500 KVA IEC 60076 Mai Rarraba Rarraba-22 / 0.415 KV|Australia 2025
Yawan aiki: 500kVA
Wutar lantarki: 11/0.415 kV
Siffar: Karamar motar bas ɗin jan ƙarfe-arancin wutar lantarki
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin masana'antun da suka fi dacewa kuma masu samar da 500 kva iec 60076 na'ura mai rarrabawa -22/0.415 kv|Ostiraliya 2025 a China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Man fetur -Transfomar rarrabawa mai nutsewa: man - sanyaya, dutsen{2}} - yana kiyaye kowace watt, kowace rana.
01 Gabaɗaya
1.1 Bayanin Aikin
500 kVA IEC 60076na'ura mai rarrabawaAn isar da shi zuwa Ostiraliya a cikin 2025. Ƙarfin ƙimar wutar lantarki na IEC 60076 mai rarrabawa shine 500 kVA tare da sanyaya KNAN. Babban ƙarfin lantarki shine 22 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.415 kV, sun kafakungiyar vectorda YNyn0.
Wannan 500kVA, uku -, na'ura mai rarrabawa ta hermetically an ƙera shi don matsananciyar muhallin waje, yana bin ka'idodin IEC 60076 da AS/NZS, yana ba da ingantaccen aiki (Mafi girma ko daidai da 99.16%) da ingantaccen aiki a ƙarƙashin matsanancin yanayi (har zuwa yanayin yanayi na 50).
Mabuɗin Halayen Fasaha
- Ruwan FR3:Mai yuwuwa, babba -wuta{1}}maki (Mafi girma ko daidai da digiri 300) ester na halitta, yana haɓaka amincin wuta da rayuwar rufi.
- Akwatin Cable HV:IP56- ƙididdigewa, cikakken rufewa, tare da shigarwar ƙasa da ƙarewar haɗin gwiwar gwiwar hannu don amintaccen haɗin haɗin yanayi.
- Akwatin Cable na LV tare da Faɗaɗɗen Busbar Bus ɗin Copper:Ƙididdiga mai ƙima ta IP56 gami da faɗaɗɗen sandunan bas na jan karfe da goyan baya don sauƙi, ƙarewar kebul na LV mai sassauƙa.
- Akwatin Tasha Tare da Na'urar Hulɗar Ruwa:Akwatin tashar tasha ta IP56 wanda aka sanye tare da 230V AC dumama dumama don hana haɓakar danshi da tabbatar da tsawon lokaci{2}} ikon sarrafa mutuncin kewaye.
- Lambobin sadarwa na Sakandare (Control):Yana ba da WTI (ƙarararrawar digiri 110 / balaguron digiri na 130), zafin mai, saurin matsa lamba, da ƙararrawar matakin mai - duk tare da lambobin AC 230V don haɗakar SCADA.
Wannan na'urar taswira ta haɗu da ƙarfi mai ƙarfi, eco{0} ruwa na FR3, da cikakkiyar kariya ta IP56, yana ba da amintaccen rarraba wutar lantarki a cikin mahalli masu buƙata.
1.2 Ƙayyadaddun Fasaha
500 kVA IEC 60076 nau'in ƙayyadaddun ƙayyadaddun kayan wuta da takaddar bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
Saukewa: IEC60076
|
|
Ƙarfin Ƙarfi
500 kVA
|
|
Yawanci
50HZ
|
|
Mataki
3
|
|
Nau'in Sanyi
KNAN
|
|
Babban Voltage
22 kv
|
|
Na biyu Voltage
0.415 kV
|
|
Abubuwan Iska
Copper
|
|
Ƙungiyar Vector
YNyn0
|
|
Impedance
5.75%±7.5%
|
|
inganci
Yafi ko daidai 99.16%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
Kasa da ko daidai da 0.95 kW
|
|
Akan Rasa Load
Kasa da ko daidai da 5.8 kW
|
1.3 Zane
500 kVA IEC 60076 zane mai rarrabawa da girman zane.
![]() |
![]() |
02 Masana'antu
2.1 Kori

