2750 KVA Bess Mai Canjawa-34.5 / 0.4 KV|Amurka 2026
Yawan aiki: 2750kVA
Wutar lantarki: 34.5/0.4kV
Feature: tare da mai kamewa
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'anta da masu samar da taswira 2750 kva bess -34.5/0.4 kv|Amurka 2026 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Ƙirƙira don aikace-aikacen BESS, yana isar da abin dogaro, babban juzu'i mai ƙarfi{0} ƙarƙashin grid da yanayin hawan keke.
01 Gabaɗaya
1.1 Bayanin Aikin
Wannan rukunin ya fito ne daga aikin da aka gabatar a farkon 2025, lokacin da wani ɗan kwangilar samar da wutar lantarki na tushen Amurka ya ba da oda don2750 kVA uku -kushin lokaci{2}}wanda aka ɗora tasfoma don BESSGidajan sayarwa A Hinkley, California. Abin da ake bukata ya kasance mai sauƙi a kan takarda{1}mataki matsakaicin ƙarfin lantarki zuwa ƙananan ƙarfin lantarki don ajiyar makamashi da tsarin jujjuyawa{2}amma yanayin aiki ya kasance ƙasa da gafara, na lantarki da muhalli.
The bess transformer da kanta an tsara shi daidai da IEEE Std C57.12.34-2022. An ƙididdige shi a 2750 kVA, tare da firamare 34.5 kV da sakandare 0.4 kV, ƙungiyar vector Dyn1. Cooling shine KNAN, kuma ana amfani da ester na halitta na FR3 azaman ruwan insulating. Babu wani sabon abu a keɓance{9}}amma an haɗa shi tare, tsari ne wanda ya yi daidai da tushen inverter.Tsarin tsarin BESS, Inda kwanciyar hankali, yanayin zafi, da iyakokin aminci duk sun fara da ɗan ƙaranci fiye da na saitin rarraba na al'ada. Tare da ƙugiya na 7.5%, taransfoman yana samar da tsayayyen fitarwa na waya guda uku{2}}sashi huɗu{3}, yana sa ya dace da tsarin inverter{4}} tushen tsarin BESS da kayan haɗin gwiwa.
Wurin shigarwa yana gabatar da:
- Matsanancin yanayin zafi daga -13.2 zuwa digiri 45.7 (ASHRAE 20-shekara dawowa)
- Matsakaicin matakan kuskure na yanzu akan matsakaici -tsarin wutar lantarki (~28 kA)
- Ci gaba da aikin hawan keke na yau da kullun na tsarin grid{0}} sikelin BESS
1.2 Ƙayyadaddun Fasaha
2750 kVA kushin da aka ɗora bess taswirar ƙayyadaddun bayanai da takaddar bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Uku fanni kushin Dutsen transformer
|
|
Daidaitawa
IEEE Std C57.12.34-2022
|
|
Ƙarfin Ƙarfi
2750 KVA
|
|
Yawanci
60HZ
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Mataki
uku
|
|
Nau'in Sanyi
KNAN
|
|
Liquid insulant
Farashin FR3
|
|
Babban Voltage
34.5 kV
|
|
Na biyu Voltage
0.4 kV
|
|
Ƙungiyar Vector
Dyn1
|
|
Abubuwan Iska
Aluminum
|
|
Impedance
7.5%
|
|
Nagarta da Asara Daidaitawa
99.53%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
2.6 kW
|
|
Akan Rasa Load
17.3 kW
|
|
Na'urorin haɗi
kamu kamu
|
1.3 Zane
2750 kVA kushin da aka saka bess transformer zane da farantin suna
![]() |
![]() |
02. Injiniya don Ayyukan BESS
Wannan kushin da aka ɗora bess transformer an ƙera shi ne musamman don aikace-aikacen tsarin adana makamashin baturi (BESS), tare da mahimman fasalulluka na ƙira da aka mayar da hankali kan daidaita tsarin, aminci, da ingantaccen aiki a ƙarƙashin yanayin aiki mai ƙarfi.
2.1 BESS{1}} Kanfigareshan Wutar Lantarki

