2000 KVA Cooper Power Systems Pad Haɗa Masu Canza-33.26 / 0.48 KV|Amurka 2025
Yawan aiki: 2000 kVA
Wutar lantarki: 33.26/0.48kV
Feature: tare da mai kama
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'antun da masu samar da tsarin wutar lantarki na kva 2000 kva cooper pad mounted transformers{6}33.26/0.48 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Pad -Masu Canzawa: Inda Injiniya Mai Dorewa Ya Haɗu da Rarraba Wayo.
01 Gabaɗaya
1.1 Bayanin Aikin
2000 kVA three phase pad mounted transformer an isar da ita zuwa Amurka a shekarar 2025. Ƙarfin wutar lantarkin shine 2000 kVA tare da sanyaya KNAN. Babban ƙarfin lantarki shine 33.26GrdY / 19.203 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.48Y / 0.277 kV, sun kafa ƙungiyar vector na YNyn0.
An keɓance don yanayin hasken rana, ajiyar makamashi, kasuwanci, da yanayin rarrabuwar masana'antu, SCOTECH's cooper power system pad ɗorawa na'urorin wuta yana haɗa ingantaccen aiki da mai amfani{0}}ƙirar tsakiya don saduwa da buƙatun rukunin yanar gizo daban-daban. Its 3{5}}phase 5- ginshiƙi na gaba da DOE{10}}ƙwararru masu dacewa suna haɓaka amfani da makamashi, fa'ida mai mahimmanci ga tsarin makamashi mai sabuntawa inda kowane watt ya ƙidaya. Amfani da ruwan FR3 yana kawar da hadurran gobara da haɗarin muhalli, yana mai da shi tafi{11}}don zaɓin shigarwa kusa da wuraren zama, cibiyoyin bayanai, da ayyukan makamashin kore. Gina{12}}masu kame masu yawan gaske suna garkuwa da na'ura mai taswira daga magudanar wutan lantarki{13}} dole ne{15}} yana da fasalin fakitin waje{16}}saitin da aka ɗora akan yanayin da ba'a iya faɗi. Gefen {18} ɗorawa na mitoci yana daidaita ayyukan rukunin yanar gizon, daga saka idanu akan kaya zuwa duban kulawa, yayin da sleek RAL 9003 foda -fararen gamawa mai rufaffiyar ƙura yana tsayayya da lalata UV, tsatsa, da lalata sinadarai, yana tabbatar da kyawawan halaye da ayyuka na dogon lokaci. Ko don gonakin hasken rana da ke daure ko kuma wuraren kasuwanci na birni, wannan taransifoma yana ba da ƙarfi, rarraba wutar lantarki mai dorewa.
1.2 Ƙayyadaddun Fasaha
2000 kVA cooper ikon tsarin kushin saka tasfo bayanai dalla-dalla nau'in da bayanai takardar
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
IEEE Std C57.12.34-2022
|
|
Ƙarfin Ƙarfi
2000 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
KNAN
|
|
Babban Voltage
33.26GrdY/19.203kV
|
|
Na biyu Voltage
0.48Y/0.277 kV
|
|
Abubuwan Iska
Aluminum
|
|
Ƙungiyar Vector
YNyn0
|
|
Impedance
5.75%
|
|
inganci
99.51%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
1.95 kW
|
|
Akan Rasa Load
13.15 kW
|
1.3 Zane
2000 kVA kushin da aka ɗora zane da girman hoto.
![]() |
![]() |
02 Masana'antu
2.1 Kori

Babban ƙarfe na tsarin wutar lantarki na cooper wanda aka ɗora tasfoma an yi shi tare da manyan lamintattun sanyi{1}}waɗanda aka yi birgima na silicon karfe, wanda aka ƙera don rage yawan asarar da ake yi a halin yanzu. Yana samar da da'irar maganadisu na mai canzawa don ingantaccen tafiyar da motsi, yana ba da goyan bayan injina don iska, kuma yana fasalta ingantaccen ƙasa don tabbatar da aminci, barga aiki tare da ingantaccen ƙarfin kuzari.
2.2 Guda
Nada (winding) na cooper power system pad ɗora tasfotoci an yi shi ne da tagulla/aluminum madugu da aka raunata cikin manyan sassan wutar lantarki (HV) da ƙananan{1}}ƙaramar wutar lantarki (LV), an naɗe su da kayan kariya masu ƙarfi (kamar takarda da aka liƙa) don keɓewar lantarki. Rauni a kusa da ainihin, yana bin ka'idodin IEEE/ma'auni na thermal (wanda aka daidaita da ruwa{3}} muhallin da aka nutsar da shi), yana tabbatar da kwanciyar hankali na inji a kan shigarwa/matsi na aiki, kuma yana ba da ingantaccen jujjuyawar wutar lantarki da watsa wutar lantarki.

