4390 KVA Transformer Pad Dutsen-24 / 0.69 KV|Jamaica 2025

4390 KVA Transformer Pad Dutsen-24 / 0.69 KV|Jamaica 2025

Kasar: Jamaica 2025
Yawan aiki: 4390 kVA
Wutar lantarki: 23.9GrdY/13.8-0.69D kV
Feature: tare da garkuwar ƙasa
Aika Aikace-aikacen

 

transformer pad mount

Injiniya don karɓuwa, ƙira don yin aiki{0}} na'urorin da aka ɗora tafsirin su ke jagorantar hanya.

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

4390 kVAuku fase kushin saka transformeran kai Jamaica a 2025. The rated power oftaswirar kushin hawashine 4390 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 23.9GrdY / 13.8 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.69D kV, sun kafa ƙungiyar vector na YNd1.

An ƙirƙira shi don amintaccen rarraba wutar lantarki a waje a cikin kasuwanci, masana'antu, da aikace-aikacen kayan more rayuwa, wannan 50Hz uku{1}mataki na uku{2}} ɗorawa na wutan lantarki yana haɗa kayan ci-gaba, ingantaccen aikin lantarki, da juriya mai ƙarfi{3}}wanda aka gina shi da bakin karfe 304 don karɓuwa da ajin juriya na C5M, wanda aka cika shi da farin foda{0} wanda ke kiyaye mutuncin kyawawa da haɓaka kariyar yanayi{8} yayin da yake nuna FR3 dielectric ruwa don ingantaccen amincin wuta, dacewa da muhalli, da kwanciyar hankali na zafi, tare da keɓewar garkuwar ƙasa da keɓance hannun rigar ƙasa don murkushe tsangwama na lantarki, rage haɗarin fitarwa na ɗan lokaci, da tabbatar da abin dogaro. Ƙarfafa ƙimar inganci mai girma na 99.2% don rage asarar makamashi da ƙarancin 7.5% gajere - kewayawar kewayawa don ingantaccen iyakantaccen kuskure na yanzu, yana ba da ingantaccen ƙarfin aiki a cikin bambance-bambancen zafin jiki (4330kVA a digiri 45 da 4075kVA a digiri na 50), haɗaɗɗen ayyuka masu ƙarfi da haɓaka aiki mai ƙarfi. yanayi daban-daban da yanayin muhalli.

 

 

 

1.2 Ƙayyadaddun Fasaha

4390 kVA taswirar kushin Dutsen ƙayyadaddun bayanai da takardar bayanai

Isarwa zuwa
Jamaica
Shekara
2025
Nau'in
Tashin wutar lantarki
Daidaitawa
Saukewa: IEC60076
Ƙarfin Ƙarfi
4390 kVA
Yawanci
50HZ
Mataki
3
Ciyarwa
Madauki
Gaba
Matattu
Nau'in Sanyi
KNAN
Babban Voltage
23.9GrdY/13.8kV
Na biyu Voltage
0.63 kV
Abubuwan Iska
Copper
Ƙungiyar Vector
YNd1
Impedance
7.5%
inganci
99.2%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
3.95 kW
Akan Rasa Load
28 kW

 

1.3 Zane

4390 kVA mai canzawa pad Dutsen zane da girman zane.

transformer pad mount diagram transformer pad mount nameplate

 

 

02 Masana'antu

2.1 Kori

transformer pad mount three-limb core

Ƙaƙƙarfan ƙira mai ƙarfi guda uku{0}} yana tabbatar da dorewar dogon lokaci{1} ƙarƙashin sharuɗɗan buƙata. Ta hanyar rage lalacewar aiki, yana kare hannun jarin ku kuma yana rage haɗarin raguwar lokaci mai tsada, yana ba da tabbacin ingantaccen wutar lantarki na shekaru masu zuwa.

 

2.2 Guda

Gina tare da 100% jan karfe - HV foil don ingantaccen kwanciyar hankali, waya ta LV don ingantaccen aiki. Wannan ginin yana jure yanayin zafin zafi da yanayin kuskure, yana rage haɗarin gazawa sosai da kuma kare hannun jarin ku daga raguwa mai tsada.

transformer pad mount copper winding

 

2.3 Tanko

transformer pad mount tank with 304 stainless steel and C5M anti-corrosion grade

Gina tare da bakin karfe 304 da C5M anti{2}}lalacewa, tankin mu ya wuce na'urorin ƙarfe na carbon na al'ada. Kulawa{4}}}arashen farin kyauta yana ba da garantin 30+ shekaru na ingantaccen sabis, yana kare jarin ku inda wasu ba za su gaza ba.

