300 KVA Matattu Masu Canjin gaba-12.47 / 0.208 KV|Kanada 2024

300 KVA Matattu Masu Canjin gaba-12.47 / 0.208 KV|Kanada 2024

Ƙasar Bayarwa: Kanada 2024
Yawan aiki: 300kVA
Wutar lantarki: 12.47Grdy/7.2 X 4.16Grdy/2.4-0.208y/0.12 kV
Feature: Tare da IFD
Aika Aikace-aikacen

 

300 kva dead front transformers-inside-view

SCOTECH's 300 kVA matattu - na'urorin wuta na gaba suna ba da ingantaccen, CSA{2}} ikon da ya dace ga Kanada.

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

A cikin 2024, wani abokin ciniki na Kanada ya ba da oda ga matattu na gaba na KVA 300 da aka ƙera kuma an ƙera su cikin cikakkiyar yarda da CSA Standard C227.4:21. An gina waɗannan na'urorin wuta don ingantaccen aiki a waje, madauki{4}} tsarin rarraba ciyarwa tare da hanyoyin sadarwa masu inganci.

An kawo 300 kVA guda uku -kushin lokaci{2}} wanda aka ɗora a matsayin wani ɓangare na wannan aikin. Yana da mataccen ƙira ta gaba wanda ke tabbatar da aminci da sauƙin aiki. Hanyar kwantar da hankali ita ce ONAN, tana ba da ingantaccen yanayin zafi a ƙarƙashin duk yanayin kaya. Mai canzawa yana amfani da ma'adinai mai ma'adinai da iska na aluminum, yana ba da ma'auni mai kyau tsakanin babban inganci da farashi. An ƙididdige shi a 300 kVA, 60 Hz, tare da babban ƙarfin lantarki na 12.47/4.16 kV da ƙarfin lantarki na biyu na 0.208 kV.

Haɗin iska shine YNyn0, dacewa da hanyoyin sadarwar rarraba ƙasa. Babu -mai canza matsi (NLTC) tare da kewayon bugun ± 2×2.5%. Wannan yana ba da damar daidaita wutar lantarki mai dacewa don dacewa da yanayin aiki daban-daban kuma tabbatar da ingantaccen tsarin aiki. Transformer yana samun inganci 98.94%, ba tare da -asarar kaya ƙasa da ko daidai da 800 W da asarar kaya ƙasa da ko daidai da 3580 W. Yana da daidaitattun na'urorin haɗi na CSA{12}} na'urorin haɗi masu dacewa da ƙirar ƙafa 5 don ingantaccen aiki a ƙarƙashin haɗin Y–Y mai tushe.

Wannan isarwa tana nunawaSCOTECH ta sadaukar da kai don isar da inganci mai inganci{{0}, CSA - ƙwararrun tafofi da aka keɓance don kasuwar rarraba wutar lantarki ta Kanada.

 

 

 

1.2 Ƙayyadaddun Fasaha

300 KVA matattu na gaba tafsiri da takaddun bayanai

Isarwa zuwa
Kanada
Shekara
2024
Nau'in
Uku fanni kushin Dutsen transformer
Daidaitawa
CSA C227.4:21
Ƙarfin Ƙarfi
300 KVA
Yawanci
60HZ
Ciyarwa
Radial
Gaba
Matattu
Mataki
uku
Nau'in Sanyi
ONAN
Liquid insulant
Ma'adinan Mai
Babban Voltage
12.47 (4.16) kV
Na biyu Voltage
0.208 kV
Ƙungiyar Vector
YNyn0
Abubuwan Iska
Aluminum
Impedance
4 %
inganci
98.94%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
Kasa da ko daidai da 800 W
Akan Rasa Load
Kasa da ko daidai da 3580 W
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

300 KVA matattu tasfotocin gaba da zane da farantin suna

300 KVA Dead Front Transformers drawing 300 KVA Dead Front Transformers nameplate

 

 

02 Masana'antu

2.1 Alamar Matsayin Mai

300 kVA dead front transformers Oil Level Indicator

Alamar matakin mai yana ba ku damar ganin mataccen mai na gaba na KVA 300 a kallo, a ainihin lokacin, don ku san ko inda ya kamata ya kasance. Man ba kawai rufin asiri ba ne kawai yana ɗaukar zafi daga iska da kuma ainihin ma. Idan matakin ya faɗi, yana iya zama ɗigo, ko kuma wani abu a ciki na iya yin kuskure. Tare da alamun gani ko na'urori masu auna firikwensin, masu aiki zasu iya yin sama ko duba da sauri, suna taimakawa hana gazawa da tsawaita rayuwa. Yawancin lokaci ana shigar da shi inda yake da sauƙin dubawa, yana sa binciken yau da kullun ya fi aminci da sauƙi.

