167 kVA Pole Dutsen Rarraba Mai Rarraba-24.94 / 0.12 / 0.24 kV|Kanada 2024

167 kVA Pole Dutsen Rarraba Mai Rarraba-24.94 / 0.12 / 0.24 kV|Kanada 2024

Kasar: Kanada 2025
Yawan aiki: 167 kVA
Wutar lantarki: 24.94GrdY/14.4-0.12/0.24kV
Feature: tare da IFD
Aika Aikace-aikacen

 

 

single pole mounted distribution transformer

Babban Sama, Koyaushe A kunne - Dogon sanda mai Dorewa{0}}Masu Canjin Canji don Ƙarfi mara Katsewa.

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

167 kVA single fase pole mounted transformer an isar da ita zuwa Kanada a shekarar 2025. Ƙarfin wutar lantarkin shine 167 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 24.94GrdY / 14.4 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙarfin lantarki na biyu shine 0.12 / 0.24 kV, kuma sun kafa ƙungiyar vector na Ii6.

Wannan sandar 167kVA da aka ɗora tafsiri mai ƙarfi ne kuma ingantaccen bayani wanda aka tsara don ingantaccen rarraba wutar lantarki a cikin hanyoyin sadarwar lantarki. An sanye shi da mahimman kayan kariya da aiki, yana tabbatar da aminci da kwanciyar hankali a cikin yanayi daban-daban na muhalli. Mahimman abubuwan da aka haɗa sun haɗa da na'urar taimakon matsa lamba don rage ɓangarorin ciki ta hanyar sakin wuce haddi mai yawa, masu goyan bayan masu kamawa don hawan masu kamawa don kariya daga wuce gona da iri, da tsarin Gane Laifin Ciki (IFD) don haɓaka sa ido da gano kuskuren farko.

Bugu da ƙari, na'urar tawul ɗin tana da fasalin kashewa-mai canjin kewayawa, yana ba da damar daidaita ma'aunin wutar lantarki da hannu don ɗaukar buƙatun kaya daban-daban lokacin da aka ƙara kuzari. Karami, mai ɗorewa, da injiniyanci don sauƙin kulawa, wannan rukunin ya dace don amfani da aikace-aikacen masana'antu da ke buƙatar ingantaccen rarraba wutar lantarki.

 

 

 

1.2 Ƙayyadaddun Fasaha

167 kVA iyakacin duniya saka na'ura mai ba da hanya tsakanin hanyoyin sadarwa da takardar bayanai

Isarwa zuwa
Kanada
Shekara
2025
Nau'in
Pole mounted transformer
Daidaitawa
CSA C2.2-06
Ƙarfin Ƙarfi
167 kVA
Yawanci
60HZ
Mataki
1
Polarity
Ƙara
Nau'in Sanyi
ONAN
Babban Voltage
24.94GrdY/14.4kV
Na biyu Voltage
V0.12/0.24 kV
Abubuwan Iska
Aluminum
Matsala ta kusurwa
Ii6
Impedance
3%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
0.295 kW
Akan Rasa Load
2.255 kW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

 

1.3 Zane

167 kVA sandar sandar da aka ɗora zane da girman hoto.

pole mounted distribution transformer diagram pole mounted distribution transformer nameplate

 

 

02 Masana'antu

2.1 Kori

Ana ci gaba da raunata filayen karfen silicon ta hanyar ingantattun injuna zuwa cikin zobe ko gicciye - sashe (misali, rectangular ko kusa da{3}} madauwari) don samar da rufaffiyar da'ira. Bayan iska, ana yin aikin kashe wutar lantarki don sauƙaƙe damuwa na inji da haɓaka kaddarorin maganadisu. Hanyar maganadisu mara kyau tana kawar da ƙarin asarar da ke haifar da rashin daidaituwar juriya na maganadisu a gidajen haɗin gwiwa a cikin laminated. Rufaffiyar da'irar maganadisu tana rage yawan ɗigon ruwa, yana tabbatar da rarraba juzu'in maganadisu iri ɗaya, tare da ingantaccen aikin da ya wuce 99%.

single pole mounted transformer iron core

 

2.2 Guda

single pole mounted transformer wire winding

Tsarin iska na LV foil + HV a cikin sandar sandar da aka ɗora tasfofi yana samun ingantacciyar ma'auni na ingantaccen inganci, aminci, da ƙarancin kulawa. Tsarin lebur yana ƙara yanayin sanyi, yana haɓaka aiki tare da mai ko sanyaya iska. Multi-Layer rufi yana inganta rarraba filin lantarki, yana rage raguwar fitarwa (PD). Gilashin iska yana rage girman nakasar radial; Iskar waya ta HV tana amfani da ingantaccen rufi don wuce gona da iri. Tsarin aluminum yana rage nauyi, manufa don hawan igiya.

