112.5 kVA Kushin Haɓakawa-34.5 / 0.208 kV|Amurka 2024
Yawan aiki: 112.5 kVA
Wutar lantarki: 34.5/0.208 kV
Feature: tare da bayoneti fuse

Daga tushe zuwa ƙarshen ƙarshen, pad - ɗorawa na wuta yana ƙarfafa kowace kilowatt{1}}awa.
01 Gabaɗaya
1.1 Fagen Aikin
112.5 kVA uku fase pad mounted transformer an isar da ita zuwa kasar Sin a shekarar 2024. Matsakaicin karfin wutar lantarkin shine 112.5 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 34.5GrdY / 19.92kV tare da ± 2 * 2.5% tapping range (NLTC), ƙarfin lantarki na biyu shine 0.12 / 0.208kV, sun kafa ƙungiyar vector na YNyn0.
Uku{0}Phase Pad{1}Mounted Transformer shine na'urar rarraba wutar lantarki da ake amfani da ita sosai a tsarin rarraba, da farko tana ba da wuta ga wuraren zama, gundumomin kasuwanci, wuraren shakatawa na masana'antu, da sauran wurare. The uku -fase pad -wanda aka ɗora tasfoma yana karɓar makamashin lantarki ta wurin girmansa{5}}kuma yana saukar da babban ƙarfin wutar lantarki zuwa ƙaramin wuta don wadata kayan lantarki. Babban gefen wutar lantarki yana yawanci haɗe ta hanyar hanyar sadarwa ta zobe ko ciyarwar tasha, yayin da ƙaramin{8}}arfin wutar lantarki ke ba da ƙarfi ga lodi. Maɓallan kaya na ciki da fuses suna ba da kariya don tabbatar da amincin aiki na kayan aiki. Fuses da tashoshi na kebul an haɗa su cikin ɗakin kebul iri ɗaya, tare da ingantaccen ƙirar sararin samaniya yana tabbatar da sauƙi don aiki da kulawa. Tsarin gudanarwa mai haɗa fius da tashar tashar USB an ƙera shi daidai, ta amfani da manyan kayan aiki (misali, azurfa{15}}wararren jan ƙarfe) da ainihin fasahar sadarwar don rage juriyar lamba da tabbatar da kyakkyawan aikin lantarki.
1.2 Ƙayyadaddun Fasaha
112.5 KVA nau'in ƙayyadaddun bayanai da takaddun bayanai
|
Isarwa zuwa
Kanada
|
|
Shekara
2024
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
ANSI Standard
|
|
Ƙarfin Ƙarfi
112.5 KVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
ONAN
|
|
Babban Voltage
34.5GrdY/19.92 KV
|
|
Na biyu Voltage
0.12/0.208 KV
|
|
Abubuwan Iska
Aluminum
|
|
Matsala ta kusurwa
YNyn0
|
|
Impedance
3.5%(±7.5%)
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
0.355KW
|
|
Akan Rasa Load
1.450KW
|
|
Na'urorin haɗi
Daidaitaccen Kanfigareshan
|
1.3 Zane
112.5 KVA kushin da aka ɗora zane da girma.
![]() |
![]() |
02 Masana'antu
2.1 Kori
Cibiya ta ƙunshi ƙafafu a tsaye (ginshiƙai) guda uku, kowace ƙafata tana ɗaukar nau'ikan iskoki guda biyu (maɗaukaki{0}maɗaukakin ƙarfin wutar lantarki da ƙaramar wutar lantarki), daidai da magudanar ruwa guda uku- (phases A, B, and C). Ƙafafunan ƙafa uku suna haɗe da karkiya a kwance, suna kafa hanyar maganadisu rufaffiyar. Tsarin kafa guda uku - yana tabbatar da da'irar maganadisu mai ma'ana, yana rage yuwuwar rashin daidaituwar maganadisu. Tsarin kafa guda uku - yana tabbatar da da'irar maganadisu mai ma'ana, yana rage yuwuwar rashin daidaituwar maganadisu.

