750 KVA Kushin Dutsen Mai Canjawa Grounding-13.8 / 0.6 KV|Kanada 2025
Yawan aiki: 750kVA
Wutar lantarki: 13.8/0.6kV
Fasalin: Ƙungiyar Vector DD0
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin ƙwararrun masana'anta kuma masu samar da 750 kva pad Mount transformer grounding -13.8/0.6 kv|kanada 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

750 kVA Pad Dutsen Transformer Grounding - Injiniya don amintaccen kariya ta kuskure, ingantaccen aikin grid, amintaccen tsarin rarraba ƙasa.
01 Gabaɗaya
1.1 Bayanin Aikin
Wannan aikin ya ƙunshi bayarwa na a750 kVA guda uku{1}zuwa Kanada -wanda aka gina a ƙarƙashin buƙatun takaddun shaida na UL kuma yana da cikakken yarda da ka'idojin CSA C227.4:21, mai niyya na dogon lokaci{3}}amincin aiki, tsayayyen grid haɗin gwiwa, da babban abin dogaro a duk wuraren zama, kasuwanci, da hanyoyin rarraba masana'antu; inda ci gaban sabis, da juriya na kuskure, ba na zaɓi bane, amma ana sa ran.
Naúrar tana aiki akan tsarin madauki tare da mataccen ƙira ta gaba{1}}madaidaicin sauyawa, mafi kyawun ware, ƙarin sassauci a tsarin rarraba ƙasa. Yana rage ƙarfin wutar lantarki daga 13.8 kV zuwa 0.6 kV, yana samar da tsaftataccen mahalli mai tsafta tsakanin matsakaici - wadatar wutar lantarki da ƙarancin amfani da wutar lantarki; tsayayyen hali a ƙarƙashin canza yanayin kaya, koda lokacin da buƙata ta canza.
A cikin wannan saitin, ƙirar kushin ɗorawa taswirar ƙasa ƙirar -ba kawai daki-daki ba, amma wani yanki na tsarin dabaru - kai tsaye yana rinjayar kuskuren kulawa na yanzu, kwanciyar hankali na aiki, da daidaitawar kariya. Musamman a madauki{3}} cibiyoyin sadarwa; ci gaba da ƙasa dole ne a riƙe, dole ne a riƙe, in ba haka ba martanin tsarin ya zama mara tabbas.
1.2 Ƙungiyar Vector & Impedance
Mai taswira yana amfani da ƙungiyar vector Dd0, yana ba da ƙayyadaddun ƙayyadaddun lokaci da daidaito tsakanin madauki{1} tsarin ciyarwa, yana tabbatar da aiki daidai gwargwado a cikin cibiyoyin sadarwa masu saukar da kushin masana'antu a matakin 0.6 kV, tare da ingantaccen aiki a ƙarƙashin madaidaicin nauyi da marasa daidaituwa.
Ƙunƙashinsa na 4.75% yana ba da ingantaccen taƙaitaccen kewayawa na yanzu{1} kuma yana goyan bayan ƙayyadaddun ƙa'idodin ƙarfin lantarki, haɓaka aminci gabaɗaya da ƙarfafa aikin tsarin ƙasan taswira a ƙarƙashin yanayin kuskure a cikin CSA C227.4:21 shigarwa masu dacewa.
1.3 Ƙimar Fasaha
750 kVA kushin Dutsen wutan lantarki ƙayyadaddun ƙayyadaddun bayanai da takaddar bayanai
|
Isarwa zuwa
Kanada
|
|
Shekara
2025
|
|
Nau'in
Uku fanni kushin Dutsen transformer
|
|
Daidaitawa
CSA C227.4:21
|
|
Ƙarfin Ƙarfi
750 KVA
|
|
Yawanci
60HZ
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Mataki
uku
|
|
Nau'in Sanyi
ONAN
|
|
Liquid insulant
Ma'adinan Mai
|
|
Babban Voltage
13.8 kV
|
|
Na biyu Voltage
0.6 kV
|
|
Ƙungiyar Vector
dd0
|
|
Abubuwan Iska
Copper
|
|
Impedance
4.75%
|
|
inganci
99.15%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
1.230 kW
|
|
Akan Rasa Load
8.800 kW
|
|
Na'urorin haɗi
Daidaitaccen Kanfigareshan
|
1.4 Zane
750 kVA kushin Dutsen transformer grounding zane da farantin suna
![]() |
![]() |
02 Masana'antu
2.1 Kori

An yi ainihin siliki mai inganci{0}}ƙarfe, yana tabbatar da ƙarancin asarar maganadisu da ingantaccen inganci. Tsarin haɗuwa yana ba da garantin ƙarfin injina da ingantaccen aikin maganadisu. Bayan masana'anta, an nannade asalin tare da fim ɗin filastik mai kariya don hana shigowar danshi, gurɓataccen ƙura, da iskar shaka yayin ajiya da jigilar kayayyaki, yana riƙe da ingantaccen aiki a cikin tsarin shimfidar ƙasa gabaɗaya kushin dutsen wuta.
2.2 Guda
Transformer yana amfani da windings na jan karfe tare da rufin mai na ma'adinai. Tsarin yana goyan bayan ± 2 × 2.5% daidaitawar famfo NLTC, yana tabbatar da ingantaccen fitarwar wutar lantarki a ƙarƙashin yanayin nauyi daban-daban da tallafawa ingantaccen aiki a cikin buƙatun ƙirar ƙirar ƙasa.