Tushen wutar lantarki an yi shi ne da sanyin hatsin da aka yi birgima - silikon karfe mai daidaitacce tare da tsarin cinya mai tako. Zane-zanen da'irar maganadisu ya ci gaba kuma ya cika buƙatun aikin don ƙarancin asara da babban ƙarfi. Ƙirar da masana'antu sun dace da IEC 60076. Ma'auni na asarar nauyi shine kawai 0.785 kW (buƙatun Kasa da ko daidai da 0.95 kW), kuma babu-nauyi na yanzu shine 0.68% (buƙatun Kasa da ko daidai da 1.2%). Duk maɓallan maɓalli biyu sun fi iyakoki na yau da kullun, suna tabbatar da ingantaccen sarrafa hasara. Don tabbatar da inganci, core stacking yana amfani da ingantattun kayan aiki, kowane haɗin gwiwa ana sarrafa shi sosai, kuma a cikin aiwatar da aikin maganadisu ana yin samfurin. Mahimman bayanai na masana'antu: haɗin gwiwar ƙafar ƙafa, ƙarancin ƙarancin ƙarfe na silicon, cikakken aikin aikin maganadisu.
2.2 Guda
Iskar tana amfani da jan ƙarfe na lantarki tare da tsafta Sama da ko daidai da 99.9% da ingantattun hanyoyin iska, cike da cikar tafiyar da aikin da buƙatun thermal, da bin ƙa'idodin IEC 60076 don juriya da haɓakar zafin jiki. Ma'aunin zafin jiki na HV da aka auna shine 58.69 K (buƙatun Kasa da ko daidai da 60 K), haɓakar zafin jiki na LV shine 57.84 K (buƙatun ƙasa da ko daidai da 60 K), kuma matsakaicin juriya rashin daidaituwa shine kawai 0.41%. Waɗannan alkalumman suna nuna tsarin iska iri ɗaya da kyakyawan watsawar zafi. Tabbacin ingancin ya haɗa da injunan iska ta atomatik tare da sa ido na juriya na ainihin lokaci da kuma rufin Layer Layer. Mahimman bayanai na masana'antu: masu jagoranci na jan karfe mai tsafta, iska ta atomatik + saka idanu na juriya na gaske, rufin Layer multi-layer na tsawon rayuwa.

2.3 Tanko

ThetankiTsarin karfe ne cikakke wanda aka rufe tare da kariya ta IP56, babu mai adanawa kuma babu matashin nitrogen, cikakke dacewa da matsananciyar muhallin waje, kuma an tsara shi bisa ga IEC 60076 hatimi da ka'idojin kariya. Gwajin gwajin da aka yi a 15 kPa na tsawon awanni 24 bai nuna yabo ba, kuma gwajin ƙarfin lantarki da aka yi amfani da shi (HV gefen 50 kV / 60 s) ya wuce ba tare da fitowar ba, yana mai tabbatar da abin dogaro da hatimi da ƙarfin ƙarfin lantarki. Tabbacin inganci: 100% dubawa duk welds, cikakken gwajin hatimin matsi. Mahimman bayanai na masana'anta: ƙirar ƙirar ƙira mai cikakken hatimi, ƙimar kariya ta IP56, RAL7035 rufin lalata-resistant.
2.4 Taron Karshe
Ƙungiyar ƙarshe ta haɗa nau'o'i masu mahimmanci: FR3 na halitta ester man fetur (babban wuta, biodegradable, kare muhalli da aminci); HV gefen tare da rufin akwatin IP56 HV na USB, shigarwar ƙasa, masu haɗin haɗin gwiwar gwiwar hannu; Gefen LV tare da akwatin kebul na LV da ƙarin sandunan tagulla da goyan baya don saurin wayan filin; akwatin tasha tare da ginannen inti-condensation sarari hita (230V / 50W) don hana danshi; Cikakkun lambobi na wayoyi na biyu ciki har da mai nuna zafin jiki na iska, mai nuna zafin jiki, bawul ɗin taimako na matsa lamba, ƙararrawar matakin mai, da sauransu. An tsara duk abubuwan haɗin gwiwa bisa ga ƙa'idodin kayan haɗi na IEC 60076. Gwajin dogaro: jawo ƙarfin lantarki jure gwajin a 30.8 kV / 150 Hz na 40 seconds - babu rushewa; Gwajin bugun walƙiya a 125 kV cikakken igiyar ruwa - ya wuce. Wannan yana tabbatar da cikakken tsarin tsarin rufewa da ingantaccen aikin kayan haɗi. Tabbacin inganci: Gwajin aikin 100% na duk na'urorin haɗi kafin haɗawa, tabbatarwa ɗaya zuwa ɗaya na zane-zanen wayoyi akan ainihin kayan aiki, cikakken simulation yana gudana kafin aikawa. Mahimman bayanai na masana'antu: haɗe-haɗe akwatunan kebul na HV/LV, akwatin tasha mai zafi mai zafi, waɗanda aka riga aka shigar da lambobi na wayoyi na biyu.

03 Gwaji
Taswirar ta yi cikakken gwaje-gwaje na yau da kullun da nau'in gwaje-gwaje, tare da bin IEC 60076-1/2/3/10, tare da duk abubuwan da suka wuce kuma masu nuni da yawa fiye da buƙatu na yau da kullun. Sakamakon gwajin maɓalli: babu asarar nauyi 0.785 kW (mafi kyau fiye da ƙasa ko daidai da 0.95 kW), asarar nauyi 5.764 kW (mafi kyau fiye da ƙasa ko daidai da 5.8 kW), ƙarancin kewayawa 5.90% (a cikin haƙuri), HV mai iska mai zafi sama da 58.5 Kasa da ko daidai da 60 K kuma Kasa da ko daidai da 55 K bi da bi), gwajin gwajin 24h - babu yayyo, walƙiya cike da ƙarfi 125 kV - wuce, amfani da ƙarfin lantarki 50 kV / 60 s - wuce, matakin sautin sauti kawai 47.3 dB (A) (ko mafi kyau fiye da 7) 7. Tabbacin inganci: duk kayan aikin gwaji ana daidaita su akai-akai, ƙwararrun ma'aikatan gwaji, nazarin matakan gwaji uku. Mahimman bayanai na masana'antu: cikakken ɗaukar hoto na gwaji, bayanan da za a iya ganowa, yarda da ƙa'idodin ƙasa da ƙasa.