2.2 Guda

Babban iska mai ƙarfi{0}waya na iya daidaita adadin juye-juye da tazarar ta hanyar ƙirar ƙira, biyan buƙatun matakan manyan ƙarfin lantarki daban-daban yayin haɓaka aikin rufi da aminci. Ta hanyar yin amfani da dabaru masu ma'ana da rarrabuwa, iskan waya na iya inganta rarraba wutar lantarki yadda ya kamata, hana wuce gona da iri na filayen lantarki wanda zai iya haifar da gazawar rufewa. A cikin iska na waya, ana iya shigar da tashoshi masu sanyaya cikin tsarin don inganta ɓarkewar zafi, tabbatar da tsayin{3}} aiki mai tsayi na iskar wutar lantarki mai girma{4}. Ƙarfin injina na iskar waya ya dogara da kayan jagora da tsarin iska, yana ba da damar ƙirar ƙarfin ƙarfi mai dacewa da juriya na lalacewa kamar yadda ake buƙata.
2.3 Tanko
Tsarin akwatin yayi cikakken la'akari da buƙatun hana ruwa, aminci da sauƙin aiki. Ƙofofin kariya masu tsayi da ƙananan ƙarfin lantarki suna haɗawa da injina, kuma kawai lokacin da aka buɗe ƙofar kariyar ƙarancin matsa lamba, ana iya buɗe ƙofar kariyar matsa lamba don tabbatar da amincin ma'aikatan aiki da kulawa. Akwatin an yi shi da farantin karfe mai inganci na carbon, wanda aka yi ta hanyar mashin daidaitaccen kowane tsari. Bayan tsantsar kula da saman akwatin ciki da na waje, ana amfani da tsarin feshin foda na ci-gaba don maganin foda sau uku, kuma fenti yana da ƙarfi, sawa -mai juriya da ruwa, kuma yana jure wa radiation ultraviolet.

2.4 Taron Karshe

Kundin taro: Shigar da tushe, majalisa, da murfin saman; ware sassa kuma tabbatar da hana ruwa.
Core da Windings: Sanya jigon ƙarfe, haɗa iska, da yin rufi da ɗaurawa.
Tsarin Sanyaya: Sanya radiators, cika mai, kuma cire iska.
Waya: Haɗa manyan tashoshin wutar lantarki{0}} da ƙananan{1}.
Na'urorin kariya: Sanya maɓalli, fis, masu kama walƙiya, da kayan aikin sa ido.
Rufewa da Rufewa: Rufe shingen, shafa maganin lalata, da ƙasa.
03 Gwaji
Gwaje-gwaje na yau da kullun:
- Auna juriya na iska.
- Bincika rabon wutar lantarki mai canzawa da ƙungiyar haɗin kai.
- Auna babu{0}}asara da halin yanzu.
- Auna asarar nauyi da ƙarfin lantarki mai ƙarfi.
Juriya Gwajin Wuta:
- Mitar wutar lantarki ta jure gwajin wutar lantarki (don gwada aikin rufin iska).
- Jarrabawar wuce gona da iri (don duba aikin insulation na windings da ainihin).
Gwaje-gwaje na Musamman(idan an buƙata):
- Gwajin fitarwa na juzu'i (don gano lahanin rufewa).
- Gwajin hawan zafi (don tabbatar da aikin tsarin sanyaya).

04 Shiryawa da jigilar kaya
![]() |
![]() |
05 Yanar Gizo da Takaitawa
A taƙaice, ɗorawa guda uku -saitaccen kushin{1}} na'ura mai ɗaukar nauyi yana haɗe da inganci, amintacce, da aminci cikin ƙaƙƙarfan ƙira mai dorewa. Tare da ci-gaba da rufinta, ingantaccen aikin sanyaya, da ingantaccen fasali na kariya, shine mafita mai kyau don rarraba wutar lantarki na birane, aikace-aikacen masana'antu, da tsarin makamashi mai sabuntawa. Wanda aka keɓance shi don biyan buƙatun abokin ciniki iri-iri, wannan na'urar ta atomatik tana tabbatar da kwanciyar hankali, kulawa kaɗan, da tsawon rayuwar sabis, yana mai da shi amintaccen zaɓi na kayan aikin makamashi na zamani.

Hot Tags: 112.5 kva kushin saka transformer, manufacturer, maroki, farashin, farashi
You Might Also Like
150 kVA Mai Canjin Wuta na Wuta-24.94 / 0.208 kV|Amu...
300 kVA Kushin Dutsen Mai Canjawa-12.47 / 0.48 kV|Am...
1500 kVA Kushin Haɗa Mai Canjawa-34.5 / 0.48 kV|Amur...
750 kVA Kushin Haɓaka Mai Canja wurin Mai amfani-34....
112.5 kVA Matattu Masu Canjin gaba-22.86 / 0.208 kV|...
500 kVA Utility Pad Hawan Canji-24 / 0.48 kV|Amurka ...
Aika Aikace-aikacen