100 KVA Hasken Wuta Mai Wuta-13.8 / 0.12 * 0.24 KV|Amurka 2025
Yawan aiki: 100 kVA
Wutar lantarki: 13.8-0.12/0.24kV
Fasalin: HV mai iska: Copper, LV winding: Aluminum

Amintacce, inganci, da babban aiki - - injin wutan sandar wuta mai nauyin kVA 100 yana ba da ƙarfi mai ƙarfi don buƙatun hanyoyin rarraba Arewacin Amurka
01 Gabaɗaya
1.1 Bayanin Aikin
100 kVA na'urar wutan lantarki an yi niyya don 13.8 kV tsarin rarraba sama da ƙasa uku don samar da mafi girman nauyi{3}, kamar wuraren zama masu yawa ko ƙananan wuraren kasuwanci. Hakanan ya dace da IEEE C57.12.20, fasali na ONAN sanyaya tare da rufin mai mai ma'adinai, da babban -ƙararfin jan ƙarfe da ƙarancin ƙarfin wutar lantarki na aluminum. Fitowar na biyu shine 120/240 V. A'a - asarar kaya yana kusan 0.25 kW, asarar nauyi 0.897 kW, wanda ya haifar da asarar duka 1.147 kW, yayin da inganci ya kasance sama da 98%.
Impedance shine 2.86%, daidai da daidaitattun masu rarrabawa. Hakanan wannan rukunin yana sanye take da mai canza famfo na NLTC babu{2}, da raƙuman ɓangarorin sa da ƙungiyar Ii0 vector suna tabbatar da daidaitawar lokaci tare da taswirar kVA 50 daga tsari iri ɗaya. Tare, waɗannan na'urori guda biyu suna ba da ingantaccen inganci, ƙarancin asara, da ingantaccen daidaitawa, ba da aminci da ingantaccen ƙarfi ga cibiyoyin rarrabawar Arewacin Amurka.
1.2 Ƙayyadaddun Fasaha
100kVA guda lokaci iyakacin duniya saka gidan wuta ƙayyadaddun bayanai da takardar bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
lokaci guda iyakacin duniya saka taransifoma
|
|
Daidaitawa
IEEE C57.12.20
|
|
Ƙarfin Ƙarfi
100 KVA
|
|
Yawanci
60HZ
|
|
Mataki
Single
|
|
Nau'in Sanyi
ONAN
|
|
Liquid insulant
Ma'adinan Mai
|
|
Babban Voltage
13.8 kV
|
|
Na biyu Voltage
0.12 / 0.24 kV
|
|
Ƙungiyar Vector
Ii0
|
|
Polarity
Ragewa
|
|
Abubuwan Iska
HV: Copper, LV: Aluminum
|
|
Impedance
2.86%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
14400,13800,13200,12870,12540
|
|
Babu Asara Load
0.25 KW
|
|
Akan Rasa Load
0.897 kW
|
|
Na'urorin haɗi
Daidaitaccen Kanfigareshan
|
1.3 Zane
100kVA kushin lokaci guda ɗaya wanda aka ɗora taswirar zane da girman.
![]() |
![]() |
02 Masana'antu
2.1 Kori
Ciwon rauni ya haɗu da tanadin makamashi da ingantaccen kayan aiki. An gina shi daga hatsi{1}}ƙarfe na silicon, an yi masa rauni a cikin mafi kyawun alkiblar maganadisu don cimma kyakkyawan juzu'i. Mabuɗin yana kiyaye ƙaƙƙarfan kaddarorin maganadisu ƙasa da matakin jikewa. Tunda akwai ƙarancin haɗin gwiwa fiye da dunƙule dunƙule, yana iya rage murdiya sosai, babu{4}}asara, da amo.
2.2 Guda
An ƙera iskar HV tare da yadudduka masu tattara bayanai ta amfani da babban madugu na jan karfe mai tsafta, wanda aka keɓance shi da murfin enamel don ingantacciyar ƙarfin dielectric da juriya na zafi har zuwa digiri 105. The LV winding yana amfani da tsiri na aluminium, yana ba da babban yanki, ingantacciyar sanyaya, da ingantaccen aikin lantarki a ƙarƙashin yanayin nauyi mai nauyi.

