75 kVA 3 Mataki Pad Dutsen Mai Canjawa-24.94 / 0.208 kV|Amurka 2024

75 kVA 3 Mataki Pad Dutsen Mai Canjawa-24.94 / 0.208 kV|Amurka 2024

Kasar: China 2024
Yawan aiki: 75kVA
Wutar lantarki: 24.94/0.208kV
Feature: tare da bayoneti fuse
Aika Aikace-aikacen

 

 

3 phase pad mount transformer

Ƙarfin aiki, mai ɗorewa kuma abin dogaro - -Pad Pad -Mounted Transformer, ƙashin bayan tsarin wutar lantarki!

 

01 Gabaɗaya

1.1 Fagen Aikin

75 kVA pad mounted transformer an isar da ita zuwa Kudancin Amurka a cikin 2024. Ƙarfin wutar lantarkin shine 75 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 24.94 / 14.4kV tare da ± 2 * 2.5% tapping range (NLTC), ƙarfin lantarki na biyu shine 0.208 / 0.12kV, sun kafa ƙungiyar vector na YNyn0, kuma shine madaidaicin ciyarwa. Wannan samfurin yana da sifofi na ƙananan girman, sauƙin shigarwa da kulawa, ƙaramar amo, ƙarancin asara, hana sata, cikakken kariya, ƙarfi mai ƙarfi da sauransu. Ana amfani da sabbin wuraren zama, koren bel, wuraren shakatawa, otal-otal, wuraren gine-gine, filayen jirgin sama da sauran wurare. An karɓi tsarin majalisar ministoci mai zaman kansa, kuma saman majalisar yana da niyyar sauƙaƙe magudanar ruwa mai inganci. Za'a iya haɗa nau'ikan maɓalli da kayan kariya daban-daban, suna sa mai canzawa ya zama mafi ƙarancin tsari, ƙarin cikakken aiki, ingantaccen aiki mai dogaro.

 

1.2 Ƙayyadaddun Fasaha

Nau'in ƙayyadaddun ƙayyadaddun wutar lantarki na KVA da takaddar bayanai

Isarwa zuwa
Kudancin Amurka
Shekara
2024
Nau'in
Tashin wutar lantarki
Daidaitawa
IEEE C57.12.00
Ƙarfin Ƙarfi
75 KWA
Yawanci
60HZ
Mataki
3
Nau'in Sanyi
ONAN
Babban Voltage
24.94GRDY/14.4 KV
Na biyu Voltage
0.208GrdY/0.12 KV
Abubuwan Iska
Aluminum
Matsala ta kusurwa
YNyn0
Impedance
3%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
0.08KW
Akan Rasa Load
1.27KW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

75 KVA kushin da aka ɗora zane da girman zane.

3 phase pad mount transformer  diagram 3 phase pad mount transformer drawing

 

 

02 Masana'antu

2.1 Kori

Nau'in ginshiƙi na uku{0}nau'i biyar kuma ana kiransa nau'in nau'in karkiyar ginshiƙi uku{1}, wanda aka kafa ta hanyar ƙara karkiya ta gefe biyu (babu cibiya mai ɗaukar nauyi) zuwa wajen ginshiƙi ukun- kashi uku, amma ɓangaren giciye da tsayin karkiyar ƙarfe na sama da na ƙasa sun yi ƙanƙanta fiye da na nau'in nau'in kwaya uku{3}} talakawa iri uku. Wannan yana rage tsayin gabaɗayan gidan wuta. An kwatanta ginshiƙi na guda uku{6}}phase biyar- tare da ginshiƙan lokaci guda uku{{8}, kuma akwai ƙarin ginshiƙan ginshiƙan reshe biyu a gefen hagu da dama na ginshiƙi don zama karkiya ta gefe. An saita windings na kowane matakin ƙarfin lantarki a kan ginshiƙai na tsakiya guda uku bisa ga matakin, kuma karkiya ta gefe ba ta da iska, ta yadda za a samar da taswira guda uku{10}fase biyar{11}.

pad mount transformer iron core

 

2.2 Guda

3 phase pad mount transformer winding

Amfanin Waya -Mai Girman Rauni{1}} Wutar Lantarki

1. Kyakkyawan Insulation

2. Babban Amfani da Sarari

3. Kyakkyawan Rage Zafi

4. Balagagge Tsari na Masana'antu

Amfanin Karfe -Rauni - Wutar Lantarki

1. Rage asarar Juriya

2. Babban Ƙarfin ɗauka na Yanzu:

3. Ingantacciyar Ƙarfin Ƙarfin Ƙarfi

4. Kyakkyawan Ƙarfin Ƙarfi

 

2.3 Tanko

An yi tankin da bakin karfe, wanda ke da ƙarfi da ƙarfi. An lulluɓe saman saman ƙarfe da abin rufe fuska{1} don hana lalacewa ta hanyar tasirin muhalli na waje. An amince da tsarin majalisar ministoci mai zaman kansa, saman majalisar yana da niyyar sauƙaƙe magudanar ruwa mai inganci, kuma majalisar tana da sauƙin shigar da abubuwan.

3 phase pad mount transformer tank

 

2.4 Taron Karshe

3 phase pad mount transformer assembly

1. Shigar da iska: Dutsen babban ƙarfin wutar lantarki da ƙarancin wutar lantarki, haɗa jagororin, da tabbatar da ingantaccen rufin.

2. Insulation da Gwaji: Ƙara kayan haɓakawa da yin tsayayya da ƙarfin lantarki da gwaje-gwajen fitarwa.

3. Rukunin Rukunin: Sanya core da windings a cikin casing kuma kammala aikin rufewa.

4. Na'urorin haɗi: Shigar da abubuwa masu mahimmanci kamar ma'aunin mai, masu kula da zafin jiki, da masu bushewa.

5. Cika Mai (na Man Fetur -Masu Canjin Ruwa): Tsaftace cika man tasfoma, daidaita matakin mai, kuma tabbatar da cewa babu kumfa mai iska.

 

 

03 Gwaji

1. Gwajin juriya na DC.

2. Gwajin juriya na insulation.

3. Ma'auni na ƙarfin lantarki da ƙungiyar vector.

4. Rarrabe tushen ac jure gwajin ƙarfin lantarki.

5. Induced ac jure ƙarfin lantarki gwajin.

6. Ma'auni babu -asara kuma babu kaya na halin yanzu.

7. Ma'auni nauyi da impedance.

8. Resistance hasara da inganci.

9. Gwajin hatimi.

 

3 phase pad mount transformer test
75kva transformer test

 

 

04 Shiryawa da jigilar kaya

3 phase pad mount transformer packing
3 phase pad mount transformer shipping

 

 

05 Yanar Gizo da Takaitawa

Na gode don sha'awar ku ga kushin mu guda uku - wanda aka ɗora{1} A matsayin maƙasudin ma'auni don amintaccen, ingantaccen, da ingantaccen hanyoyin rarraba wutar lantarki, ana gane wannan samfurin don ƙwararren aikin sa, ƙaƙƙarfan ƙira, da ingantaccen ƙarfin kuzari, yana samun amincin abokan ciniki a cikin masana'antu daban-daban. Ko don aikace-aikacen zama, kasuwanci, ko masana'antu, mun himmatu wajen samar da ayyuka na musamman don taimaka muku gina ingantaccen tsarin wutar lantarki. Muna fatan yin aiki tare da ku don ƙirƙirar makoma mai haske don hanyoyin warware wutar lantarki mai hankali! Don ƙarin bayani, da fatan za a iya tuntuɓar mu, kuma za mu yi farin cikin taimaka muku!