500 kVA Kushin Dutsen Mai Canjawa-13.8 / 0.48 kV|Amurka 2025

500 kVA Kushin Dutsen Mai Canjawa-13.8 / 0.48 kV|Amurka 2025

Ƙasa: Afirka ta Kudu 2025
Yawan aiki: 500kVA
Wutar lantarki: 13.8/0.48 kV
Feature: tare da IFD
Aika Aikace-aikacen

 

 

pad mount transformer

Kyawawan inganci, manyan fasaha{0}Bari guda uku{1}}wayoyin da aka ɗora su{2}} su samar muku da mafi kyawun hanyoyin samar da wutar lantarki!

 

01 Gabaɗaya

1.1 Fagen Aikin

500 kVA uku pad mounted transformer an isar da ita zuwa Amurka a shekarar 2025. Ƙarfin wutar lantarkin shine 500 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 13.8D kV, ƙarfin lantarki na biyu shine 0.48y / 0.277 kV tare da ± 2 * 2.5% tapping range (NLTC), sun kafa ƙungiyar vector na Dyn11.

Na'urar gano kuskuren cikin gida (IFD) tana ci gaba da lura da yanayin taswirar na yanzu, ƙarfin lantarki, da zafin jiki, yana ba shi damar gano kurakuran wutar lantarki da sauri da ma'aikatan kula da faɗakarwa ta hanyar ƙararrawa na gani da na ji. Ƙirar taswirar tana ba da fifikon amincin ma'aikata, tare da duk hanyoyin haɗin lantarki da ke da ƙorafi da sanye take da kofofin aminci don tabbatarwa da dubawa. SCOTECH uku -madaidaicin kushin da aka ɗora wutar lantarki ana amfani da shi sosai a cikin rarraba wutar lantarki na birane, wuraren kasuwanci, samar da masana'antu, da al'ummomin zama, yana mai da shi wani yanki mai mahimmanci na hanyoyin sadarwar wutar lantarki na zamani. Yana da kyau musamman-ya dace da haɗin kai tare da tsarin kebul na ƙasa, yana ba da ingantattun hanyoyin samar da wutar lantarki don ababen more rayuwa na birane.

 

 

1.2 Ƙayyadaddun Fasaha

500 KVA kushin da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai

Isarwa zuwa
Amurka
Shekara
2025
Nau'in
Tashin wutar lantarki
Daidaitawa
DOE 2016
Ƙarfin Ƙarfi
500KVA
Yawanci
60HZ
Mataki
3
Ciyarwa
Radial
Gaba
Rayuwa
Nau'in Sanyi
ONAN
Babban Voltage
13.8D kV
Na biyu Voltage
0.48Y/0.277 kV
Abubuwan Iska
Aluminum
Matsala ta kusurwa
Dyn1
Impedance
5%(±7.5%)
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
0.65 kW
Akan Rasa Load
4.36 kW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

500 kVA kushin da aka ɗora zane da girman hoto.

pad mount transformer diagram drawing pad mount transformer nameplate

 

 

02 Masana'antu

2.1 Live gaba

Live Front ƙirar ƙira ce inda aka fallasa manyan tubalan tasha masu ƙarfin lantarki (a bayyane kuma ana iya samun damar kai tsaye); kayan aikin lantarki ta amfani da wannan ƙira suna ba da damar tuntuɓar kai tsaye (kariya ta kayan rufewa kamar hannayen roba), bayar da haɗin kebul mai sassauƙa (daidaita da buƙatun samun wutar lantarki daban-daban), buƙatar ƙwarewar manyan ma'aikata/natsuwa (don amintaccen aiki tare da manyan ɓoyayyun ƙarfin lantarki), da dacewa da takamaiman yanayin yanayi (misali, samar da wutar lantarki na wucin gadi) na buƙatar wiring ko gyare-gyare akai-akai.

20251203084440871177

 

2.2 radial abinci

20251203084907873177

Pad mounted's transformer's radial feed (nau'in tasha) shine tsarin samar da wutar lantarki inda wutar lantarki ke aiki azaman kumburin tsakiya, kuma ana isar da wutar zuwa raka'o'in lodi da yawa ta hanyar layi daban-daban, masu haskakawa (kamar yadda aka nuna a cikin zane: transfomer a cibiyar yana haɗa kai tsaye zuwa kowane kaya ta hanyar kewayawa mai zaman kanta).

Mahimman halayensa sun haɗa da: tsari mai sauƙi da ƙarancin kuɗi, amma ba tare da wasu hanyoyin wuta ba{0}}idan kowane layi ɗaya ya gaza, nauyin da ya dace zai rasa wuta (tunda babu hanyar samar da ajiya).

