150 kVA Liquid Cika Mai Canjawa-13.2 / 0.48 kV|Kanada 2024

150 kVA Liquid Cika Mai Canjawa-13.2 / 0.48 kV|Kanada 2024

Kasar: Kanada 2024
Yawan aiki: 150kVA
Wutar lantarki: 13.2/0.48kV
Feature: tare da OCTC
Aika Aikace-aikacen

 

 

liquid filled transformer

Ba tare da ƙoƙartawa ba tare da haɗaɗɗun buƙatun wutar lantarki - Uku{0}}Pad Pad{1}Mounted Transformer yana tabbatar da kowane kilowatt abin dogaro da inganci!

 

01 Gabaɗaya

1.1 Fagen Aikin

Kwanan nan SCOTECH ya fitar da wani saman -na{1}}{2}}layi 150kVA da aka ɗora tasfofi zuwa Kanada. Babban ƙarfin wutar lantarki na na'urar shine 13.2Y/7.62kV, yayin da ƙarfin lantarki na biyu shine 0.48Y/0.277kV tare da ƙarfin lantarki guda biyu a gefen LV, wanda shine ainihin bambancin wannan transfomer.

The pad mounted transformer, shi ne cikakken sa na lantarki kayan aiki da cewa hada da transformer, da loading da kuma na'urar kariya fiusi na babban ƙarfin lantarki halin yanzu part, da load switch da na'urar kariyar fiusi na low irin ƙarfin lantarki halin yanzu part, da ma'auni da sauyawa na low irin ƙarfin lantarki rarraba part. Ana sanya jikin na'urar transfoma, babban maɓalli{1} ƙarfin wuta, fuse da sauran abubuwan haɗin gwiwa tare a cikin tankin na'urar, saboda nutsewa cikin mai, ƙarar kayan aikin yana raguwa sosai, tsarin yana da ɗanɗano, mai sauƙin shigarwa da sassauƙa. Cikakken tsari, cikakken tsari, mai aminci kuma abin dogaro, mai sauƙin aiki, kulawa{3}} kyauta. Ana amfani da shi sosai a wuraren zama, manyan cibiyoyin masana'antu, masana'antu da masana'antar hakar ma'adinai, filayen jirgin sama, tashoshi, makarantu da sauran wurare.

Babban ɓangaren wutar lantarki yana ɗaukar cikakken mashigin wutar lantarki mai ƙarfi da tashoshi da na'urorin haɗi na kebul, ta yadda babu wani ɓangaren da aka fallasa a cikin babban tazarar wutar lantarki, tare da amintattun halayen aiki; Kariyar fuse mai matsa lamba biyu, filogi{0}a cikin fuse yana da sifofin zafin jiki da kariya mai mahimmanci sau biyu na yanzu, fis ɗin ajiya don kare kuskuren taransfo; A lokaci guda kuma, yana da cikakken kewayon kayan aikin dubawa, kamar ma'aunin matsa lamba, bawul ɗin matsa lamba, ma'aunin matakin mai, ma'aunin zafin mai, da sauransu.

Ƙananan ɓangaren wutar lantarki an sanye shi da madaidaicin ma'auni don auna ƙarfin lantarki, halin yanzu, ƙarfin aiki, ƙarfin amsawa, zazzabi da sauran sigogi a ƙayyadaddun wuri. Shigar da na'urar karanta mitar mai amfani ta atomatik, na iya kwafin wutar lantarki ta atomatik na duk ƙananan masu amfani da wutar lantarki na wannan taransifoma ta hanyar mai ɗauka ko yanayin waya; Ƙarƙashin rarraba wutar lantarki yana sanye take da aikin kariyar asarar lokaci, wanda zai iya gano asarar lokaci kuma yana ƙarfafa kowane mai amfani don hana cutar da rashin aiki na lokaci mai cikakken--; Ƙananan ma'auni yana sanye da fan, wanda ta atomatik jefa da kuma fitar da zafi bisa ga yawan zafin jiki, farawa a digiri 45 kuma ya dawo a digiri 40.