2.3 Tanko

Taswirar tana da tankin ƙarfe mai laushi da aka rufe tare da murfin da aka rufe, an gama shi cikin kore kayan aiki (Munsell 9 GY 1.5/2.6) don juriyar lalata da gano filin.
An ƙirƙira shi na dogon lokaci{0} ɗorewa, tankin yana haɗa cikakken tsarin ɗora matattarar wutar lantarki, gami da na'urar taimakon matsa lamba, bawul ɗin magudanar mai tare da aikin samfur, da filogi. Bas ɗin ƙasa mai tsauri tare da tashoshi na spade yana tabbatar da ingantaccen ƙasa, kiyaye cikakken bin ƙa'idodin aminci da ƙarfafa amincin ƙirar tsarin ƙasa.
2.4 Bushings & Tashoshi
Babban -Voltage (HV) Bushings
Bangaren HV yana amfani da filogi guda 3 da aka ware{1} a cikin masu haɗin haɗin da aka ƙididdige 200 A, an sanya su a cikin sashin HV. Tare da 95kV BIL, suna tabbatar da aminci kuma amintaccen haɗi a cikin tsarin madauki{5}}Fed pad Dutsen transformer grounding system, yana ba da ƙarfin juriya da aiki mai ƙarfi.


Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙwara (LV).
Gefen LV yana fasalta guduro guda 3{1} simintin gyare-gyare tare da nau'in tashoshi 4{3}}rami{5}}, masu kima 30 kV BIL, yana tabbatar da amintaccen haɗin haɗin kai mara ƙarfi don rarraba 0.6 kV yayin da yake goyan bayan aikin daskarewa taswira.
Tashar ƙasa
Ƙididdiga tashoshi biyu na ƙasa tare da bas ɗin jan ƙarfe mai tsauri yana tabbatar da cikakken tsarin ɗorawa mai ɗaukar wuta, yana ba da ingantaccen ƙasa ga bangarorin HV da LV, haɓaka ɓarna na yanzu da amincin tsarin gabaɗaya.

2.5 Kayan aiki & Na'urorin haɗi

An sanye da injin na'urar tare da cikakken saiti na saka idanu da kariya, yana tallafawa duka biyun aiki da kushin dutsen wutan lantarki sarrafa aminci:
- Ma'aunin zafin mai don sarrafa zafi
- Ma'aunin man fetur don kwanciyar hankali
- Ma'aunin matsa lamba don saka idanu akan yanayin ciki
- Na'urar taimako na matsin lamba don kariyar tanki
- Bawul ɗin magudanar mai tare da aikin samfur don kulawa
03 Gwaji
Matsayin Gwaji

Sakamakon Gwaji

04 Shiryawa da sufuri
4.1 Shiryawa


4.2 Shipping


05 Shigarwa & Takaitawa
Shigarwa da Gudanarwa
Shigarwa yana bin ƙa'idodin ƙa'idodi, tabbatar da kafaffen jeri, daidaitaccen haɗin wutar lantarki, da aiwatar da shimfidar ƙasa na pad mai kyau. Yin aiki yana tabbatar da amincin rufin, ci gaba da ƙasa, da cikakken amincin aiki kafin ƙarfafawa.
Maɓalli Maɓallin Maɓalli
- Babban inganci (99.15%) yana rage asarar makamashi
- Amintaccen CSA{0}}ƙirar da ta dace don aiki na dogon lokaci-
- Ƙungiyar vector DD0 tana tabbatar da tsayayyen halayen tsarin
- Babban{0}}ƙarar wutar lantarki da ƙarancin wutar lantarki{1} yana tabbatar da haɗin kai mai aminci
- Cikakken kushin dutsen wutan lantarki tsarin ƙasa yana haɓaka amincin kuskure da daidaiton tsarin
- Haɗaɗɗen kayan aikin sa ido don ingancin kulawa
Wannan 750 kVA pad -wanda aka ɗora tafsiri shine ingantaccen abin dogaro kuma ingantaccen mafita ga hanyoyin sadarwa na zamani, yana ba da aikin lantarki mai ƙarfi, ƙirar ƙasa mai ƙarfi, da cikakkiyar yarda da ƙa'idodin aminci na Arewacin Amurka.
Hot Tags: kushin Dutsen transformer grounding, manufacturer, maroki, farashin, farashi
You Might Also Like
2500 kVA Uku Pad -wanda aka ɗora Transformer-13.8/0....
150 kVA Kushin Haɗa Mai Canjawa-34.5 / 0.208 kV|Amur...
500 kVA Kushin Haɓaka Mai Canjin Lantarki-34.5 / 0.4...
150 kVA Ansi Transformer-24.94 / 0.208 kV|Amurka 2024
2000 KVA Bayonet Fuse Pad Mai Canzawa-13.8 / 0.48 KV...
800 KVA Delta Wye Mai Canjin Wuta-34.5 / 0.48 KV|Amu...
Aika Aikace-aikacen