 

2.3 Tanko

Kayayyakinmu sun haɗu da rarrabuwa juriya na C4.

1- Tsari Control Enhancement Mun ƙarfafa mu shafi tsari ta gyara surface pretreatment, m tsaftacewa, da kuma sinadaran magani ladabi don kawar da substrate gurbatawa, yayin da tabbatar da garantin shafi kauri bayani dalla-dalla.

{{0}Ingangan Tsarin Tsarin Mun aiwatar da maganin kabu mai hatimi akan duk mahaɗai masu mahimmanci don hana shigar danshi cikin abubuwan ciki na transformer yadda ya kamata.

C4 corrosion resistance oil tank

2.4 Ƙarshe mai dorewa

 

167 kVA single phase pole mounted transformer

An zana tafsirin tafsirin tafsirin daidai gwargwado. An riga an riga an gyara kayan aikin ƙarfe da injina kuma an tsabtace su sosai daga burrs, tsatsa, da gurɓatawa. Patented ruwa ko foda fenti -polyester ko polyurethane{3} an shafa su iri ɗaya, tare da rufe dukkan sassa da haɗa tanki da kewaye don cikakken kariya. Ƙarshen launin toka na ASA 70 ya haɗu da ANSI C57.12.28 kuma ya wuce gwajin feshin gishiri na sa'o'i 1500, ba tare da ƙura ba kuma ba a taɓa shi ba bayan zanen.

 

2.5 Taron Karshe

1. Tawagar iska

Shigar da iskar HV da LV a jere a kan jigon rauni, tabbatar da madaidaicin matsayi na abubuwan da aka gyara na rufi da ɗaure injiniyoyi.

2. Haɗin Wutar Lantarki

Haɗa jagora (tashoshin HV/LV, mai canza famfo) ta hanyar walda ko bolting don kammala da'irar lantarki tsakanin windings, sannan duba juriyar lamba.

3. Core - Bushewar Ruwa

Tsari Bushewar Tanda: Sanya sashin da aka haɗa (core + windings) a cikin tanda mai bushewa don zafi mai zafi{1}}zazzagewar iska ko tururi{2} bushewar lokaci a digiri 105-130 na awanni 48-72 har sai abun cikin damshin rufin ƙasa ko daidai da 0.5%.

4. Shigar Tanki

Canja wurin busasshen sashin aiki da sauri zuwa cikin tanki don hana shayar da danshi, sannan a kiyaye tare da ƙugiya.

5. Na'urorin haɗi

Sanya bushings, bawul ɗin taimako na matsa lamba, IFD, da sauransu.

6. Vacuum Man Cika

Allurar busasshen mai mai hana ruwa a ƙarƙashin injin.

pole mounted distribution transformer assembly

 

03 Ƙungiyoyin Rarraba Masu Canja-canje masu Dutsen Sanyi

HV Bushing LV Bushing
HV Bushing LV Bushing
Copper Strip Arrester Support
Tafiyar Copper Tallafin Kama
IFD Pressure Rellef Device
IFD Na'urar Rellef Matsi
Off-circuit Tap Changer Grounding Terminal
A kashe - Canjin kewayawa Tashar ƙasa

 

04 Gwaji

pole mounted distribution transformer fat
pole mounted transformer factory testing

 

 

05 Kiɗa da jigilar kaya

pole mounted distribution transformer packing
pole mounted distribution transformer shipping

06 site da taƙaitaccen bayani

A matsayin muhimmin sashi a cibiyoyin rarraba wutar lantarki, igiyar wutar lantarki guda ɗaya -iyali{1} da aka ɗora tasfoma tana ba da ƙaƙƙarfan ƙira, sauƙi mai sauƙi, da ingantaccen aiki, yana mai da shi dacewa ga grid na birane da ƙauyuka, wuraren shakatawa na masana'antu, da samar da wutar lantarki. Ƙaddamar da inganci da ƙirƙira, muna ƙoƙari don isar da aminci, inganci, da dorewa mafita ga abokan ciniki a duk duniya. Da fatan za a tuntuɓe mu don ƙarin bayani ko zaɓin sabis na musamman.

167kva pole mounted distribution transformer

 

Hot Tags: sandar sandar ɗora taswira, mai samarwa, mai siyarwa, farashi, farashi

Aika Aikace-aikacen