 

1.2 Ƙayyadaddun Fasaha

150 KVA kushin da aka ɗora ƙayyadaddun taswira da takaddar bayanai

Isarwa zuwa
Kanada
Shekara
2024
Samfura
150KVA-13.2Y(7.62)/0.48Y(0.277)KV
Nau'in
Tashin wutar lantarki
Daidaitawa
IEEE C57.12.34
Ƙarfin Ƙarfi
150 KVA
Yawanci
60HZ
Mataki
3
Nau'in Sanyi
ONAN
Babban Voltage
13.2Y (7.62) KV
Na biyu Voltage
0.48Y (0.277) KV
Abubuwan Iska
Aluminum
Matsala ta kusurwa
YNyn0
Polarity
Ƙara
Impedance
5±7.5%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
0.29KW
Akan Rasa Load
1.52KW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

150 KVA kushin da aka ɗora zane da girman hoto.

liquid filled transformer diagram liquid filled transformer nameplate

 

 

02 Masana'antu

2.1 Kori

Babban kayan an yi shi da babban -sanyi mai inganci{1}} hatsin da aka yi birgima{2}} silicon karfe takardar. Silicon karfe da kansa wani abu ne na maganadisu tare da karfin maganadisu mai ƙarfi. A cikin coil mai kuzari, zai iya samar da babban ƙarfin shigar da maganadisu, wanda zai iya rage ƙarar na'urar. Mun san cewa ainihin mai canzawa koyaushe yana cikin jihar AC, kuma asarar wutar lantarki ba wai kawai a cikin juriya na nada ba ne, har ma a cikin madaidaicin maganadisu na yanzu. Yawanci hasarar wutar lantarki a cikin core iron ana kiranta da baƙin ƙarfe, hasarar baƙin ƙarfe na faruwa ne ta dalilai guda biyu, ɗaya shine asarar maganadisu, ɗaya shine hasara na yanzu. Asarar Magnetic ita ce asarar baƙin ƙarfe ta hanyar abubuwan maganadisu a cikin aikin magnetization na ainihin, kuma girman wannan asarar ya yi daidai da girman yankin da ke kewaye da madauki na kayan abu. Magnetic madauki na silicon karfe kunkuntar, kuma Magnetic asarar core na transformer da shi kadan ne, wanda zai iya ƙwarai rage dumama digiri.

liquid filled transformer core

 

2.2 Guda

liquid filled transformer winding

Ƙarƙashin ƙarfin lantarki mai jujjuyawa

● Rarraba halin yanzu axial yana daidaitawa da yardar kaina

● Yana rage karfin sassa

● Bayan iska, Prepreg yana makale a kan takardar jagora don samar da ƙaramin bututu ta hanyar yanayin zafi.

Babban ƙarfin wutar lantarki

● Cikakkun na'urori masu jujjuyawa na atomatik{{0}

● Enamel{0}}wayar da aka keɓe tare da tsayayye mai jujjuyawa a kan silinda mai ɗaukar kaya, ko kai tsaye a kan iskar LV

● Ƙimar takarda mai inganci mai inganci{{0}

● Rufe bandeji da aka yi da foil mai raguwa don ƙaƙƙarfan iska mai kyau tare da ingantaccen amsawar kewayawa da ingantaccen rarraba wutar lantarki mai ƙarfi.

 

2.3 Tanko

Kamfaninmu yana amfani da ƙaramin ƙarfe mai inganci{0}a matsayin ɗanyen kayan aikin samar da tankunan mai, kuma yana amfani da injina na ruwa ko wasu kayan aiki don lanƙwasa, yanke da danna farantin karfen zuwa siffar da ake so na tankin mai. Butt da aka gyara da kuma yi gas garkuwa waldi ko wasu waldi matakai don tabbatar da tightness da tsarin ƙarfi na tanki. An rufe dukkan hatimi a ƙarshen iyaka; An zagaye sassan ƙarfe a ciki da wajen akwatin don cire gashi, kuma ana gwada suturar weld da hatimi har sau uku (hasken haske, matsi mai kyau, gwajin yabo mara kyau); Ana yin fenti bisa ga daidaitattun buƙatun hana tsatsa-.

liquid filled transformer tank

 