2.3 Tanko

Tankin tsarin wutar lantarki na cooper wanda aka ɗora tasfotoci welded ne, shingen shinge na ƙarfe wanda aka tsara don waje, ƙasa - matakin shigarwa. Yana dauke da hadaddiyar cibiya da coil kuma yana cike da ko dai man ma'adinai ko ƙasa da - ruwa mai wuta mai ƙonewa don rufewa da sanyaya. Tankin yana da ƙarfi kuma yana jurewa{4}}, tare da ƙananan bayanan{5}}, yawanci ribbed ko ƙirar ƙira don ƙara ƙarfi da ɗumamar zafi. Dukkan sassa masu rai suna cikin tsaro a rufe, yayin da na waje, ɗakunan da za a iya kulle su suna ba da dama ga haɗin kebul na farko da na sakandare, bushings, da na'urorin kariya, suna tabbatar da aminci ga jama'a da ma'aikatan amfani.
2.4 Sashe Mai Aiki
Bangaren aiki (core taro) na cooper power system pad ɗin da aka ɗora tasfoma a cikin hoton shine hadedde ɓangarorin ginshiƙi: ya ƙunshi iska guda uku - (naɗe da nannaɗe cikin kayan rufewa) waɗanda aka ɗora akan madaidaicin ƙarfen ƙarfe, haɗe tare da madaidaitan wayoyi na gubar (wanda aka haɗa don tsari) da firam ɗin tallafi na ƙarfe. Wannan taron an gyara shi kuma an keɓe shi don tabbatar da daidaiton daidaitawar wutar lantarki tsakanin cibiya da iska, yayin da jagororin ke ajiye musaya don haɗa abubuwan waje, suna shirya shi don shigarwa cikin tankin na'ura mai canzawa{3} duk sun dace da matakan lantarki da kwanciyar hankali.

03 Gwaji
Pad - na'urorin wuta da aka ɗora ana yin gwaje-gwaje masu tsauri don tabbatar da aminci da aminci. Waɗannan sun haɗa da gwaje-gwaje na yau da kullun akan kowace naúra, kamar ma'aunin juriya, jujjuyawar gwaje-gwaje, tantancewar polarity, da babu- ma'aunin nauyi/asara. Bugu da ƙari, ana fuskantar gwajin dielectric, gami da amfani da wutar lantarki da yuwuwar gwaje-gwaje, don tabbatar da ingancin rufin. Duk raka'a dole ne su wuce na'urorin haɗi da na'urori masu aiki kamar masu canza famfo, da kuma na'urorin sarrafawa na ƙarshe. Nau'in gwaje-gwaje, gami da haɓakar zafin jiki da gajeriyar gwajin jurewar yanayi{6}, ana yin su akan raka'o'in wakilai don tabbatar da ƙira.


04 Shiryawa da jigilar kaya
4.1 Shiryawa

Kunshin tsarin wutar lantarki na cooper wanda aka ɗora tafsiri yana manne da ƙa'idodin ƙasashen duniya da aiwatarwa{0} takamaiman buƙatu, ta amfani da firam ɗin katako mai ƙyalƙyali ko ingantattun firam ɗin ƙarfe tare da buffers masu hana girgiza (kumfa/roba) don amintar tanki, bushings, da na'urorin haɗi. Ya haɗa da kariya da aka rufe daga danshi/tsatsa, daidaitaccen lakabi (alamomin faɗakarwa, bayanan samfur, "Ayyukan Tsayayya"/"Alamomin Tsatsa") wanda aka liƙa a kowane takamaiman matsayi, da amintaccen ɗaure don kwanciyar hankali yayin tafiya, yana tabbatar da cewa naúrar ta kasance cikakke har zuwa bayarwa.
4.2 Shipping
Jirgin DDP na tsarin wutar lantarki na cooper wanda aka ɗora tasfoma yana buƙatar mai siyarwa ya ɗauki cikakken alhakin ƙarfi, mai jujjuyawa, da danshi{0}marufi mai ƙarfi (karewar cibiya, windings, tanki, da na'urorin haɗi), zaɓi jigilar teku/kasa wanda ya dace da kayan aiki masu nauyi, cikakken izinin kwastam, rufe duk ayyuka da haraji, bin IMDG, DOT, da canza yanayin isar da ƙa'idodin sufuri na ƙasa da ƙasa. wurin da aka keɓance don shirya{1}}don shigar da amfani.

05 Yanar Gizo da Takaitawa
A SCOTECH, faifan mu da aka ɗora tasfofi{0} yana tsaye a matsayin maƙasudin aminci, inganci, da ƙwarewar injiniya a tsarin rarraba wutar lantarki. An gina shi tare da cikakken rufaffiyar, lalata{2}}tsari mai juriya da ci-gaba -asashen fasahar hasara, suna isar da daidaito, aiki mara yankewa tare da ƙaramar kulawa, rage farashin aiki da raguwar lokacin rayuwarsu gaba ɗaya.
Muna ba da fifiko ga daidaito da sassauci a kowace naúrar da muke kerawa. Daga ƙimar ƙarfin lantarki na al'ada zuwa ingantattun fasalulluka na aminci, ƙungiyarmu tana aiki tare don samar da mafita waɗanda suka dace da ainihin ƙayyadaddun bayanai na fasaha da buƙatun aiki. An goyi bayan tsauraran matakan sarrafa ingancin inganci da cikakken goyon bayan tallace-tallace{2}, taswirar mu shaida ne ga jajircewarmu na isar da kimar dogon lokaci da kwanciyar hankali ga kowane abokin ciniki. Zaɓi SCOTECH don tasfomai waɗanda ba su cika ka'idojin masana'antu ba kawai-suna saita su. Haɗin gwiwa tare da mu, kuma bari ƙwarewarmu ta ba da ƙarfin buƙatun abubuwan samar da wutar lantarki mafi mahimmanci.

Hot Tags: cooper ikon tsarin kushin mounted transformers, manufacturer, maroki, farashin, farashi
You Might Also Like
2500 kVA Residential Electrical Transformers-34.5/0....
500 kVA Kushin Dutsen Mai Canjawa-13.8 / 0.48 kV|Amu...
400 kVA Padmount Transformer-23 / 0.4 kV|Chile 2024
500 kVA Utility Pad Hawan Canji-24 / 0.48 kV|Amurka ...
2000 KVA Centrepoint Energy Pad Hawan Canji-24.9/0.4...
2000 KVA Bayonet Fuse Pad Mai Canzawa-13.8 / 0.48 KV...
Aika Aikace-aikacen