 

2.4 Taron Karshe

Daidai haɗuwa kuma an gwada shi sosai, kowane tafsiri yana haɗa ingantattun abubuwan haɗin gwiwa zuwa cikin shirye-shiryen -don{1}}aiki. Wannan yana tabbatar da gaggawa, matsala{3}}aiki kyauta daga rana ɗaya, yana kawar da hatsarori da kuma isar da dogaro mai tsawo{4}}.

transformer pad mount precisely assembled and rigorously tested

 

 

03 Gwaji

An ƙirƙira don biyan buƙatun ku na dogaro da farashi{0}} inganci, injin mu guda uku{1} da aka ɗora wutar lantarki yana fuskantar gwaji mai ƙarfi wanda ya wuce ainihin buƙatu. Yin biyayya da ƙa'idodin IEC na ƙasa da ƙasa, gwaje-gwajen maɓalli sun haɗa da jurewar ƙarfin lantarki na 150Hz (40s), ma'aunin juriya na madaidaici, da ƙaƙƙarfan gwajin ɗigon ruwa (babu ɗigo/ nakasa). Mahimman bayanai kamar karkatar da rabon wutar lantarki (-0.03%~-0.01%, da kyau tsakanin ±0.5%), matsananci{12}}ƙananan babu{15}} load halin yanzu (0.22%), da tsayayye na ɗan gajeren lokaci (7.12%) yana tabbatar da kyakkyawan aikinsa. Muna tabbatar da samfurin mu ba kawai ya dace ba amma ya wuce tsammaninku don kwanciyar hankali, aminci, da ƙimar dogon lokaci.

A'a.

Gwajin Abun

Naúrar

Karba

Darajoji

Ƙimar Ma'auni

Kammalawa

1

Ma'aunin Juriya

%

Matsakaicin juriya rashin daidaituwa

3.82

Wuce

2

Gwajin Rabo

%

Bambancin rabon ƙarfin lantarki akan babban tapping: ƙasa da ko daidai da 0.5%

Alamar haɗi: YNd1

-0.03% ~- 0.01%

Wuce

3

zango{0}}gwajin dangantaka

/

YNd1

YNd1

Wuce

4

A'a -asara da tashin hankali na halin yanzu

/

I0 :: bayar da ma'auni darajar

0.22%

Wuce

P0: ba da ƙima mai ƙima

3.429 kW

juriyar rashin hasara shine +15%

/

5

Load hasarar impedance ƙarfin lantarki da inganci

/

t: 75

haƙuri ga impedance shine ± 10%

juriyar jimlar asarar kaya shine +10%

/

Wuce

Z%: ƙimar da aka auna

7.12%

Pk: ƙimar ƙima

27.924 kW

Pt: ƙima mai ƙima

31.353 kW

Ingancin ba kasa da 99.2%

99.29%

 

6

Gwajin Karfin Wutar Lantarki

kV

LV: 10kV 60s

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

7

Jarrabawar Juriya da Wutar Lantarki

kV

Wutar lantarki mai aiki (KV):2Ur

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

Duration(s):40

Mitar (HZ): 150

8

Gwajin Leaka

kPa

matsa lamba: 50kPA

Babu yabo kuma babu

Lalacewa

Wuce

Tsawon lokaci: 24h

9

Ma'aunin Resistance Insulation

HV{0}LV zuwa Ground

1.92

/

LV -HV zuwa Ground

1.31

HV&LV zuwa Ground

0.902

 

transformer pad mount test
transformer pad mount strict test

 

 

04 Shiryawa da jigilar kaya

4.1 Shiryawa

transformer pad mount wooden box package

Alƙawarinmu na inganci ya kai har zuwa bayarwa. ƙwararrun marufi na katako ba wai kawai yana kiyaye mahimman kadarar ku daga ƙwaƙƙwaran dabaru ba amma kuma yana nuna cikakkiyar kulawar mu ga daki-daki. Yana ba da garantin ba da samfur mara aibi zuwa gare ku, yana tabbatar da fara aikin mai santsi da inganci.

 

4.2 Shipping

Amintaccen isar da wutar lantarki ta DDU zuwa Filin jirgin saman Norman Manley shine sadaukarwar mu. Muna ba da garantin amincin sa tare da ƙaƙƙarfan ƙaƙƙarfan ƙaƙƙarfan ƙaƙƙarfan katako na al'ada{1} da kuma ƙaƙƙarfan bin ƙa'idodin sufuri na ƙasa da ƙasa don kayan aikin lantarki masu ƙima. Ƙwarewarmu ta ƙware wajen sarrafa hadaddun dabaru zuwa wurare kamar KIN, gami da share ƙa'idodin kwastam na farko, yana kawar da rashin tabbas ɗin aikinku kuma yana kiyaye tsarin lokacin aikin ku, yana tabbatar da haɗari{5}} mika kyauta a wurin da aka yarda.

transformer pad mount with DDU delivery

 

 

05 Yanar Gizo da Takaitawa

Yayin da kuke tsara mahimman abubuwan more rayuwa waɗanda ke ba da iko ga al'ummarku ko kasuwancinku, shawarar ta wuce sayayya mai sauƙi. Saka hannun jari ne a cikin shekarun da suka gabata na ingantaccen aiki. Ta hanyar zabar dutsen kushin mu na canji, ba kawai kuna samun ingantaccen samfuri tare da ingantaccen inganci da rayuwar ƙira mai tsayi ba; kana samun abokin tarayya mai kwazo.Sawun masana'antunmu na duniya da tallafin fasaha na gidatabbatar da cewa muna tare da ku daga shigarwa maras kyau a duk tsawon rayuwa, rage girman kuɗin mallakar ku. Yi amintacce, zaɓi na dogon lokaci{1}. Haɗin gwiwa tare da mu don gina ingantaccen ƙarfi da ingantaccen makamashi nan gaba.