2.4 Taron Karshe

liquid filled transformer final assembly

Tsarin akwatin Amurka - nau'in na'ura mai haɗawa ya kasu kashi biyu, gaba shine ma'aunin wutar lantarki, ma'aunin wutar lantarki ya haɗa da tashoshi masu tsayi da ƙananan wuta, babban ƙarfin wutar lantarki, toshe {{1} a cikin fiusi, babban matsi mai canjin mai aiki, mitar ɗanɗanon mai, mitar zafin mai, da sauransu; A baya akwai akwatin mai da mazubin zafi, iska mai isassun wuta, ƙarfen ƙarfe, babban ƙarfin wutar lantarki, filogi{3} a cikin fuse suna cikin jikin tanki. Load switches, fuses, da transformers ana nutsar dasu cikin mai.

Shigar da tasha a kan mahalli, sanya baƙin ƙarfe da aka haɗa a cikin tankin mai, gyara screws bayan an shigar da baƙin ƙarfe, sa'annan a saka fis mai ƙarfi. Bayan an kammala duk matakan da ke sama, cika tankin mai.

 

 

03 Gwaji

Kushin da aka ɗora gwajin wutar lantarki an raba shi zuwa hanyoyin haɗin yanar gizo masu zuwa: dubawar bayyanar, gwajin aikin lantarki, gwajin juriya na iska, gwajin asarar kaya, gwajin hawan zafi da gwajin aiki.

1. Duban bayyanar: Ana gudanar da binciken bayyanar akwatin Amurka don bincika ko akwatin, iska, kayan rufewa, da dai sauransu, ba su da kyau.

2. Gwajin aikin lantarki: Yi amfani da kayan gwajin lantarki don gwadawa da duba aikin wutar lantarki na injinan akwatin Amurka, gami da wayoyi, juriya na juriya, juriya na jujjuyawar iska, gwajin ƙarfin lantarki, casing current da sauran cak.

3. Gwajin juriya na iska: Yi amfani da kayan gwaji don gwadawa da kuma duba juriyar juriya na akwatin Amurka.

4. Gwajin hasarar lodi: Zana ɗan ƙaramin adadin na yanzu bisa ga ƙimar da aka ƙididdige na'urar taswirar akwatin Amurka don bincika ko asarar da ingancin injin na'urar ta dace da buƙatun ƙira.

5. Gwajin hawan zafin jiki: daidaita ƙarfin shigarwar shigarwa da nauyin akwatin Amurka, lura da yanayin gudu na akwatin, gwada hawan zafin jiki, hawan zafin jiki, zafin mai, da dai sauransu.

6. Gwajin aiki: injin akwatin akwatin Amurka na dogon lokaci yana gudana gwajin, koyaushe daidaita ƙarfin shigarwa, girman kaya, da dai sauransu, don bincika aiki da kwanciyar hankali na injin akwatin.

 

liquid filled transformer test
liquid filled transformer routine test

 

 

04 Shiryawa da jigilar kaya

liquid filled transformer packaging liquid filled transformer loading

05 Yanar Gizo da Takaitawa

Na gode don sha'awar ku ga kushin mu guda uku - wanda aka ɗora{1} Tare da ingantaccen aiki mai inganci kuma abin dogaro, ƙaƙƙarfan ƙira mai ƙayatarwa, da keɓaɓɓen fasalulluka na aminci, wannan samfurin ya zama kyakkyawan zaɓi don tsarin rarraba wutar lantarki na masana'antu, kasuwanci, da jama'a. Mun himmatu wajen samar da cikakkun hanyoyin samar da wutar lantarki da ayyuka masu ƙima don biyan buƙatun kasuwa. Komai bukatun aikin ku, muna nan don tallafawa nasarar ku tare da ƙwarewa da sadaukarwa. Muna sa ran kafa haɗin gwiwa na dogon lokaci tare da ku da haɓaka inganci da dorewa a cikin masana'antar wutar lantarki tare! Don ƙarin bayani, da fatan za a iya tuntuɓar mu kowane lokaci!

transformer project

 

Hot Tags: ruwa cike da wutar lantarki, masana'anta, mai kaya, farashi, farashi

Aika Aikace-aikacen