 

2.3 Tanko

An gina tankin mai daga ƙarfe mai ƙarfi{0}ƙarar carbon, wanda ke ba da ingantattun kayan inji, juriyar zafin jiki, da juriya na lalata. Transformer da sassan ana fentin su da fenti na farko. Launi na waje shine ma'aunin ANSI #70 mai walƙiya launin toka mai walƙiya don jure yanayin masana'antu tare da bayyanar sulfur dioxide. Tankin mai yana sanye da bawuloli masu aminci don sauke matsanancin matsa lamba na ciki, hana tsagewa ko zubewa saboda wuce gona da iri.

 high-strength carbon steel

 

2.4 Taron Karshe

20251203085800878177

Tsarin IFD (Internal Fault arc Detection) a pad{0}}masu tafsirin wutan lantarki wani muhimmin yanayin tsaro ne da aka tsara don ganowa da kuma rage kurakuran da ke haifar da gunaguni na ciki. Yana amfani da hadedde matsa lamba da/ko na'urorin firikwensin haske don gano yanayin kuskure nan take, yana haifar da ɓarke ​​​​na sama ko fis a cikin millise seconds. A lokaci guda, an gina -a cikin matsuguni na taimakon matsa lamba a amince da isar gas mai fashewa daga ma'aikata da kayan aiki. Wannan kariyar da aka haɗa tana hana fashewar tanki mai bala'i, yana ƙunshe da kuskure, yana haɓaka amincin jama'a a wuraren da jama'a ke da yawa, kuma yana rage lalacewar na'urar da ke kewaye da grid na lantarki.

 

 

03 Gwaji

Gwajin pad{0}}masu tafsiriya haɗa da manyan matakai guda uku: gwajin masana'anta na yau da kullun akan kowace naúrar (juriyawar rufi, juriya, juriya, juriya, babu{0}} ma'aunin nauyi/asara, da gwajin ƙarfin lantarki), nau'in gwaje-gwaje don ingancin ƙira (haushin zafin jiki, juriya, da gajeriyar iya kewayawa), da gwaje-gwajen karɓar filin bayan shigarwa (binciken insulating ruwa, bincike na na'urar kariya). Duk gwaje-gwaje sun bi ka'idodi kamar IEEE C57.12.00 don tabbatar da aikin lantarki, amincin injina, da aminci da aminci na tsawon lokaci{4}.

high voltage bushing
low voltage bushing

 

 

04 wasu

4.1 bayonet fuse

Fus ɗin bayoneti shine fiusi na yanzu{0}}iyakance tare da filogi{1}a cikin ƙira, wanda aka shigar akan babban gefen ƙarfin lantarki azamanmadadin kariyakan kuskuren ciki ko na sakandare{0}} mai tsanani. Itsbayoneti{0}}tsarar lambar sadarwayana ba da damar amintaccen, maye gurbin da hannu bayan haɓakawa{0}. Fis yana bayarwahalin yanzu - iyakancewar katsewadon yanke hanzari mai girma - ma'aunin kuskure, yana hana lalacewa ta hanyar wuta. Yawanci ya haɗa da anuna alama(misali, maɓuɓɓugar ruwa -wanda aka ɗora nauyi) don bayyana kuskure. An daidaita ƙimar fius ɗin tare da iyawar injin tafofi da gajeriyar tsari{4}}matakin kewayawa don tabbatar da zaɓin aiki tare da kariya ta sama, tana ba da mafita mai sauƙi kuma amintaccen kariya ta waje.

20251203085800879177

 

4.2 babu PCB

20251203085759877177

"Babu PCB"yana nufin sashin ya ƙunshibabu polychlorinated biphenyls. PCBs sun kasance ruwan dare gama gari a cikin dielectric da ruwa mai sanyaya amma yanzu an hana su a duniya saboda tsananin gubarsu, dagewar muhalli, da kuma tarukan halittu. A maimakon haka ana amfani da tasfoma na zamanimadadin muhalli amintattukamar PCB{0}man ma'adinai na kyauta, esters roba, ko siliki{1} tushen ruwa don rufewa da sanyaya. Wannan nadi yana tabbatar da ƙayyadaddun samfurin tare da ƙaƙƙarfan ƙa'idodin muhalli da aminci (misali, EPA/TSCA) kuma yana nuna alƙawarin kare lafiyar ɗan adam da yanayin muhalli a duk tsawon rayuwar taswira.

 

 

05 Yanar Gizo da Takaitawa

A cikin tsarin wutar lantarki na zamani, ɗimbin wutar lantarki guda uku{0}masu ɗaure{1} tasfomar ta fito a matsayin maɓalli mai mahimmanci don rarraba wutar lantarki, godiya ga ƙaƙƙarfan aiki da ingantaccen ƙira. Pad ɗin mu{3}}wayoyin da aka ɗora tafsiri suna amfani da fasahar ci-gaba da manyan kayayyaki{4}}, suna tabbatar da ingantaccen aiki a wurare daban-daban. Ko a cikin cibiyoyin rarraba birane ko wuraren masana'antu, zaku iya dogaro da samfuranmu don samar da ingantaccen tallafi na wutar lantarki. Ta zabar mu uku -madaidaicin kushin da aka ɗora tafsiri, za ku sami ƙima mai ɗorewa da sabis mara misaltuwa. Bari mu yi aiki tare don ƙirƙirar kyakkyawar makoma don rarraba wutar lantarki!

transformer painting color

 

Hot Tags: pad Dutsen transformer, manufacturer, maroki, farashin, farashi

Aika Aikace-aikacen