2.3 Tanko

An ƙera tankin daga ƙarfe mai laushi tare da jikin silinda da murfin da aka keɓe, an gama shi da fenti RAL7035. Ba a yarda dubawa ko buɗe sabis ba. Biyu masu ƙarfi masu tsayi masu ƙarfi tare da kauri na aƙalla 3.4 mm suna welded zuwa tanki. An lanƙwasa iyakar don dacewa da dacewa. Duk welds dole ne su kasance daidai da santsi. Dole ne kada su kasance da ramuka kuma ya kamata a kasa bayan walda.
2.4 Taron Karshe
1. Tauraron Iska:Zamar da iskar HV/LV a kan madaidaicin laminated, yana tabbatar da daidaitaccen jeri da amincin rufi.
2. Haɗin Wutar Lantarki:Haɗa iska tana kaiwa zuwa mai canza famfo, bushings, da sauran abubuwan da aka gyara, sannan a kiyaye da kuma rufe mahaɗin.
3. Core -Bushewar Naɗi:Sanya sashin da aka haɗa (core + windings) a cikin tanda mai bushewa don dumama don cire danshi.
4. Shigar Tanki:Sanya busassun sashin aiki a cikin tanki, sanya shi amintacce, kuma tabbatar da ingantaccen rufin bangon tanki.
5. Na'ura mai hawa:Shigar da bushings, bawul ɗin taimako na matsa lamba da sauran na'urorin haɗi, sa'an nan kuma bincika ɗigogi.
6. Ciko Mai & Matsala:Cika da mai mai hana ruwa, gurɓataccen ruwa, da ba da izinin daidaitawa kafin auna matakan mai da ƙarfin wutar lantarki.

03 Gwaji
Matsayin Gwaji da Gwajin Na yau da kullun
IEEE C57.12.20 -2017: Matsayin IEEE don Nau'in Rarraba Masu Canjin Sama 500 kVA da Karami; Babban Voltage, 34500 V da ƙasa; Low Voltage,7970/13 800YV da kasa
IEEE C57.12.90 -2021: IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and regulating Transformers
CSA C802.1 -13(R2022): Mafi ƙarancin ƙimar inganci don masu rarrabawa mai cike da ruwa
1. Ma'aunin Juriya
2. Gwajin Rabo
3. Gwajin Polarity
4. Babu Asara Load Kuma Babu Load A Yanzu
5. Load Loss da Impedance Voltage
6. Gwajin Karfin Wutar Lantarki
7. Gwajin Juriya da Ƙarfin Wutar Lantarki
8. Ma'aunin Juriya na Insulation
9. Gwajin Leak tare da Matsi don Masu Canjin Ruwa na Immersed
10. Gwajin Dielectric Oil
04 Shiryawa da jigilar kaya

05 Yanar Gizo da Takaitawa

100 kVA guda ɗaya -ƙaran sandar lokaci{2}} wanda aka ɗora tasfoma yana aiki don cibiyoyin rarraba saman saman Amurka ta Arewa. Yana ba da ingantaccen ƙarfi ga gidaje da ƙananan kasuwanci. Yana amfani da sanyaya mai ONAN. An yi iskar tagulla da aluminium mai inganci{{6}. Tankin yana da ƙarfi kuma an rufe shi don dogon amfani. Ba shi da mai sauya matsa lamba don daidaita wutar lantarki. Transformer yana aiki karɓuwa da inganci. Scotech yana yin kowane taswira a hankali. Kowane yanki ya cika ka'idodin duniya.
Hot Tags: wuta sandar wuta transformer, manufacturer, maroki, farashin, tsada
You Might Also Like
75 kVA Pole Type Transformer-34.5 / 0.12 * 0.24 kV|K...
100 kVA Mai Canja wurin Wuta na Wuta-34.5 / 0.24 kV|...
150 kVA Pmt Mai Canjawa-19.92 / 0.24 * 0.12 kV|Kanad...
167 kVA Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarƙ...
167 kVA Cooper Kushin Haɗa Mai Canjawa-13.8 / 0.24 k...
50 kVA Mai Canjawa Akan Ƙarfin Wuta-7.97 / 0.12 / 0....
Aika Aikace-aikacen