75 kVA Transformer Akan Layin Wuta-12.4 * 24.94 / 0.12 * 0.24 kV|Saudi Arabia 2023

75 kVA Transformer Akan Layin Wuta-12.4 * 24.94 / 0.12 * 0.24 kV|Saudi Arabia 2023

Kasar: Saudi Arabia 2024
Yawan aiki: 75kVA
Wutar lantarki: 12.4/24.94-0.24kV
Siffar: tare da na'urar hanawa
Aika Aikace-aikacen

 

 

75 kVA transformer on power lines

Simplifying Power Delivery: Single Phase Pole-Mounted Transformers for Reliable Energy Solutions!

 

01 Gabaɗaya

1.1 Fagen Aikin

Wannan 75kVA guda fase sandal da aka saka taransfoma an isar da ita zuwa Saudi Arabiya a shekarar 2024. Ƙarfin wutar lantarki na na'urar shine 75kVA. high ƙarfin lantarki ne dual high ƙarfin lantarki. Ƙarin jujjuyawar wutan lantarki guda biyu fiye da na'urar wutan lantarki guda ɗaya na gama gari.

Pole{0}}wayoyin wuta da aka ɗora suna da mahimmanci don ingantaccen rarraba wutar lantarki, an ƙera su don rage tazarar ƙananan layukan wutar lantarki da rage asarar kuzari sosai. Ƙirarsu mai ƙanƙantar nauyi da nauyi tana ba da damar shigarwa cikin sauri akan sandunan amfani, rage farashin kayayyakin more rayuwa- musamman masu fa'ida a yankunan karkara da wuraren da ba a kula da su ba.

Tare da ci-gaba da fasahar coil core, waɗannan taswira sun sami raguwa sama da 60% na asarar layi, haɓaka amincin wutar lantarki. Gine-ginen su cikakke yana ba da kariya daga abubuwan muhalli, yana tabbatar da dorewa da aiki mai aminci yayin lodi.

Ire-iren aikace-aikacen aikace-aikacen, sandar sandar sandar{0}masu tafsiri suna ba da kayan aikin gona, ƙauyuka masu nisa, da haɓaka abubuwan more rayuwa na birni. Ƙarƙashin bukatun su na kulawa da babban abin dogaro ya sa su zama zaɓi mai kyau don haɓaka tsarin rarraba wutar lantarki, samar da wutar lantarki ga al'ummomi daban-daban.

 

 

1.2 Ƙayyadaddun Fasaha

75kVA guda lokaci mai canzawa ƙayyadaddun bayanai da takaddun bayanai

Isarwa zuwa
Saudi Arabia
Shekara
2024
Samfura
12.4GRDY/7.2*24.94GRDY/14.4-0.24/0.12kV
Nau'in
Juzu'i guda sandar sandar da aka saka taransifoma
Daidaitawa
IEEE C57.12.00
Ƙarfin Ƙarfi
75kv ku
Yawanci
60HZ
Mataki
Single
Nau'in Sanyi
ONAN
Babban Voltage
12.4GRDY/7.2*24.94GRDY/14.4kV
Na biyu Voltage
0.24/0.12kV
Abubuwan Iska
Aluminum
Polarity
Ragewa
Impedance
2%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
0.155KW
Akan Rasa Load
0.67KW
Na'urorin haɗi
Daidaitaccen Kanfigareshan
Jawabi
N/A

 

1.3 Zane

75kVA lokaci guda sandar sandar sandar da aka ɗora ma'aunin wuta da cikakkun bayanai masu nauyi

75 kVA transformer on power lines diagram 75 kVA transformer on power lines nameplate

 

 

02 Masana'antu

2.1 Kori

Iron core yana daya daga cikin mahimman abubuwan da ake amfani da su a cikin taswirar, wanda shine sashin da'ira na maganadisu na injin. Na farko da na biyu windings na transformer suna kan baƙin ƙarfe core. Domin inganta ƙarfin maganadisu na da'irar maganadisu da kuma rage hasarar eddy a halin yanzu a cikin ɗigon baƙin ƙarfe, ƙarfen ƙarfe an yi shi da takardar ƙarfe na silicon tare da rufin saman. Ƙarfin core ya kasu kashi biyu: ginshiƙin ƙarfe na ƙarfe da karkiya na ƙarfe. An saita iskar gas ɗin akan jigon ƙarfe, kuma karkiya ta ƙarfe tana haɗa ɗigon ƙarfe don samar da rufaffiyar da'irar maganadisu.