 

2.2 IFD & Drain Valve

Internal Fault Detector, IFD, da magudanar ruwa kowanne yana da rawar da ya taka, amma tare suna kiyaye taransfoma lafiya. IFD tana jin iskar gas da ba a saba gani ba ko ƙananan sigina na baka, gargadi game da iska ko al'amuran rufewa da wuri. Magudanar ruwa yana ba ka damar cire mai, don kulawa akai-akai ko gaggawa. Tare da duka biyun, zaku iya fuskantar haɗari da wuri kuma ku sarrafa mai lafiya. Musamman a cikin na'urori masu canzawa- uku, faɗakarwa akan lokaci da sarrafa man mai suna taimakawa wajen kiyaye komai da kuma guje wa manyan matsaloli a kan layi.

300 kVA dead front transformers IFD Drain Valve

 

 

2.3 Bawul ɗin Taimakon Matsi & Ma'aunin Matsala

300 kVA dead front transformers Pressure Relief Valve Vacuum Pressure Gauge

A cikin gidan wuta, bawul ɗin taimako na matsa lamba da ma'aunin matsa lamba suna aiki kamar ƙaramin ƙungiyar aminci. Bawul ɗin taimako - yana buɗewa lokacin da iskar gas ya hau sama da yawa; yana kare tanki, hatimi. Ma'aunin Vacuum -yana nuna jujjuyawar matsa lamba, alamun canjin yanayin zafi, faɗaɗa mai, ƙila matsalolin rufewa. Tare, saurin kallo yana ba masu aiki cikakken hoto. Spot overpression, mummunan matsa lamba da wuri; yana taimakawa ceton rufi, sassa na inji. Musamman mahimmanci a cikin tasfofi na zamani guda uku{7}, inda laifi ɗaya zai iya ruguza dukkan naúrar.

 

2.4 Thermometer

Ma'aunin zafi da sanyio na bin diddigin mai da yanayin zafi, yana nuna yadda zafin na'urar ke gudana. Babban zafi yana tsufar mai da sauri, yana damuwa da rufi, kuma yana iya wuce gona da iri. Kallon karatun yana taimaka wa masu aiki su yanke shawarar ko za su rage kaya, ba da iska mai yawa, ko shirin kiyayewa. Ana iya bincika bayanin da hannu ko ciyar da shi cikin tsarin sa ido. Na kashi uku -, yana da mahimmanci don ganin yanayin zafin kowane lokaci, daidaita al'amura, guje wa abubuwan mamaki, da tabbatar da cewa wutar tana ci gaba da gudana a hankali.

300 kVA dead front transformers Thermometer

 

03 Gwaji

Matsayin Gwaji  

Saukewa: CSA227.4-21

Uku -,kushin - masu rarraba tafsiritare da keɓaɓɓen rufi

manyan masu haɗa wutar lantarki{{0}

CSA{0}C802.1-13 (R2022)

Ƙimar Ƙarfin Ƙarfi don Liquid{0}}Cikakken Masu Canza Rarraba

 

Gwajin yau da kullun

1 Ma'aunin Juriya
2 Gwajin Rabo
Gwajin Dangantakar Mataki na 3
4 Babu Asara Load Kuma Babu Load A Yanzu
5 Haɓakar Haɓaka Wutar Lantarki da Ƙarfafawa
6 Gwajin Karfin Wutar Lantarki
7 Gwajin Jurewar Wutar Lantarki
Gwajin Leak 8 tare da Matsi don Masu Canjin Ruwa na Immersed
9 Ma'aunin Resistance Insulation
Gwajin Dielectric Oil 10

300 KVA Dead Front Transformers test
300 KVA Dead Front Transformers fat test

 

04 Shiryawa da jigilar kaya

300 KVA Dead Front Transformers packing
300 kva dead front transformers-export-packing
300 kva dead front transformers-wooden crate packaging

 

05 Aikace-aikace

 

300 kVA dead front transformers application data centers
300 kVA dead front transformers application industrial manufacturer
300 kVA dead front transformers application residential community
Cibiyar Kwanan Wata Mai kera masana'antu Al'ummar Mazauna

 

 