel-core
1000-kva-pad-mounted-transformer-winding-process-coil-winding-worker-operation

Ana amfani da ƙarfe na siliki mai girma - don ainihin don rage asara, yayin da iskar aluminium ke ba da ma'auni tsakanin ingancin farashi da aikin zafi.

Kowane kushin da aka ɗora tafsiri an ƙera shi tare da sarrafawar masana'antu don tabbatar da ingantaccen aiki a ƙarƙashin ci gaba da ɗaukar nauyi da gajeriyar yanayi{0}.

 

3.2 Tsarin Tanki

1000 kva pad mounted transformer-oil-tank

Tankin da aka rufe tare da murfin foda RAL 9003 yana tabbatar da juriyar lalata da tsayin lokaci mai tsawo a waje.

Ana amfani da tsauraran matakan rufewa da matakan jiyya don tabbatar da amincin kushin da aka ɗora tasfo a cikin yanayi mai tsauri.

 

04 Shiryawa da sufuri

1000 kva pad mounted transformer-vacuum-packaging-in- aluminum-foil-bag
1000 kva pad mounted transformer-wooden-crate-packaging

 

05 Yanar Gizo da Takaitawa

Wannan 1000kVA uku na kushin da aka ɗora kayan wuta an tsara shi don ingantaccen aiki a cikin tsarin rarrabawar Arewacin Amurka, haɗa aminci, inganci, da aikin muhalli.

Daga ƙira zuwa masana'anta, an fi mayar da hankali kan tabbatar da kowane na'ura mai ɗaukar hoto zai iya aiki da ƙarfi a cikin mahallin grid na gaske tare da yarda da dorewa na tsawon lokaci.

 

Hot Tags: kushin mounted transformer manufacturer, masana'anta, maroki, farashin, tsada

Aika Aikace-aikacen