Domin hana fitarwa da ke haifar da yuwuwar yuwuwar dakatarwa na abubuwan ƙarfe kamar su transformer core, manne da zoben matsa lamba yayin aiki, waɗannan abubuwan dole ne a yi ƙasa a wuri guda. Don sauƙaƙe gwaji da gano kuskure, manyan tasfotoci gabaɗaya suna niƙa ƙarfe kuma suna manne ta cikin daji biyu bi da bi.

75 kVA transformer on power lines wound iron core

 

2.2 Guda

75 kVA transformer on power lines winding

Tsarin jujjuyawar taswira yana ɗaukar iska mai iska, wanda a cikinsa aka raba coils ɗin naɗa zuwa yadudduka da yawa kuma a madadinsa akan tushen ƙarfe. Wannan ƙira yana taimakawa rage ƙarfin ƙarfin wutan lantarki na nada kuma yana ƙara aikin rufewar na'urar.

Musamman, halayen iska na Layer sun haɗa da:

Girke-girke na iska: Layer winding shine iskar coils ɗin da aka jera akan tushen ƙarfe don rage haɓakar induction na lantarki, rage ƙarfin wutar lantarki a cikin iska, da haɓaka ƙarfin rufewa.

Rage shigar da yatsan maganadisu: Saboda giciye tsakanin coils na iska, iska mai iska na iya rage shigar da ɗigowar maganadisu yadda ya kamata da haɓaka ingancin watsa wutar lantarki.

Rage asara na yanzu: Saboda tsarin tattarawar na'urorin da aka tattara, za a iya rage asarar da ake yi a yanzu kuma ana iya inganta ingancin na'urar.

 

2.3 Tanko

Za'a iya inganta ƙirar tanki dangane da farashi da nauyi, rage yawan jigilar jigilar kayayyaki da nauyi.

Ana iya rage matakan girgizar da ke kan tankunan tanki sosai, yana ba da ƙarin aminci a cikin sabis.

Ƙirar tanki mai tsauri yana watsa ƙarancin hayaniyar cikin gida da ainihin ke haifarwa (babban tushen amo{0}}ƙara) da iska (babban tushen hayaniyar lodi) zuwa waje, yana haifar da na'ura mai natsuwa a cikin sabis. Wannan yana da mahimmanci musamman idan aka yi la'akari da tsauraran matakan kula da muhalli a yanzu don gurbatar hayaniya.

Electrostatic fesa magani, shekaru 50 ba cire fenti (shafi juriya lalata a cikin 100h, taurin Mafi girma ko daidai da 0.4)

Nau'in Silinda cikakken ginin da aka rufe tare da kai{0}}madaidaicin bawul ɗin taimakon matsa lamba (ANSI ƙayyadaddun bayanai)

Daidaitaccen madaidaicin madaidaicin madaidaicin NEMA (kowace rukunin ya haɗa da faranti na goyan bayan sanda)

Tsarin da aka rufe cikakke, kulawa{0}} kyauta, rayuwar aiki ta yau da kullun fiye da shekaru 30

75 kVA transformer on power lines oil tank

 

2.4 Taron Karshe

75 kVA transformer on power lines assembly

Babban Taro: Haɗa ainihin abubuwan haɗin gwiwa tare.

Shigar da iska: Iskar coils na farko da na sakandare bisa ga ma'auni kuma aiwatar da jiyya.

Majalisar Tsarin Tsarin Insulation: Shigar da kayan rufewa don tabbatar da aminci a ƙarƙashin babban ƙarfin lantarki.

Kundin taro: Haɗa shingen kariya don hana tasirin muhalli.

Haɗin Kebul: Haɗa kebul ɗin ke kaiwa don tabbatar da ingantaccen dubawa.

 

 

03 Gwaji

A'a.

