2000 kVA Mai Rarraba Wutar Lantarki-20 / 0.4 kV|Albaniya 2024

2000 kVA Mai Rarraba Wutar Lantarki-20 / 0.4 kV|Albaniya 2024

Kasar: Albaniya 2024
Yawan aiki: 2000kVA
Wutar lantarki: 20/0.4kV
Feature:tare da buchholz relay
Aika Aikace-aikacen

 

 

power distribution transformer

Gadar watsa wutar lantarki, kashin bayan makamashi{0}masu canza wuta suna sa wutar lantarki ta gudana ba tare da wata matsala ba!

 

01 Gabaɗaya

1.1 Fagen Aikin

Farashin 2MVAna'ura mai rarrabawaAn isar da shi zuwa Albaniya a cikin 2024. Ƙarfin wutar lantarki na rarraba wutar lantarki shine 2000 kVA tare da sanyaya ONAN, ƙarfin farko shine 20 kV tare da ± 2 * 2.5% tapping range @ HV side (NLTC), ƙarfin lantarki na biyu shine 0.4 kV, sun kafa ƙungiyar vector na Dyn5.Man fetur -Transfoma mai rarrabawayana da sifofi na ceton makamashi da kariyar muhalli, ƙarancin asara, ƙaramar hayaniya, babban nauyi, ƙarfin injina, ƙarfin gajere mai ƙarfi{0}}ƙarar juriya, ƙaramin juzu'i, kwanciyar hankali mai kyau, babban aminci, tsawon rayuwar sabis da sauransu. Amintacciya, mai hana gobara, gurɓatacce - kyauta, ana iya sarrafa shi kai tsaye a cikin wurin ɗaukar kaya, kuma ana iya amfani da shi sosai a masana'antu, noma, sufuri, al'ummomin birane da sauran fannoni, yayin da sabbin tashoshin wutar lantarki, cibiyoyin bayanai, tashoshi na 5G, dumama da sauran filayen za su iya adana makamashi yadda yakamata da rage yawan amfani da hayaki. Ta hanyar madaidaicin ampere - yana juya lissafin ƙarfin ma'auni, jiyya mai ƙima don tsayayya da iska, rarraba iri ɗaya da haɗakarwa, kariyar ƙarfi ta musamman. Bugu da ƙari, flange ɗin rufewa yana ɗaukar tsarin tsagi, bawul ɗin fitar da mai yana ɗaukar bawul ɗin jan ƙarfe, kuma radiator yana ɗaukar bawul ɗin malam buɗe ido don tabbatar da aikin rufewa.

 

 

1.2 Ƙayyadaddun Fasaha

2000 kVA ikon rarraba wutar lantarki nau'in ƙayyadaddun ƙayyadaddun bayanai da takaddar bayanai

Isarwa zuwa
Albaniya
Shekara
2024
Nau'in
Wutar lantarki
Daidaitawa
Saukewa: IEC60076
Ƙarfin Ƙarfi
2000kVA
Yawanci
50HZ
Mataki
3
Nau'in Sanyi
ONAN
Babban Voltage
20 kV
Na biyu Voltage
0.4 kV
Abubuwan Iska
Copper
Matsala ta kusurwa
Din5
Impedance
6%
Matsa Canji
Farashin NLTC
Taɓa Range
± 2*2.5% @HV gefe
Babu Asara Load
1.95 kW
Akan Rasa Load
19.14 kW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

2000 kVA ikon rarraba wutar lantarki zane da girman zane.

power distribution transformer drawing power distribution transformer nameplate

 

 

02 Masana'antu

2.1 Kori

Babban kayan an yi shi ne da ƙarancin ƙarfi da ƙaramin asara silikon karfe takardar tare da kyakkyawan aiki, yadda ya kamata yana rage asara da hayaniya. Iron core yana ɗaukar nau'i mai yawa{2}mataki duk-tsarin haɗin gwiwa, don rarraba filin maganadisu a haɗin gwiwar ƙarfen ƙarfe ya fi kyau, kuma a'a{4}}asara da hayaniya ta ragu. Coil ta amfani da nau'in waya mai dacewa, kamar takarda{6}}waya mai rufaffiyar waya ko kai{7}}wayar juyewa, yana rage asarar kaya yadda yakamata. Yana iya rage ƙimar aiki na grid ɗin wutar lantarki yadda ya kamata da masu amfani.

power distribution transformer steel core

 

2.2 Guda

power distribution transformer electrical coils

Nada yana ɗaukar tsarin elliptic. Ƙarƙashin wutar lantarki - an naɗe shi da foil kuma an rufe shi da manyan{2}}A-E class insuulation kayan; Babban ƙarfin wutan lantarki yana rauni tare da wayar jan karfe don inganta juriyar walƙiya. The axial ampere - yana juya da'irar maganadisu na coil ana rarraba daidai gwargwado, wanda zai iya rage ƙarfin injin kuma ya inganta ƙarfin gajeriyar kewayawar nada.

 

2.3 Tanko

Ana fesa saman samfurin tare da fenti bayan cire man fetur, yin sutura da gyaran yashi, wanda ke da juriya mai kyau kuma yana iya saduwa da buƙatun musamman na tsarin ƙarfe da petrochemical da rigar da datti. Ya dace da aiki a cikin matsanancin zafi da sauran wurare masu tsauri. Jiki da tankin man fetur suna da tsari mai tsauri, don haka ba shi da sauƙi don motsawa yayin sufuri. Samfurin na iya kasancewa koyaushe yana karko yayin aiki na dogon lokaci{3}.

power distribution transformer tank

 

2.4 Taron Karshe

power distribution transformer assembly
power distribution transformer active part

 

 

03 Gwaji

1. Ma'auni Na Voltage Ratio Da Duban Matsalolin Mataki

2. Ma'aunin Juriya na iska

3. Measurement Of DC Insulation Resistance Between Each Winding To Earth And Between Windings

4. Auna A'a -Asarawar Load da Yanzu

5. Jarabawar Juriya da Wutar Lantarki

6. Auna Gajeren -Cikin Tasirin kewayawa da Rasa Load

7. Gwajin Karfin Wutar Lantarki (AV)

8. Gwajin mai

9. Gwajin Leak Tare da Matsi Don Ruwan Ruwa{1}}Masu Canja-canje (Gwajin Tsattsauran ra'ayi)

 

power distribution transformer testing
power distribution transformer FAT

 

 

04 Shiryawa da jigilar kaya

power distribution transformer packing

power distribution transformer shipping

 

05 Yanar Gizo da Takaitawa

Na'urar rarraba wutar lantarki sune kayan aiki masu mahimmanci a tsarin wutar lantarki, tabbatar da ingantaccen, barga, kuma amintaccen watsa makamashi da rarrabawa.Taranfoma na muan gina su tare da fasaha na ci gaba da tsauraran matakan masana'antu, suna ba da tabbacin ingantaccen inganci da ingantaccen aiki. Suna ba da tallafin ƙarfi mai ƙarfi don aikace-aikacen masana'antu, kasuwanci, da na jama'a. Ta hanyar zabar samfuranmu, kuna samun dorewa da ingantaccen hanyoyin samar da makamashi, ɗaukar mataki tare da mu zuwa mafi inganci da dorewa nan gaba!