2000 KVA Mai Canja wutar lantarki Akwatin-12.47 / 0.48 KV|Amurka 2025
Yawan aiki: 2000 kVA
Wutar lantarki: 12.47/0.48 kV
Feature: tare da FR3 Oil
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin masana'antun da suka fi dacewa da masu samar da wutar lantarki na 2000 kva -12.47/0.48 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Amincewar Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙasa. Pad -Masu Taswira.
01 Gabaɗaya
1.1 Bayanin Aikin
2000 kVA three phase pad mounted transformer an isar da ita zuwa Amurka a shekarar 2025. Ƙarfin wutar lantarkin shine 2000 kVA tare da sanyaya KNAN. Babban ƙarfin lantarki shine 12.47GrdY / 7.2 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.48Y / 0.277 kV, sun kafa ƙungiyar vector na YNyn0.
A matsayin mahimmin sashi a cikin hanyoyin rarraba wutar lantarki na zamani, injin da aka ɗora taswira an ƙera shi don isar da ingantaccen juzu'in wutar lantarki da rarraba wutar lantarki don aikace-aikacen zama, kasuwanci, da masana'antu. Wannan na'urar taswira ta yi fice tare da ƙirar sa ta muhalli da aminci, mai ɗauke da FR3 na ester insulation oil -wani mai sabuntawa, mai saurin lalacewa wanda ke kawar da haɗarin muhalli da ke tattare da man ma'adinai na gargajiya. Man FR3 ba wai kawai yana alfahari da keɓantaccen lafiyar wuta ba (tare da walƙiya da maki wuta sau biyu na man ma'adinai) amma kuma yana tsawaita rayuwar takardan rufi har zuwa sau takwas, yana tabbatar da kwanciyar hankali na tsawon lokaci-. Mai bin ƙaƙƙarfan ƙa'idodin ingancin makamashi na DOE, yana rage asarar makamashi kuma yana rage farashin aiki sosai. An sanye shi da ginannen mai kamawa, yana kiyayewa yadda ya kamata daga hawan wutar lantarki da wuce gona da iri, yayin da hadedde garkuwar tana haɓaka aikin rufewa da rage haɗarin fitarwa. Akwatin ma'aunin da aka ɗora a gefen{10} yana samar da dacewa daidai{11}}lokacin sa ido kan mahimman sigogin aiki, tabbatar da kulawa akan lokaci da gano kuskure. An gama shi da foda{13}} fenti mai rufi (RAL 9003), injin ɗin yana ba da kyakkyawan juriyar yanayi da kariyar lalata, yana sa ya dace da wurare daban-daban na waje. Wannan kushin da aka ɗora tafsiri shine mafi kyawun zaɓi ga masu amfani waɗanda ke ba da fifikon dorewar muhalli, amincin aiki, da kuma dorewa{16} dorewa.
1.2 Ƙayyadaddun Fasaha
2000 kVA kushin da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
IEEE Std C57.12.34-2022
|
|
Ƙarfin Ƙarfi
2000 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
KNAN
|
|
Babban Voltage
12.47GrdY/7.2kV
|
|
Na biyu Voltage
0.48Y/0.277 kV
|
|
Abubuwan Iska
Aluminum
|
|
Ƙungiyar Vector
YNyn0
|
|
Impedance
5.75%
|
|
inganci
99.51%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
1.95 kW
|
|
Akan Rasa Load
13.15 kW
|
1.3 Zane
2000 kVA kushin da aka ɗora zane da girman hoto.
![]() |
![]() |
02 Masana'antu
2.1 HV Neutral (H0)

Maɗaukakin tsaka-tsakin matsakaicin matsakaici na wannan kushin da aka ɗora na'urar wuta ana fito da shi azaman H0 daban-daban, ƙira da gangan wanda ke sauƙaƙe daidaitawar ƙasa, yana sauƙaƙa akan -aiki na ƙasa da kiyayewa, kuma yana haɓaka amincin aiki. Wannan tsari yana ba da damar madaidaicin iko akan yuwuwar madaidaicin tsaka tsaki, yadda ya kamata yana kawar da haɗarin wuce gona da iri, kuma ba tare da ɓata lokaci ba yana ɗaukar buƙatun ginshiƙan wutar lantarki daban-daban (kamar tsarin TN, TT), yana mai da na'ura mai canzawa zuwa kewayon rarraba birane, wurin shakatawa na masana'antu, da aikace-aikacen gini na kasuwanci.
2.2 LV Tsakanin Bushing (X0)
Ƙarƙashin tsaka-tsakin tsaka-tsakin wutar lantarki na kushin da aka ɗora wutar lantarki an saita shi tare da keɓaɓɓun bushings guda biyu don ayyuka daban-daban: bushing ɗaya yana shimfiɗa garkuwa a tsaye daga cikin tanki kuma yana ƙasa cikin aminci a cikin sashin LV, yadda ya kamata ya rage haɗarin fitarwa na ɓarna da haɓaka aikin rufewar na'urar; ɗayan bushing ana amfani dashi na musamman don fitar da wurin tsaka tsaki na LV, yana ba da damar daidaita saitunan mahaɗin tsaka tsaki don saduwa da buƙatun ƙasa na tsarin rarraba daban-daban.