Gwajin Abun

Naúrar

Karba

Darajoji

Ƙimar Ma'auni

Kammalawa

1

Ma'aunin Juriya

/

/

/

Wuce

2

Gwajin Rabo

/

Bambancin rabon ƙarfin lantarki akan babban tapping: ƙasa da ko daidai da 0.5%

Alamar haɗi: Ii0

-0.03/-0.03

Wuce

3

Gwajin polarity

/

Ragewa

Ragewa

Wuce

4

A'a -asara da tashin hankali na halin yanzu

%

kW

I0:: bayar da ma'auni darajar

P0: ba da ƙima mai ƙima

Hakuri don babu asarar kaya shine +10%

0.19

0.142

Wuce

5

Load asarar, impedance ƙarfin lantarki, jimlar asarar da kuma yadda ya dace

/

kW

kW

t:85 ku

Z%: ƙimar da aka auna

Pk: ƙimar ƙima

Pt: ƙima mai ƙima

Haƙuri don impedance shine ± 15%

Haƙuri don jimlar asarar kaya shine +6%

2.27

0.726

0.868

99.19

Wuce

合格

6

Gwajin Karfin Wutar Lantarki

/

LV: 10kV 60s

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

7

Jarrabawar Juriya da Wutar Lantarki

/

Wutar lantarki mai aiki (KV): 40

Duration(s): 48

Mitar (HZ): 150

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

8

Ma'aunin Resistance Insulation

LV -HV zuwa Ground

10.2

/

9

Gwajin Leaka

/

matsa lamba: 20kPA

Tsawon lokaci: 12h

Babu yabo kuma babu

Lalacewa

Wuce

10

Gwajin Dielectric Oil

kV

Yafi ko daidai da 45

54.96

Wuce

 

75 kVA transformer on power lines test
75 kVA transformer on power lines testing

 

 

04 Shiryawa da jigilar kaya

4.1 Shiryawa

Rufewa: Transformer an lullube shi da kayan rufe fuska da firgita -kayan sha, irin su kumfa mai kumfa da kumfa, don hana lalacewa yayin sarrafawa da wucewa.

Dambe: Sanya na'ura mai canzawa a cikin akwatin katako mai ƙarfi wanda aka ƙera don tsayayya da tasiri da mugun aiki, yana ba da ƙarin kariya.

Tabbatarwa: A cikin akwatin katako, injin tawul ɗin yana kiyaye shi da madauri ko takalmin gyaran kafa don hana shi motsi da kuma hana motsi yayin sufuri.

Rufewa da Lakabi: Akwatin katako an kulle kuma an yi masa lakabi tare da umarnin kulawa da alamun gargaɗi don nuna rashin ƙarfi na abubuwan ciki.

75 kVA transformer on power lines packing

 

4.2 Shipping

75 kVA transformer on power lines shipping

Ana lodawa: A hankali loda na'urar taransifoma a kan babbar mota mai kwance ko tirela ta musamman, tana tabbatar da daidaito.

Tabbatarwa: Kare tafsirin da madauri ko sarƙoƙi don hana motsi.

Tsarin Hanya: Shirya mafi kyawun hanyar sufuri, la'akari da yanayin hanya da iyakokin nauyi.

Kula da Kariya: Yi hankali a hankali yayin lodawa da saukewa don guje wa tasiri ko karaya.

Isowa da saukewa: Bayan isowa, sai a sauke kaya kuma a sanya taransfoma a wurin da aka keɓe.

 

 

05 Yanar Gizo da Takaitawa

A cikin mahallin canjin makamashi da ci gaba mai dorewa, igiyar wutar lantarki guda ɗaya -iyali{1} da aka ɗora ta zama na'ura mai mahimmanci a tsarin wutar lantarki na zamani saboda ingantaccen ƙarfin watsa wutar lantarki. Yana inganta ingantaccen amfani da makamashi kuma yana rage amfani da makamashi yayin da yake tabbatar da aiki mai aminci a wurare daban-daban. Tare da kyakkyawan juriya da yawa, yana tallafawa gina kayan aikin wutar lantarki. Ta hanyar rage asarar makamashi da amfani da kayan inganci masu inganci, wannan tafsiri yana nuna yuwuwar aikace-aikace, yana haɓaka ci gaba mai dorewa. Zaɓin samfuranmu yana nufin zaɓin ingantaccen muhalli da ingantaccen maganin wutar lantarki, yayin da muke aiki tare don ƙirƙirar kyakkyawar makoma.

75 kVA pole transformer on power lines

 

Hot Tags: transformer akan layukan wuta,manufacturer,maroki,farashi,farashi

Aika Aikace-aikacen