15 kva pole mounted transformer

Inda ingantacciyar injiniya ta haɗu da ingantaccen aiki -guda ɗaya{1}}ƙaran sandar zamani{2}} ɗora tafsiri.

 

01 Gabaɗaya

1.1 Fagen Aikin

An isar da wutar lantarki guda 15 KVA guda ɗaya na sandar sandar wuta zuwa Kanada a cikin 2024. Ƙarfin da aka ƙididdige ƙarfin wutan lantarki mai ɗorewa shine 15 KVA tare da sanyaya ONAN, ƙarfin farko shine 24.94 KV, ƙarfin lantarki na biyu shine 0.12/0.24 KV. An tsara shi bisa ga daidaitattun CSA C2.2-06.

A kasashen yammacin da suka ci gaba da kudu maso Gabashin Asiya, Arewa da Kudancin Amurka, ana amfani da manyan tafofi guda - a matsayin masu rarrabawa. A cikin hanyar rarraba wutar lantarki da aka rarraba, transfomar lokaci ɗaya{2} azaman na'ura mai rarrabawa yana da fa'idodi masu yawa, yana iya rage tsayin ƙaramin layin rarraba wutar lantarki, rage asarar layi, haɓaka ingancin wutar lantarki. An karɓi ƙira mai girma da ƙarfin ceton coil core, injin taswira yana siffanta yin amfani da dakatarwar da aka ɗora, ƙarami, ƙaramin saka hannun jari, rage ƙananan radius na samar da wutar lantarki, na iya rage asarar layin fiye da 60%. Mai canzawa yana ɗaukar cikakken tsarin da aka rufe, ƙarfin yin nauyi mai ƙarfi, babban aminci a cikin ci gaba da aiki da sauƙi mai sauƙi. Ya dace da tashoshin wutar lantarki na karkara, wuraren tsaunuka masu nisa, ƙauyuka warwatse, samar da noma, hasken wuta da amfani da wutar lantarki, kuma ana iya amfani da shi don makamashi{9}} ceton canjin layukan rarraba ginshiƙai a cikin layin dogo da wutar lantarki na birni.

Mun tabbatar da cewa kowane ɗayan rukunin da aka kawo mu ya yi cikakken gwajin karɓa. Muna ba da sabis na fakiti ɗaya{1} daga tuntuba, ambato, masana'anta, shigarwa, ƙaddamarwa, horarwa zuwa sabis na siyarwa, samfuranmu yanzu suna aiki a fiye da larduna 50 a duniya. Muna nufin zama mafi amintaccen mai samar da ku da kuma mafi kyawun abokin tarayya a cikin kasuwanci!

 

1.2 Ƙayyadaddun Fasaha

15 KVA madaidaicin sandar igiya guda ɗaya da aka ɗora ƙayyadaddun taswira da takaddar bayanai

Isarwa zuwa
Kanada
Shekara
2024
Nau'in
Pole Dutsen Transformer
Daidaitawa
CSA C2.2-06
Ƙarfin Ƙarfi
15 KWA
Yawanci
60HZ
Mataki
1
Polarity
Ƙara
Nau'in Sanyi
ONAN
Liquid insulant
Ma'adinan Mai
Babban Voltage
24.94KV
Na biyu Voltage
0.12/0.24KV
Abubuwan Iska
Aluminum
Impedance
1.5%
Matsa Canji
OLTC
Taɓa Range
±2*2.5%
Na'urorin haɗi
Daidaitaccen Kanfigareshan
Jawabi
N/A

 

1.3 Zane

15 KVA sandar sandar da aka ɗora zane da girma.

15 kva pole mounted transformer diagram

15 kva pole mounted transformer nameplate

 

 

02 Masana'antu

2.1 Kori

Iron core rungumi dabi'ar lebur bude lankwasawa nada core tsari, wanda yana da mafi ingancin electromagnetic yi, karamin zumudi na halin yanzu, low no{0}}asara kaya, low amo, karamin size, haske nauyi, muhalli kariya da makamashi ceto, m core samar, high quality inganci, kananan bayyanar size da sauran abũbuwan amfãni, na iya saduwa da bukatun abokan ciniki kowane girman.

15 kva pole mounted transformer core

 

2.2 Guda

foil winding transformer

Foil winding transformer sabon nau'in tasfomar busassun ce idan aka kwatanta da na gargajiya, kuma ƙarancinsa - ƙarfin wutar lantarki ba ya rauni ta hanyar jujjuyawar waya ta jan karfe, amma an naɗe shi da faɗin takardan foil na aluminum kusa da tsayin sama da ƙasa. The foil winding transformer yana da fa'idodi da yawa, kamar nauyi mai sauƙi, ƙarancin abu, gajeriyar gajeriyar juriyar kewayawa da ingantaccen samarwa da yawa.