2.3 Matsayi Hudu Loadbreak Canjawa

Maɓalli guda huɗu{0}maɓallin ɗaukar nauyi na kushin da aka ɗora tafsiri yana da mahimmanci akan -waɗanda aka haɗa kayan sauya kayan aiki tare da saitattun wurare guda huɗu, waɗanda aka ƙera don ba da damar amintattun ayyukan sauyawa (kamar ƙa'idar wutar lantarki, ikon kunnawa da kashewa, ko kariyar ƙasa) ƙarƙashin yanayin lodi ba tare da katse wutar lantarki gaba ɗaya ba. Injiniya don dacewa da halayen aiki na kushin ɗora tafsiri a cikin hanyoyin rarraba birane, wuraren shakatawa na masana'antu, da wuraren kasuwanci, wannan canjin yana fasalta tsari mai ƙarfi, ingantaccen aikin rufewa, da madaidaicin matsayi, yana tabbatar da karko lamba da ƙarancin juriya yayin tafiyar matakai. Tsarin matsayinsa guda huɗu- yana ba da sauƙin daidaitawa zuwa yanayin yanayi daban-daban da buƙatun daidaita wutar lantarki, yayin da ƙarfin ɗaukar nauyi yana kawar da buƙatar katsewar wutar lantarki yayin canjin matsayi{5} yadda ya kamata yana haɓaka ci gaba da samar da wutar lantarki da aminci. Bugu da ƙari, yana biyan aminci da buƙatun muhalli na waje ko mahallin shigarwa, yana ba da mafita mai ɗorewa da ingantacciyar hanyar sauyawa don tsarin taswira masu ɗorawa.
2.4 Tushen Busbar Copper
Motar bus ɗin jan karfe da aka ɗora na pad{0}magudanar wutar lantarki shine ƙaƙƙarfan madugu na tagulla wanda aka girka a cikin shingen don samar da wuri gama gari. Yana haɗa tankin na'ura mai canzawa, babban{2} da ƙananan- wuraren saukar da wutar lantarki, garkuwar kebul, da na'urorin kariya masu ƙarfi, yana tabbatar da ƙaramin-hanyar hanawa zuwa ƙasa. Wannan mashin ɗin yana haɓaka amincin ma'aikata da kariyar kayan aiki ta hanyar watsar da kuskure da igiyoyin walƙiya yadda ya kamata.

2.5 1''magudanar ruwa mai 3/8'' samfuri

An sanye tafsirin tare da ƙaƙƙarfan bawul ɗin magudanar ruwa mai inci 1{6} mai ɗauke da haɗaɗɗiyar tashar samfur mai inci 3/8, wanda aka ƙera don sauƙaƙe bincike da kiyaye ruwan dielectric na yau da kullun; Bawul ɗin 1-inch yana ba da izini don ingantaccen cirewar da aka tara ko sludge daga ƙasan tanki, yayin da 3/8-inch sampler yana ba da sadaukarwa, ƙarami-haɗe-haɗe don cire samfuran mai na wakilai ba tare da zubar da sashin ba, yana tabbatar da amincin aiki duka da bin ka'idodin gwajin bincike.
03 Gwaji

04 Shiryawa da jigilar kaya


05 Yanar Gizo da Takaitawa
A taƙaice, SCOTECH's pad - na'urorin wuta da aka ɗora sun tsaya a matsayin ma'auni na aminci, inganci, da dorewa don cibiyoyin rarraba wutar lantarki na zamani{1} ko an haɗa su cikin grid masu amfani na birni, rukunin kasuwanci, ko tsarin sabunta makamashi kamar hasken rana da wuraren ajiyar makamashi. An ƙera su don saduwa da ƙaƙƙarfan ƙa'idodin ƙasa da ƙasa ciki har da IEEE C57 da CSA C227.4:21, waɗannan na'urori masu canzawa suna ba da daidaiton aiki a cikin matsanancin yanayi na waje, rage ƙarancin kulawa, da tabbatar da aminci, ingantaccen samar da wutar lantarki shekaru da yawa. Tare da goyan bayan shekaru da dama na SCOTECH - ƙwarewar ƙwararrun masana'antar taswira, kowane yanki shaida ce ga jajircewarmu ga inganci da gamsuwar abokin ciniki. Zaɓi SCOTECH pad - na'urorin wuta da aka ɗora, kuma ku yi haɗin gwiwa tare da amintaccen mai bayarwa don ƙarfafa ayyukanku da kwarin gwiwa da kwanciyar hankali.

Hot Tags: akwatin wutar lantarki, masana'anta, mai kaya, farashi, farashi
You Might Also Like
112.5 kVA Kushin Haɓakawa-34.5 / 0.208 kV|Amurka 2024
300 kVA Pad -wanda aka ɗora Transformer-34.5/0.208 k...
400 kVA Padmount Transformer-23 / 0.4 kV|Chile 2024
300 kVA Green Akwatin Mai Canjawa-12 / 0.12 * 0.24 k...
1000 kVA Mai Cika Man Fetur Mai Sauƙi Mai Sauƙi-13.8...
225 kVA Kushin Haɗa Mai Canjawa-34.5 / 19.92 kV|Amur...
Aika Aikace-aikacen