650 KVA Cast Coil Transformers-11 / 0.34 KV|Hadaddiyar Daular Larabawa 2025
Yawan aiki: 650kVA
Wutar lantarki: 11000/340V
Siffar: tare da Yadi IP20
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin mafi amintattun masana'antun da masu samar da na'ura mai ba da wutar lantarki 650 kva -11/0.34 kv|Hadaddiyar Daular Larabawa 2025 a China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Tsayayyen ƙarfi ga kowane aikace-aikace - zaɓi scotech cast coil transformers
01 Gabaɗaya
1.1 Bayanin Aikin
Mu 650 kVA Cast Resin Dry -Nau'in Transformer (CRT) yana ba da tsayayye ƙarfi ga matsakaici{2}}ƙaramar wutar lantarki zuwa ƙananan- rarrabawar wutar lantarki. Bi ƙa'idodin IEC. Yana nuna ƙarfin shigarwa na 11kV da ƙarfin fitarwa na 0.34 kV, tare da ƙimar wutar lantarki 650 kVA. Samar da hatsi{10}}madaidaicin silikon karfe da iskar tagulla, injin tafsiri yana aiki lafiya yayin da yake tabbatar da tsawon rayuwa. Ƙungiyar vector Yd11 tana ba da madaidaicin tsaka-tsakin tsaka-tsaki da daidaiton fitowar lokaci guda uku, masu goyan bayan madaidaicin wadatar wutar lantarki.
Na'urar taswira tana amfani da sanyaya AN/AF da F{0}}ajiyar aji, yana ba shi damar yin aiki cikin aminci a ƙarƙashin kaya daban-daban. Babu -asashen lodi shine 1.25 kW kuma asarar nauyi shine 7.3 kW, wanda ke taimakawa rage yawan kuzari. NLTC (No-Load Tap Changer) tare da daidaitawa ± 2×2.5% yana kiyaye ƙarfin wutar lantarki.
1.2 Ƙayyadaddun Fasaha
650kVA Resin simintin busassun nau'in na'ura mai canzawa da takaddar bayanai
|
Isarwa zuwa
Hadaddiyar Daular Larabawa
|
|
Shekara
2025
|
|
Nau'in
Guduro simintin busassun nau'in taswira
|
|
Babban abu
Silicon karfe takardar hatsi daidaitacce
|
|
Daidaitawa
IEC
|
|
Ƙarfin Ƙarfi
650kVA
|
|
Yawanci
50HZ
|
|
Mataki
Uku
|
|
Ƙungiyar Vector
Yd11
|
|
Nau'in Sanyi
AN/AF
|
|
Babban Voltage
11KV
|
|
Na biyu Voltage
0.34 kV
|
|
Abubuwan Iska
Copper
|
|
Impedance
6%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
± 2 * 2.5% @ ƙarfin lantarki na farko
|
|
Babu Asara Load
1.25 kW
|
|
Akan Rasa Load
7.3 kW
|
|
Matsayin rufi
F
|
|
Na'urorin haɗi
Mai sarrafa zafin jiki, Magoya bayan sanyi, Yadi
|
1.3 Zane
650kVA Resin simintin busassun nau'in mai canzawa girma da cikakkun bayanai masu nauyi
![]() |
![]() |
02 Masana'antu
2.1 Kori
An yi ainihin busasshen mu na nau'in tasfoma ({0}}) tare da zanen karfen silicon mai daidaitawa. Yana amfani da ƙirar haɗin gwiwa na mataki - tare da mitred digiri 45, rami{5}}free laminations. Wannan ƙirar ba ta rage asara ba kuma tana rage hayaniya. Transformer yana gudana cikin kwanciyar hankali da kwanciyar hankali.
2.2 Guda
650 kVA simintin coil transformers coils an yi su ne da babban tagulla mai ɗabi'a, suna samar da ƙarfin injina da gajeriyar juriyar kewayawa. Wuraren iska suna amfani da rufin Class F (digiri 155) kuma an tsara su don ingantaccen kariya daga danshi, ƙura, da gajerun da'irori, yana tabbatar da dogon lokaci- amintaccen aiki da kwanciyar hankali.

