30 KVA Dry Type Transformer-11 / 0.22 KV|Hadaddiyar Daular Larabawa 2025

30 KVA Dry Type Transformer-11 / 0.22 KV|Hadaddiyar Daular Larabawa 2025

Ƙasar Bayarwa: Hadaddiyar Daular Larabawa 2025
Yawan aiki: 30kVA
Wutar lantarki: 11/0.22kV
Fasalin: Yakin IP20
Aika Aikace-aikacen

Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin masana'antun da suka fi dacewa kuma masu samar da 30 KVA Dry Type Transformer -11/0.22 KV|Hadaddiyar Daular Larabawa 2025 a China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

 

30 KVA Dry Type Transformer

Ingancin ya dace da karko tare da injin mu na busassun nau'in 30 kVA

 

01 Gabaɗaya

1.1 Bayanin Aikin

Wannan ƙaramin simintin 30 kVA -resin bushe{2}} nau'in tasfoma an ƙera shi don amintaccen matsakaici da ƙarancin wutar lantarki. Injiniyoyi don jujjuya wutar lantarki mara ƙarfi daga 11kV zuwa 0.22kV, wannan taswirar tana tallafawa har zuwa 30 kVA na kaya. Yana nuna ƙungiyar vector nau'in Yd11. An sanye wannan tafsirin da babu{10}mai sauya matsa lamba (NLTC) tare da kewayon daidaitawa na ± 2 × 2.5%. Yana ba da garantin ƙaƙƙarfan ƙa'idar wutar lantarki a ƙarƙashin sauye-sauyen kaya kwatsam, yana tabbatar da ingancin wutar lantarki mara yankewa.

Wannan busasshen na'ura mai ba da wutar lantarki{0}yana amfani da mafi inganci dayan kayan aiki. An gina ainihin asali da hatsi{3}} silikon karfe, wanda ke rage asarar ƙarfe kuma yana inganta inganci. Gishiri na jan karfe na biyu yana ba da kyakkyawan aiki. Na uku-Mataki na Class F yana ba da damar aiki a yanayin zafi har zuwa digiri 155, yana mai da shi manufa don yanayi mai zafi kamar UAE. Ingantattun kayan inganci, ƙira mafi girma da ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararru suna ba da tsayin daka{9}}.

Inganci da Asara: Wannan tafsirin ba shi da - asarar 0.12 kW da ɗora nauyi na 0.75 kW, yana rage sharar makamashi yayin da yake ci gaba da aiki. Matsakaicin kashi 4% yana iyakance gajeriyar kewayawa ({5}}waɗanda ke gudana kuma yana riƙe da ƙarfin lantarki a ƙarƙashin kaya).

 

 

 

1.2 Ƙayyadaddun Fasaha

30kVA Resin simintin busassun nau'in taswira da takaddun bayanai

Isarwa zuwa
Hadaddiyar Daular Larabawa
Shekara
2025
Nau'in
Guduro simintin busassun nau'in taswira
Babban abu
Silicon karfe takardar hatsi daidaitacce
Daidaitawa
IEC
Ƙarfin Ƙarfi
30 kVA
Yawanci
50HZ
Mataki
Single
Ƙungiyar Vector
Ii0
Nau'in Sanyi
AN
Babban Voltage
11KV
Na biyu Voltage
0.22kV
Abubuwan Iska
Copper
Impedance
4%
Matsa Canji
Farashin NLTC
Taɓa Range
± 2 * 2.5% @ ƙarfin lantarki na farko
Babu Asara Load
0.12 kW
Akan Rasa Load
0.75 kW
Matsayin rufi
F
Na'urorin haɗi
Mai sarrafa zafin jiki, Yadi

 

1.3 Zane

30kVA Resin jefa busassun nau'in mai canzawa girma da cikakkun bayanai masu nauyi

30 Kva Dry Type Transformer drawing 30 Kva Dry Type Transformer nameplate

 

02 Masana'antu

2.1 Kori

grain-oriented silicon steel core

Babban ƙira na mu guda ɗaya{0}} bushewar zamani{1}}nau'in tafofi yana amfani da zanen ƙarfe na siliki mai daidaitacce. Yana ba da kyakkyawan aiki kuma yana kiyaye naúrar ƙarami da haske. Wannan yana taimakawa inda sarari ya iyakance, kamar a cikin gidaje, ƙananan kantuna, da amfani da hasken masana'antu.

