1000 kVA Kushin Haɗa Mai Canjawa-13.2 / 0.48 kV|Amurka 2025

1000 kVA Kushin Haɗa Mai Canjawa-13.2 / 0.48 kV|Amurka 2025

Kasar: Amurka 2025
Yawan aiki: 1000 kVA
Wutar lantarki: 13.2/0.48kV
Feature: tare da IFD
Aika Aikace-aikacen

 

 

1000 kva pad mounted transformer

Ƙirƙirar fasaha, cikakkiyar dacewa - na uku{1}} na'ura mai ɗaukar wutan lantarki yana haifar da sabuwar gaba ga masana'antar wutar lantarki!

 

01 Gabaɗaya

1.1 Fagen Aikin

1000 kVA uku fanti pad mounted transformer aka kawo wa Amurka a 2025. Ƙimar ikon na'urar shine 1000 kVA tare da ONAN sanyaya. Babban ƙarfin lantarki shine 13.2GrdY / 7.62 kV tare da kewayon tapping ± 2 * 2.5% (NLTC), ƙarfin lantarki na biyu shine 0.48Y / 0.277 kV, sun kafa ƙungiyar vector na YNyn0.

An ƙera tafkunan mu{0}waɗanda aka ɗora su don su kasance masu juriya ga ɓata lokaci da yanayi, suna sanya su lafiya don sanyawa a wuraren jama'a. Kowane shinge an gina shi da ƙarfe mai nauyi{2}}ƙarfe kuma foda ne - an rufa shi da gasa mai ɗorewa{4}} akan gamawa don haɓaka juriya. Muna ba da na'urorin gaba da matattu- na gaba na pad ɗin mu{8}}waɗanda aka ɗora su, waɗanda suka zo tare da daidaitawar radial ko madauki. Na'urorin da aka ɗora kumfa na zamani yawanci suna ɗaukar ingantacciyar ƙira don rage yawan amfani da makamashi da farashin aiki, yayin da ruwan wutan lantarki da ake amfani da shi galibi kayan aikin muhalli ne. Ana aiwatar da matakan kariya daban-daban, kamar kariya ta wuce gona da iri, gajeriyar kariyar kewayawa, da sa ido kan kuskuren ƙasa, don tabbatar da amintaccen aiki a ƙarƙashin yanayin aiki daban-daban. Ana amfani da tasfotoci masu ɗorewa a wuraren zama, yankunan kasuwanci, wuraren shakatawa na masana'antu, da tsarin rarraba wutar lantarki na karkara, suna biyan buƙatu daban-daban.

 

 

1.2 Ƙayyadaddun Fasaha

1000kVA uku lokaci kushin saka gidan wuta ƙayyadaddun bayanai da takardar bayanai

Isarwa zuwa
Amurka
Shekara
2025
Nau'in
Face kushin hawa uku na wuta
Daidaitawa
IEEE C57.12.00
Ƙarfin Ƙarfi
1000kVA
Yawanci
60HZ
Mataki
Single
Nau'in Sanyi
ONAN
Babban Voltage
13.2GrdY/7.62kV
Na biyu Voltage
0.48Y/0.277 kV
Abubuwan Iska
Aluminum
Impedance
5.75%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
1.3KW
Akan Rasa Load
6.94KW
Na'urorin haɗi
Daidaitaccen Kanfigareshan
Jawabi
N/A

 

1.3 Zane

1000 kVA uku lokaci kushin da aka ɗora ma'auni mai girma da cikakkun bayanai masu nauyi

three phase transformer wiring diagram wiring diagram for 3 phase transformer

 

 

