630 kVA Simintin Gudun Busassun Nau'in Canji-66.6/0.55 kV|Afirka ta Kudu 2024
Yawan aiki: 630kVA
Wutar lantarki: 66.6/0.55kV
Feature: tare da fan

Resin - Fasahar simintin gyare-gyare, ingantaccen zaɓinku, yana haskaka dama mara iyaka a cikin iko!
01 Gabaɗaya
1.1 Fagen Aikin
An isar da tasfoman busasshen busasshen kVA mai nauyin 630 kVA zuwa Afirka ta Kudu a cikin 2024, ƙimar wutar lantarkin ita ce 630 kVA. Babban ƙarfin wutar lantarki na wannan busassun nau'in transfoma shine 66.6kV, ƙananan ƙarfin lantarki shine 0.55kV. Wannan babban na'urar busasshen busassun nau'in wutan lantarki an sanye shi da wani mai canza canjin kaya, kewayon tapping shine ± 2 * 2.5% a gefen farko, sanyaya shine AN/AF. Na'urar taswira tana ɗaukar tsarin sarrafa zafin sigina mai hankali, wanda zai iya ganowa ta atomatik da nuna zafin aiki na iskar lokaci guda uku, farawa da dakatar da fanka ta atomatik, kuma yana da ƙararrawa, tafiya da sauran ayyuka. An ƙera injin mu na busasshen busasshen nau'in 630 kVA tare da fasahar ci gaba kuma yana ɗaukar kayan inganci da abubuwan haɗin gwiwa, wanda ke haifar da ingantaccen inganci da tsawon lokacin aiki. Wannan busasshen na'ura mai ba da wutar lantarki da kamfaninmu ke samarwa yana da sifofin juriya mai ƙarfi{15}, ƙaramar aikin kulawa, ingantaccen aiki, ƙarami, ƙaramar ƙara, kuma galibi ana amfani dashi a wuraren da ke da babban buƙatun aiki kamar rigakafin gobara da rigakafin fashewa. Amintacce, mai hana wuta, babu gurɓata, ana iya sarrafa shi kai tsaye a cikin babban ƙarfin lodi.
Mun tabbatar da cewa kowane ɗayan rukunin da aka kawo mu ya yi cikakken gwajin karɓa. Muna ba da sabis na fakiti guda ɗaya daga tuntuɓar, ambato, masana'anta, shigarwa, ƙaddamarwa, horarwa zuwa sabis na tallace-tallace bayan{2}. Kayayyakin mu yanzu suna aiki a cikin ƙasashe sama da 50 a duniya. Muna nufin zama mafi amintaccen mai samar da ku da kuma mafi kyawun abokin tarayya a cikin kasuwanci!
1.2 Ƙayyadaddun Fasaha
630 kVA guduro simintin busassun nau'in taswira ƙayyadaddun bayanai da takaddar bayanai
|
Isarwa zuwa
Afirka ta Kudu
|
|
Shekara
2024
|
|
Samfura
630kVA-66.6/0.55kV
|
|
Nau'in
Guduro simintin busassun nau'in taswira
|
|
Babban abu
Silicon karfe takardar hatsi daidaitacce
|
|
Daidaitawa
Saukewa: IEC60076
|
|
Ƙarfin Ƙarfi
630 kVA
|
|
Yawanci
50HZ
|
|
Mataki
Uku
|
|
Nau'in Sanyi
AN/AF
|
|
Babban Voltage
66.6 kV
|
|
Na biyu Voltage
0.55 kV
|
|
Abubuwan Iska
Aluminum
|
|
Impedance
4-4.5%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
± 2 * 2.5% @ ƙarfin lantarki na farko
|
|
Babu Asara Load
1.3KW
|
|
Akan Rasa Load
5.96KW
|
|
Na'urorin haɗi
Daidaitaccen Kanfigareshan
|
|
Matsayin rufi
F
|
1.3 Zane
630 kVA guduro simintin busassun nau'in taswira zane da girman.

02 Masana'antu
2.1 Kori
Don ƙayyadaddun muryoyi don simintin gyaran gyare-gyaren resin, babu -asara, hayaniya da babu{1}} lodin halin yanzu sune mahimman fasalulluka masu inganci waɗanda, a yawancin lokuta, suna da mahimmanci. Don haka, ƙirar ƙira wani muhimmin aikin injiniya ne. Wannan ya haɗa da madaidaicin ƙira na geometrical, ƙayyadaddun kayan kaddarorin kayan maganadisu da za a yi amfani da su da cikakkun bayanai, gami da matakan ƙira irin su waɗanda ke sarrafa rawar jiki, matsayi na slanting da sauran buƙatun injin.
Iron core yana daya daga cikin mahimman abubuwan da ake amfani da su a cikin taswirar, wanda shine sashin da'ira na maganadisu na injin. Na farko da na biyu windings na transformer suna kan baƙin ƙarfe core. Domin inganta ƙarfin maganadisu na da'irar maganadisu da kuma rage hasarar eddy a halin yanzu a cikin ɗigon ƙarfe, yawancin ƙarfen ƙarfe yawanci ana yin shi da takardar ƙarfe na silicon 0.35mm tare da rufin saman. Ƙarfin core ya kasu kashi biyu: ginshiƙin ƙarfe na ƙarfe da karkiya na ƙarfe. An saita iskar gas ɗin akan jigon ƙarfe, kuma karkiya ta ƙarfe tana haɗa ɗigon ƙarfe don samar da rufaffiyar da'irar maganadisu.
2.2 Guda