 

2.2 Guda

Busassun nau'in 30 kVA na'urorin wutan lantarki{1} suma suna amfani da ingantattun madugu na jan karfe don tabbatar da ƙarancin asara da ingantaccen ƙarfin injina. Gilashin iska suna amfani da tsarin rufin Class F (digiri 155), haɗe tare da fasahar simintin simintin haɗaɗɗen resin epoxy, yana ba da kyakkyawan juriya ga danshi, ƙura, da gajerun kewayawa, yana tabbatar da kwanciyar hankali da aminci ga abokan ciniki.

30 kVA dry-type transformer's coils

 

2.3 IP 20 Bayani

dry-type transformer IP20 enclosure

Busassun na'urar tamu ta atomatik yana amfani da shinge na IP20, wanda ke hana daskararrun abubuwa masu girma fiye da mm 12.5, kamar hulɗar ɗan adam da sassa masu rai, shiga. Yana ba da kariya daga girgiza wutar lantarki kuma yana tabbatar da aminci na asali, yana mai da shi dacewa da shigar da busassun na'ura na cikin gida{4}}

 

2.4 Taron Karshe

Abubuwan da aka ƙirƙira da abubuwan da aka ƙirƙira suna haɗuwa, yayin da ake yin haɗin wutar lantarki, rufewa, da gyare-gyaren tsari.
Ƙarƙashin injin, resin epoxy yana zubowa tsakanin iska da ainihin, yana samar da ingantaccen tsari mai warkewa.
Bayan haɗawa da warkewa, ana yin jerin gwaje-gwajen lantarki da na injina don tabbatar da cewa na'urar ta atomatik ta cika ƙa'idodin ƙira da aminci.

30 Kva Dry Type Transformer active part

 

 

03 Gwaji

Gwajin Na yau da kullun da Matsayin Gwaji

IEC 60076-1-2011 Masu Canza wutar lantarki - Kashi na 1: Gabaɗaya
IEC 60076-3-2013 Masu Canza wutar lantarki - Kashi 3: Matakan rufi, gwaje-gwajen dielectric da izinin waje a cikin iska
TS EN 60076-11-2018 RLV Masu Canza wutar lantarki - Kashi 11: Busassun na'urar wuta

1. Auna juriya na iska
2. Ma'auni na ƙarfin lantarki da kuma duba ƙaurawar lokaci
3. Ma'auni na gajere - hanawa da kuma asarar kaya
4. Ma'auni na babu asarar nauyi da halin yanzu
5. Gwajin wutar lantarki da aka yi amfani da shi
6. Gwajin jurewar wutar lantarki da aka haifar
7. Gwajin fitar da bangare

 

04 Kiɗa Da Sufuri

Resin cast dry type transformer packing Resin cast dry type transformer transportation

 

05 Yanar Gizo da Takaitawa

30 kVA Cast Resin Dry-Type Transformer

Scotech 30 kVA Cast Resin Dry{1} Nau'in Transformer yana ba da amintaccen matsakaicin matsakaici mai inganci{2}} zuwa ƙarancin wutar lantarki don gidaje, ofisoshi, shaguna, makarantu, da ƙananan masana'antu. Yana da silin karfe core da tagulla windings cikakku an rufe shi da resin epoxy, yana aiki ba tare da mai ba, kuma yana iya aiki a cikin yanayi mai zafi, ɗanɗano, ko ƙura.
Tare da A'a{0}Load Tap Changer (NLTC) don tsayayyiyar wutar lantarki da kuma shingen IP20 don aminci, yana ba da ingantaccen ƙarfi tare da ƙarancin asara da kuma rufin Class F don babban aiki na zafin jiki-.
 

Hot Tags: 30 kva busassun irin na'ura mai canzawa, masana'anta, mai kaya, farashi, farashi