02 Masana'antu

2.1 Kori

Rukuni guda uku{0}sashi na uku{1} sun ƙunshi ginshiƙai guda uku da aka jera a tsaye, kowanne yayi daidai da wani lokaci na wutar lantarki. Wadannan ginshiƙan an haɗa su ta hanyar ƙwanƙwasa a kwance, suna samar da tsari mai tsauri wanda ke ba da ƙarfin injiniya mai kyau da kwanciyar hankali. Wannan ƙira yana tabbatar da cewa mai canzawa zai iya jure matsalolin injina daban-daban yayin aiki yayin da yake riƙe mafi kyawun aikin maganadisu. Rukunin rukunin guda uku-sashi na uku{6}} yana samar da rufaffiyar da'irar maganadisu, yadda ya kamata tana mai da hankali kan jujjuyawar maganadisu da rage zubewar maganadisu. Ana yin ainihin da ƙananan zanen ƙarfe na silicon - ƙananan waɗanda aka jera su tare. Waɗannan zanen gadon ƙarfe na silicon suna da ingantattun kaddarorin lantarki waɗanda ke rage asara na yau da kullun da asarar hysteresis.

shell type transformer

 

2.2 Guda

20251201104931822177

Ƙarƙashin mai riƙe da wutar lantarki don kumfa{1}}aramin wutar lantarkin da aka ɗora{1}tasfoma shine mahimmin ɓangaren tsarin da aka ƙera don tabbatarwa da daidaita bushings a cikin jeri sama da buɗewa goma. Ta hanyar samar da ingantacciyar goyan bayan injina, yana tabbatar da daidaitawa da amincin kayan aikin bushewa da yawa, yadda ya kamata yana rage haɗarin lalacewa daga girgizawa, hawan keken zafi, ko ƙarfin waje, ta haka yana haɓaka aminci na dogon lokaci da amincin na'urar ta atomatik.

 

2.3 Tanko

Ya kamata tankin mai na transfoma ya samar da kayan aikin girka kayan aikin, kamar yadda aka nuna a shafi na 2. A lokaci guda kuma, ya kamata a samar da wurin shigar da magudanar ruwa mai inci 1{2} daga ciki na ƙananan rukunin wutar lantarki{6} zuwa wurin da mitar wutar lantarki take. Dole ne a sami damar buɗe dukkan kofofin ba tare da wani cikas ba (kamar na'urar lantarki, da sauransu). Lokacin da ƙayyadaddun ƙayyadaddun ƙayyadaddun rukunin ƙananan ƙarfin lantarki yana ba da mafi ƙarancin girman inci 16 1/2 inci x 33 1/4 inci na sarari kuma a tsayin da aka kayyade a shafi na 2, ba a buƙatar wurin shigar kayan aiki.

oil tank prices

 

2.4 IFD

IFD

Gano Laifin Insulation (IFD) don masu canzawa tsarin sa ido kan layi ne wanda ke aiki azaman na'urar faɗakarwa ta hanyar ci gaba da sa ido kan iskar hydrogen gas (H₂) da ke narkewa a cikin mai. Yana gano matakan farko na kurakuran rufewa na ciki, kamar fitar da wani sashi ko zafi mai zafi, wanda ke haifar da hydrogen, yana ba da izinin kiyayewa gabaɗaya kafin waɗannan batutuwa su ƙaru zuwa manyan gazawa. Mahimmanci, IFD tana aiki azaman gwajin lafiyar lafiya don masu canji, haɓaka aminci da hana lalacewar bala'i ta hanyar gano kurakuran ɓoye a matakin farko kuma mafi sauƙin sarrafawa.

 

 

 