04 Shiryawa da jigilar kaya
4.1 Shiryawa

An cushe tafsirin a cikin wani katako mai ƙarfi mai ƙarfi ko firam ɗin ƙarfe. Ana sarrafa ma'auni na waje a cikin 2000 × 1400 × 1800 mm, jimlar nauyin da bai wuce 3200 kg ba, sararin samaniya da buƙatun kaya don kwantena daban-daban da jigilar kaya. Zane-zanen tattara kayan ya dace da ƙa'idodin fitarwa na duniya (misali, ISPM 15 buƙatun jiyya na zafi). Kafin shiryawa, ana kula da duka naúrar. Ana adana taswirar a cikin akwati tare da ɗaure maƙallan maki da yawa da kayan kwantar da hankali don hana lalacewar girgizar sufuri. Za a iya shigar da alamar girgiza ta zaɓi don saka idanu kan tasirin yayin tafiya. Tabbacin inganci: duban gani na ƙarshe da na aiki kafin shiryawa, cikakken kulawa da takaddun hoto na tsarin lodi. Mahimman bayanai na masana'antu: babban ƙarfin fitarwa-sa kayan tattarawa, haɗaɗɗen danshi da kariyar girgiza, alamar girgiza na zaɓi.
4.2 Shipping
Ana jigilar kayayyaki ta teku zuwa tashar jiragen ruwa na Fremantle, Ostiraliya, ƙarƙashin sharuɗɗan CIF, tare da ƙaddamar da ranar bayarwa na Maris 15, 2026. Tsarin sa ido na sufuri na zaɓi na zaɓi zai iya rikodin yanayin zafi na ainihin lokacin, zafi, girgiza, da bayanan wuri, yana tabbatar da cikakken ganowa. Tsarin jigilar kaya ya dace da buƙatun IEC 60076 don yanayin sufuri. Kafin aika, taransfoma ta kammala duk gwaje-gwaje kuma an kulle dukkan sassa masu motsi. Amincewa: Ana amfani da nazarin girgizar sufuri don inganta tsarin gyarawa, kuma ana yin gwajin gwajin gwaji kafin jigilar kaya. Tabbacin ingancin ya haɗa da zaɓin mai ba da dabaru ƙware a jigilar kayan wuta, alamar ƙarshe ta ingantattun ingantattun kafin aikawa, da samar da inshorar sufuri. Mahimman bayanai na masana'antu: tsarin sa ido na sufuri na ainihi na zaɓi, cikakken kayan aikin ganowa, tsananin riko da ranar bayarwa.

05 Taƙaitaccen
A taƙaice, wannan 500 kVA / 22 kV / 0.415 kV mai rarraba wutar lantarki mai rarraba mai yana aiki da kyau a cikin ainihin, iska, tanki, taro na ƙarshe, gwaji, tattarawa da jigilar kaya. Bayanan da aka auna suna nuna asarar nauyi 0.785 kW, asarar nauyi 5.764 kW, HV zafin jiki mai iska 58.69 K, saman zafin mai ya tashi 49.53 K, gajeriyar rashin ƙarfi 5.90%, gwajin gwaji 24h ba yayyo, walƙiya yunƙurin wuce, matakin ƙarfin lantarki ya wuce 125 kV0 kawai 47.3 dB (A) - duk alamomi sun wuce kuma da yawa sun fi kyau fiye da bukatun al'ada. Ayyukan masana'antu tare da ingantaccen kulawar inganci da cikakken gwajin tsari suna tabbatar da daidaiton samfur da amincin. Mahimman bayanai sun haɗa da: ƙananan hasara tako core, high-tsaftataccen jan karfe windings, cikakken shãfe haske IP56 corrugated tank, FR3 muhalli abokantaka high-wuta-point man fetur, HV na USB akwatin, LV na USB akwatin tare da mika tagulla sanduna, anti-condensation m akwatin, da kuma cikakken sakandare wiring lambobin sadarwa. Wannan na'ura mai jujjuyawar tana da cikakkiyar dacewa don matsananciyar yanayin waje, biyan buƙatun ingantaccen inganci, ƙarancin kulawa, da babban aminci.

Hot Tags: IEC 60076 mai rarraba wutar lantarki, masana'anta, mai siyarwa, farashi, farashi
You Might Also Like
2250 kVA Kushin Haɗa Mai Canjawa-12.47 / 0.6 kV|Amur...
2000 kVA Mai Rarraba Wutar Lantarki-20 / 0.4 kV|Alba...
75 kVA 3 Mai Rarraba Rarraba Mataki-0.22 / 0.415 kV|...
2000 KVA Rarraba Mai Canjawa-11 / 0.433 KV|Malaysia ...
750 KVA Mai Rarraba Wutar Lantarki-11 / 0.415 KV|Pap...
500 KVA Rarraba Mai Canjawa-11 / 0.415 KV|Australia ...
Aika Aikace-aikacen