2.3 IP20 Bayani

Busassun na'urorin mu na cikin gida sun ƙunshi IP20{2}}ananan shinge na kariya, yana ba da cikakkiyar kariya: hana haɗuwa da haɗari tare da manyan abubuwan ƙarfin lantarki, keɓance ƙura da abubuwa na waje, da tsawaita rayuwar sabis na taswira. Har ila yau, shingen da aka rufe yana rage amo mai aiki kuma yana haɓaka jin daɗin aiki na cikin gida. Ƙirar sa mai daɗi da ƙaƙƙarfan tsari yana ba abokan ciniki amintaccen, abin dogaro, kuma mai sauƙi don kiyaye hanyar rarraba wutar lantarki.
2.4 Taron Karshe
Yayin haɗuwa, kowane busassun na'ura{0}} ana sanye shi da na'urar sarrafa zafin jiki da PT100 da aka gina a cikin iska guda uku{2}. Waɗannan suna sa ido kan yanayin iska a ainihin lokacin kuma suna nuna su akan nunin dijital. Manyan magoya bayan sanyaya masu inganci guda shida- suna inganta ɓarkewar zafi da kuma tabbatar da tsayayyen aiki na tsawon lokaci-. Kowane samfurin yana fuskantar gwaje-gwaje masu tsauri da yawa yayin aikin masana'antu kuma ana sake duba shi sosai kafin jigilar kaya. Mun himmatu wajen samar wa abokan ciniki ingantaccen, aminci, da inganci mai inganci-nau'in na'ura mai canzawa{10}}.

03 Gwaji
Matsayin Gwaji da Gwajin Na yau da kullun
IEC 60076-1-2011 Masu Canza wutar lantarki - Kashi na 1: Gabaɗaya
IEC 60076-3-2013 Masu Canza wutar lantarki - Kashi 3: Matakan rufi, gwaje-gwajen dielectric da izinin waje a cikin iska
TS EN 60076-11-2018 RLV Masu Canza wutar lantarki - Kashi 11: Busassun na'urar wuta
1. Auna juriya na iska
2. Ma'auni na ƙarfin lantarki da kuma duba ƙaurawar lokaci
3. Ma'auni na gajere - hanawa da kuma asarar kaya
4. Ma'auni na babu asarar nauyi da halin yanzu
5. Gwajin wutar lantarki da aka yi amfani da shi
6. Gwajin jurewar wutar lantarki da aka haifar
7. Gwajin fitar da bangare


04 Shiryawa da jigilar kaya


05 Yanar Gizo da Takaitawa

Scotech 650 kVA Cast Resin Dry{1} Nau'in Transformer yana ba da aminci da kwanciyar hankali don aikace-aikacen masana'antu da kasuwanci. Yana da silicon karfe core da jan karfe windings cikakkiya an rufe shi da epoxy resin, bada izinin aiki na dogon lokaci{3} ba tare da mai ba.
Transformer yana da ƙungiyar vector Yd11 da No{1}}Load Tap Changer (NLTC) don kiyaye ƙarfin lantarki a ƙarƙashin canza lodi. An/AF sanyaya da rufin Class F suna ba shi damar aiki lafiya a yanayin zafi mai girma. Ƙananan babu - lodi da asarar kaya suna taimakawa rage amfani da makamashi.
Rukunin IP20 yana kiyaye mutane lafiya kuma yana hana ƙura da abubuwa shiga. Gina -a cikin na'urori masu auna zafin jiki da masu sanyaya sanyi suna taimaka wa taswirar gudu da aminci.
Hot Tags: Cast coil transformers, ma'aikata, maroki, farashin, tsada
You Might Also Like
500 kVA Dry Resin Transformer-13.8 / 0.46 kV|Afirka ...
630 kVA Simintin Gudun Busassun Nau'in Canji-66.6/0....
400 kVA Busassun Nau'in Canjin Lantarki-0.55 / 0.46 ...
160 kVA Nau'in Busassun Nau'in Cikin Gida-10 / 0.4 k...
630 kVA Nau'in Busassun Nau'in Rubutun Mataki na Uku...
1500 KVA Matsakaici Nau'in Wutar Lantarki na Busassu...
Aika Aikace-aikacen