Naúrar tana ɗaukar matakin firamare na 34.5kV delta da 400/230 V na ƙasan wye sakandare (Dyn1 daidai), yana samar da tsayayyen fitowar waya guda uku{4}}sashe huɗu-fitowar waya da ake buƙata don inverter{6}} tushen tsarin. Ƙirƙirar aluminium mai iska guda biyu-, haɗe tare da 7.5% impedance, tana goyan bayan ingantaccen tsarin tsaro ƙarƙashin manyan matakan kuskure (~ 28 kA) yayin da suke kiyaye daidaiton tsarin gaba ɗaya.
2.2 Zane na thermal da Insulation don lodin keken keke
An ƙera shi don ci gaba da caji / aikin fitarwa, injin taswira yana amfani da sanyaya ruwa na ONAN tare da iyakacin hawan zafin jiki na digiri 65, yana tabbatar da ingantaccen aikin thermal a ƙarƙashin nau'ikan nau'ikan maimaitawa. An inganta tsarin jujjuyawar aluminium don ɓarnar zafi da ƙarfin injina ƙarƙashin gajeriyar yanayi{2}. An ƙera babban taro da haɗakar iska don rage asara da jure yanayin zafi a ƙarƙashin babban aikin BESS na keke.


2.3 Kariya da Haɗin Tsarin
Don saduwa da haƙiƙanin shigarwa na BESS, ba a kula da tsarin kariya azaman ƙarawa ba amma azaman ɓangaren ƙira. The bess transformer an sanye shi da na'ura mai ɗaukar nauyi na ciki, fis ɗin korar bayoneti, da na yanzu{2}}iyakance fis, aiki tare azaman tsarin kariya mai haɗin gwiwa. An haɗa masu kama waɗanda aka ƙididdige su a 24.4 kV MCOV suma an haɗa su{5} musamman don kula da abubuwan da suka shafi wuce gona da iri daga sauyawa ko rikicewar grid, waɗanda ba sabon abu bane a waɗannan tsarin.
Ƙarƙashin ƙasa yana bin ƙaƙƙarfan tsari mai tushe, tare da haɗin kai a babban allon rarrabawa. Daidaitaccen daidaitaccen tsari ne, amma mahimmanci anan{1} yana kiyaye halayen tsarin kuma yana tabbatar da dacewa da tsare-tsare na ƙasa na BESS, musamman a gefen ƙasa.


2.4 Tsarin Wutar Lantarki da Kulawa
An saita tafsifofi da madauki 600 A deadfront madauki{1}} ciyar da bushings a kan babban -gefen wutar lantarki da gefe{3}wanda aka ɗora NEMA 8-rami spade tashoshi akan ƙananan ƙarfin ƙarfin lantarki, yana ba da damar aminci da ingantaccen haɗin gwiwa a tsarin rarraba ƙasa da manyan aikace-aikacen BESS.
An tsara hanyoyin haɗin kebul don ɗaukar 500 kcmil aluminum MV conductors tare da tsaka tsaki mai tsaka tsaki da ƙasa, da kuma layi ɗaya na 1000 kcmil LV igiyoyi, yana tabbatar da abin dogaro na yanzu.


03 Gwaji

Sakamakon Gwaji

04 Shiryawa da sufuri
4.1 Shiryawa


4.2 Shipping

05 Yanar Gizo da Takaitawa
Wannan 2750 kVA pad -wanda aka ɗora tafsiri yana nuna tsarin ƙirar BESS{2}, yana haɗawa:
- Daidaitawa zuwa babban hawan keke da nauyin jituwa
- Ƙarfin aiki mai ƙarfi a ƙarƙashin babban kuskure na halin yanzu
- Ingantaccen aminci ta hanyar rufin FR3
- Cikakken yarda da ka'idojin Arewacin Amurka
Yana ba da ingantaccen ingantaccen bayani don tsarin ajiyar makamashi na zamani da ke aiki a ƙarƙashin grid mai buƙata da yanayin muhalli.
Hot Tags: bess transformer, manufacturer, maroki, farashin, farashi
You Might Also Like
2500 kVA Kushin Haɗa Mai Canjawa-13.2 / 0.48 kV|Kana...
75 kVA Pad Dutsen-23 / 0.208 kV|Amurka 2025
2500 kVA Kushin Dutsen Mai Canjawa-12.47 / 0.48 kV|A...
2500 kVA Masu Canzawa Pad-12.47 / 0.48 kV|Amurka 2025
1000 KVA Mai Cika Mai Sauƙi-21 / 0.48 KV|Amurka 2025
1000 KVA Mai Canjawa-24.9 / 0.48 KV|Amurka 2025
Aika Aikace-aikacen