03 Gwaji

3. Duban Ayyukan Buɗe Kofa da Rufewa
Wannan abin da ake buƙata ya ƙunsa cewa kafin masana'antar taransifoma ta kawo kayan aiki, yakamata a gudanar da ayyukan buɗe kofa da rufewa da yawa don bincika ko ƙofar tana aiki yadda ya kamata, guje wa al'amurra kamar rashin daidaituwa, nakasawa, ko shigarwa mara kyau.
• Abubuwan Gwaji: Yawancin gwaje-gwajen aikin injiniya, gami da mitar buɗe kofa da rufewa, santsi, da aikin rufewa.
• Daidaitaccen Bukatun: Wannan gwajin yana tabbatar da cewa shingen tafsiri ko canza panel bai lalace ta jiki yayin amfani ba, kuma buɗewar kofa da ayyukan rufewa suna kula da kyakkyawan yanayin aiki.
• Ka'idodin ANSI: Ko da yake wannan abu na iya zama ba a jera shi a sarari a cikin duk ma'auni na ANSI ba, ana samun irin wannan buƙatun a cikin ƙayyadaddun bayanai kamar ANSI C57.12.90 (Buƙatun Gwajin Gwaji don Masu Transformers), yana tabbatar da amincin duk kayan aikin waje.

 

short circuit test on transformer is conducted to determine
sumpner test of transformer

 

 

04 wasu

4.1 bukata

Pad -wayoyin da aka ɗora da su za su haɗa da tankin na'ura mai canzawa da ƙananan igiyoyi masu ƙarfi da ƙananan wuta. Za a haɗa tankin tasfoma da ɗakunan ajiya azaman naúrar don shigarwa akan kushin. Babu fallasa sukukuwa, kusoshi ko wasu na'urori masu ɗaure masu cirewa na waje akan waje. Kada a sami buɗe ido da abubuwa na waje kamar rassa, sandunan ƙarfe ko wayoyi za su iya haɗuwa da sassa masu rai. Za a samar da hanyoyin da suka dace don kulle kofofin ɗakin. Hakanan za'a samar da 1/2-inch hex head bolt tare da ajin zaren NC 2 kuma daban da na'urar kullewa kamar yadda aka nuna a cikin abin da aka makala. Tsarin tsarin zai iyakance shigar ruwa (ban da ambaliya) zuwa cikin ɗakunan don guje wa yin tasiri na yau da kullun na na'urar.

20251201100552818177

 

4.2 kayan haɗi

 1000 kva pad mounted transformer transportation

The transformer za a sanye shi da shida (6) ESNA, Permali, Abubuwan da aka gyara, Cental Maloney ko Westinghouse high{1}}voltage bushing ramukan (ANSI C119.2), waje manne, domin karban kaya{3}} karya matosai don aiki da taransfoma daga babban nau'in na farko na zobe. Za a samar da kayan gyara don Elastimold Style 164BA hoisting taron zobe a wuraren da aka nuna a Haɗe-haɗe 1. Za a samar da na'urori masu ƙayyadaddun ƙayyadaddun na'urori. Za a shigar da kayan gasket yadda ya kamata don tabbatar da cewa manyan ramukan bushewar wutar lantarki{8} koyaushe suna cikin hulɗa da tankin da ke ƙasa. Tsawon maɗaukakin maɗaurin wutar lantarki zai isa ya isa don sauƙaƙa wurin maye gurbin rijiyoyin daji.

 

 

05 Yanar Gizo da Takaitawa

A ƙarshe, na'ura mai ɗawainiya na kushin lokaci uku{0} yana wakiltar ingantaccen ingantaccen mafita don buƙatun rarraba wutar lantarki na waje. Tare da ƙaƙƙarfan ƙira, fasahar rufewa na ci gaba, da ingantacciyar damar sanyaya, wannan mai canza canji yana tabbatar da ingantaccen aiki da tsawon rai, har ma a cikin ƙalubalen yanayin muhalli. Karamin sa, pad{3} da aka ɗora shi ba kawai yana adana sarari ba amma yana haɓaka aminci da sauƙin shigarwa. Ko don aikace-aikacen kasuwanci, masana'antu, ko na gundumomi, na'urorin mu na zamani guda uku{5} ɗora kushin wuta suna ba da ƙarfi da amincin da za ku iya dogaro da su. Zabi injiniyoyinmu don ɗorewa da ingantaccen makamashi mafita wanda ya dace da buƙatun yanayin yanayin makamashi na yau.