Simintin gyare-gyare na simintin gyaran gyare-gyare ana siffanta su ta hanyar masu gudanar da iskar HV da suke sawa gaba ɗaya a cikin jikin guduro da ke kewaye tare da santsi. Wurin tanadin thermal saboda rufin farko na musamman yana ba da damar yin lodi. Simintin gyaran fuska na resin yana da vacuum -makullun muryoyin wutar lantarki masu ƙarfi waɗanda aka ƙera iskar su azaman iska mai ninki biyu{3}}Layer winding. Wannan yana nufin aminci a cikin sarrafa ƙarfin lantarki kamar yadda walƙiya ke haifarwa ko ta hanyar da'ira{5}}
Ƙarƙashin wutar lantarki na SCOTECH cast resin transformers kusan koyaushe ana tsara su azaman iska mai iska.
Amfanin wannan nau'i na iskar iska suna bayyana kansu-
● Rage ƙarin asara
● Daidaitaccen rarraba zafin jiki a cikin iska
● Babban gajerar iyawa -
2.3 Taron Karshe
1. Cire saman baƙin ƙarfe karkiya daga stacked baƙin ƙarfe core da goga epoxy guduro a kan core shafi da ƙananan kunnen doki, bukatar epoxy guduro da za a ko'ina mai rufi ba tare da Paint warts, tare da wani kauri na game da 0.5mm, da kuma sanya shi a dakin zafin jiki na halitta curing. Lokacin yin zane, kula da haɗin gwiwar diagonal na ƙarfe na ƙarfe bai kamata a lalata shi da guduro ba.
2. Bayan resin da ke kan tushen baƙin ƙarfe ya warke, sanya ƙananan shingen latsawa, ɗaure babban coil ɗin da majajjawa, kuma saita shi a kan madaidaicin matsayi. Lura cewa tazara tsakanin cibiya da ainihin yakamata ya zama daidai.
3. Daura ƙananan na'urar wutar lantarki - zuwa ginshiƙin ginshiƙi tare da majajjawa, kuma daidaita tazara tsakanin babban na'urar wutar lantarki da babban ginshiƙin. Idan babban tashar iska yana da masu rarrabawa, sanya su kuma daidaita matsayinsu.
4. Tari karkiya na ƙarfe da siffata shi, kuma lebur ɗin ba zai wuce ƙayyadadden ƙima ba.
5. Sanya shingen latsa na sama kuma ka matsa matsi na sama. A goge da resin epoxy kuma a bar shi don ya warke a zafin jiki.
6. Sanya mai sarrafa zafin fan bisa ga buƙatun zane.
7. Haɗa da'irar sarrafawa na mai kula da zafin jiki da fan bisa ga buƙatun zane.
8. Haɗa ƙungiyar haɗin kebul mai girma{1} bisa ga buƙatun zane.

03 Gwaji
Gwajin juriya na insulation: Bincika ikon rufewa na sassan da aka keɓe.
Short{0}}gwajin juriyar kewayawa: Gwada juriyar gajeriyar iskar dawafi.
Juriya na insulation da gwajin ƙarfin lantarki: duba juriyar ƙarfin lantarki na sassan da aka keɓe.
Gwajin wutar lantarki AC: duba juriyar wutar lantarki tsakanin iska da iska, tsakanin iska da ƙasa, da ko akwai fitarwa na ciki a cikin sassan da aka keɓe.
Gwajin jituwa na Ac: duba ƙarfin rufin tsakanin iska da iska da tsakanin iska da ƙasa.
Gwajin ƙarfin rufin saman: Duba ƙarfin rufewa tsakanin iska da harsashi.
Lalacewar kaya kuma babu gwajin hasarar kaya: gwada asarar na'urar da ke ƙarƙashin kaya kuma babu- yanayin kaya.
A'a{0}}gwajin fara lodi: duba aikin fara aikin na'ura mai ɗaukar nauyi-.
Gwajin gwajin ɗan gajeren lokaci -: Duba ikon na'urar watsawa don jure ƙimar ƙarfin lantarki na ɗan gajeren lokaci.
Short{0}}gwajin kewayawa: Duba aikin na'urar watsa labarai a cikin gajeren yanayin da'irar-.


04 Shiryawa da jigilar kaya


05 Yanar Gizo da Takaitawa
Resin simintin bushewa{0}nau'in tafofi yana saita sabon ma'auni a cikin masana'antar tare da fiyayyen aikin sa, ingantaccen ƙira, da ra'ayi na abokantaka{{1}. Bayar da ingantaccen aiki da kwanciyar hankali, tsayin daka na musamman, da daidaitawa ga mahalli masu rikitarwa, ya zama amintaccen ginshiƙi a cikin tsarin wutar lantarki. Ko a cikin masana'antu, ci gaban ababen more rayuwa, ko aikace-aikacen makamashin kore, resin simintin bushewa{4}}nau'in tafsiri yana ba da ƙima mara misaltuwa. Zabar shi ba alƙawarin ba ne kawai ga ingantattun kayan lantarki masu inganci amma kuma mataki ne mai fa'ida zuwa ga mafi wayo kuma mai dorewa nan gaba, yana tabbatar da dorewa da ingantaccen ƙarfi ga kowane amfani.

Hot Tags: simintin guduro busassun nau'in transfoma, masana'anta, mai kaya, farashi, farashi
You Might Also Like
Aika Aikace-aikacen