 

2.3 Tanko

Kamfaninmu yana amfani da ƙaramin ƙarfe mai inganci{0}a matsayin ɗanyen kayan aikin samar da tankunan mai, kuma yana amfani da injina na ruwa ko wasu kayan aiki don lanƙwasa, yanke da danna farantin karfen zuwa siffar da ake so na tankin mai. Butt da aka gyara da kuma yi gas garkuwa waldi ko wasu waldi matakai don tabbatar da tightness da tsarin ƙarfi na tanki. An rufe dukkan hatimi a ƙarshen iyaka; An zagaye sassan ƙarfe a ciki da wajen akwatin don cire gashi, kuma ana gwada suturar weld da hatimi har sau uku (hasken haske, matsi mai kyau, gwajin yabo mara kyau); Ana yin fenti bisa ga daidaitattun buƙatun hana tsatsa-.

high-quality stainless steel tank

 

2.4 Taron Karshe

high-quality stainless steel final assembly

Hanyar tarawa na lokaci ɗaya - otal ɗin da aka ɗora wutar lantarki

1. Shigar da baƙin ƙarfe a kan wurin zama na ƙarfe. Ya kamata a lura cewa kada a sami kusurwoyi masu kaifi a kan wurin zama don kauce wa yanke kayan rufewa.

2. Shigar da kayan rufewa a kan tushen ƙarfe. Ayyukan kayan rufewa shine keɓance coil ɗin shigarwa daga coil ɗin fitarwa kuma ya hana gajerun kewayawa tsakanin iska.

3. Kunna coil a kusa da kayan rufewa. Kula da layin iska, wanda ya kamata a aiwatar da shi bisa ga buƙatun ƙira. Har ila yau, wajibi ne a kula da ko iskar coil din daidai ne, in ba haka ba zai shafi tasirin aikin na'urar.

4. Haɗa allon tashar. Tashar jirgin zai iya zama madaidaicin waya ko tasha. Zaɓi tashar tasha bisa ga ainihin halin da ake ciki. Bugu da ƙari, wajibi ne a kula da girman ma'aunin waya ko tashoshi, don dacewa da nada.

5. Haɗa nada zuwa allon tashar. Lokacin haɗa coils da allunan tasha, yi amfani da kayan rufewa da suka dace don tabbatar da ingantaccen haɗin gwiwa da kwanciyar hankali.

6. Haɗa harsashi. Babban aikin gidan shine don kare coil da kuma ware shigarwar da fitarwa cikin aminci. Lokacin haɗuwa, ya zama dole a kula da girman da kayan harsashi, da kuma la'akari da bukatun zafi da kariya.

 

 

03 Gwaji

Masu tasfofi guda ɗaya{0}}yawanci ana buƙatar yin gwajin gwaji masu zuwa:

Gwajin insulation: gami da gwajin juriya, gwajin hasarar dielectric da gwajin fitarwa na yanki don tabbatar da amincin tsarin rufin.

Gwajin wutar lantarki: Aiwatar da takamaiman irin ƙarfin lantarki tsakanin babban ƙarfin wutar lantarki da ƙaramin wutar lantarki don gwada ko insulation na na'urar zata iya jure babban ƙarfin lantarki.

Gwajin juriya: Gwada juriya na iska da tsarin ƙasa don tabbatar da cewa ya cika buƙatun ƙira.

A'a{0}}gwajin lodi: Gwada aikin wutar lantarki na taransfoma a ƙarƙashin babu-sharadi, gami da babu{2}}asara da babu{3}}load current.

Gwajin lodi: gwada aikin taransfoma a ƙarƙashin ƙimar ƙima don tabbatar da cewa yana iya aiki da ƙarfi da aminci.

Gwajin tashin zafin jiki: ƙarƙashin yanayin kaya mai ƙima, gwada haɓakar zafin na'urar don tabbatar da cewa ba zai lalace ta hanyar zafi ba.

Gwajin wuce gona da iri: Gwada karfin jujjuyawar na'urar don tabbatar da cewa ba za ta lalace ba idan ya wuce kima na wucin gadi.

Gwajin gajeriyar kewayawa: Gwada ƙarfin gajeriyar da'ira na taransfoma don tabbatar da cewa ba zai lalace ba a yanayin gajeriyar da'ira.

 

15 kva pole mounted transformer test
pole mounted transformer routine test

 

 

04 Shiryawa da jigilar kaya

packing of transformer
container transportation of transformer
 

 

05 Yanar Gizo da Takaitawa

Mun gode don sha'awar ku ga tiransifoma mai hawa guda ɗaya{0}}asashe{1}! Tare da fa'idodinsa na ingantaccen inganci, dogaro, da ceton kuzari, ana amfani da wannan samfurin a cikin tsarin rarraba wutar lantarki, yana biyan buƙatun wutar lantarki a yanayi daban-daban. Mun himmatu wajen samar da samfurori da ayyuka masu inganci don tabbatar da aminci da kwanciyar hankali na tsarin wutar lantarki. Muna fatan yin aiki tare da ku don ciyar da ci gaban masana'antar wutar lantarki tare!

container transportation advantages

 

Hot Tags: 15 kva iyakacin duniya saka transformer, manufacturer, maroki, farashin, farashi

Aika Aikace-aikacen