2500 KVA Kushin Haɓaka Masu Fassara Manufacturer Usa-12.47/0.48 KV|Amurka 2025
Yawan aiki: 750 kVA
Wutar lantarki: 12.47D-0.48Y/0.277 kV
Siffar: tare da mai FR3
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin masana'antun da suka fi dacewa kuma masu samar da 2500 kva pad ɗorawa masana'antar taswira ta usa{6}}12.47/0.48 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Yanayi{0}}hujja, tsayayyen fitarwa, damuwa{1}} zaɓi na kyauta - pad{3}}wanda aka ɗora tafsiri, amintaccen rarraba wutar lantarki a waje.
01 Gabaɗaya
1.1 Bayanin Aikin
2500 kVAkushin saka transformerAn isar da shi zuwa Amurka a cikin 2025. Ƙarfin wutar lantarki na wutar lantarki shine 2500 kVA tare da sanyaya KNAN. Babban ƙarfin lantarki shine 12.47D kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.48Y / 0.277 kV, sun kafa ƙungiyar vector na Dyn1.
Wannan 2500kVA da aka ɗora tafsirin tafsiri an ƙirƙira shi don aikin madauki{1}aikin ciyarwa, yana ba da damar kwararar wutar lantarki guda biyu da keɓewar kuskure a cikin amintattun madaukai masu rarraba. Yana amfani da ruwa mai ester na halitta na FR3, wanda ke ba da wurin wuta sama da digiri 300 da cikakken biodegradability, yayin bin bin umarnin.DOE makamashi yadda ya dacebukatun don rage hasara. Yakin yana foda mai rufi a cikin farin (RAL 9003) don tsayin daka don juriya ga lalata da bayyanar UV. An haɗa haɗaɗɗun masu kamawa don kare kariya daga abubuwan da suka faru na wuce gona da iri, suna sanya wannan rukunin ya zama manufa don buƙatar aikace-aikacen ɗorawa na waje kamar wuraren shakatawa na masana'antu,cibiyoyin bayanai, da kuma hada-hadar kasuwanci. mu masu sana'ar canjin wuta ne a Amurka.
1.2 Ƙayyadaddun Fasaha
2500 kVA kushin da aka ɗora masana'antun taswira ta amfani da nau'in ƙayyadaddun bayanai da takaddar bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
IEEE Std C57.12.34-2022 DOE 2016
|
|
Ƙarfin Ƙarfi
2500 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
KNAN
|
|
Babban Voltage
12.47D kV
|
|
Na biyu Voltage
0.48Y/0.277 kV
|
|
Abubuwan Iska
Aluminum
|
|
Ƙungiyar Vector
Dyn1
|
|
Impedance
6.3%
|
|
inganci
99.53%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
2.4 kW
|
|
Akan Rasa Load
15.79 kW
|
1.3 Zane
2500 kVA kushin da aka ɗora masana'antar taswira Amurka zane da girman zane.
![]() |
![]() |
1.4 Aikace-aikacen Ayyuka
Wannan jeri na pad - an ƙera tafsirin tafofi don cibiyoyin sadarwa a Arewacin Amurka da sauran kasuwannin duniya. Aikace-aikace na yau da kullun sun haɗa da:
- Babban birni- rukunin kasuwanci, manyan gine-gine{0}, asibitoci, makarantu, inda ƙaƙƙarfan sawun ƙafa da ƙayatarwa ke da mahimmanci.
- wuraren shakatawa na masana'antu & cibiyoyin bayanai- buƙatar babban abin dogaro, babban ƙarfin yin nauyi, da ƙaramar amo.
- Ci gaban wurin zama & al'umma– madauki ko radial tsarin rarraba karkashin kasa.
- Sabunta makamashi & cajin EV- photovoltaic, ajiyar makamashi, da tashoshi na caji na EV suna buƙatar waje, ɓarna{0}mai jurewa, da shigarwar gani.
Duk raka'a suna da cikakken ruɓaɓɓen gini, mai jujjuyawar gini{0}wanda ya dace da sabis na waje na tsawon shekara yayin saduwa da ƙaƙƙarfan buƙatun aminci ga ma'aikata.
02 Masana'antu
2.1 Kori
Ƙananan hasara, ƙananan amo - tushe na inganci
- Daidaita Siga- Sashe na ƙwanƙwasa da yawan juzu'i an tsara su daidai gwargwadon ƙarfin ƙima, ƙarfin lantarki, da buƙatun asarar nauyi don tabbatar da cewa babu jikewa da ke faruwa ƙarƙashin bambance-bambancen ƙarfin lantarki na yau da kullun.
- Ka'idojin Biyayya- Babu hasara mai kayatarwa da abubuwan ban sha'awa na yanzu sun hadu da matakan dacewa na DOE 2016; ƙirar injina ya dace da IEEE Std C57.12.34-2022 don masu taswira da aka saka.
- Dogara (Gwaji)- Ba a tabbatar da asarar nauyi da matakin sauti akan kowane babban tsari don tabbatar da kwanciyar hankali da aikin hayaniya a tsawon rayuwar samfurin.
- Tabbacin Inganci (Kira)– High-permeability hatsi-daidaitacce silicon karfe da ake amfani; Ana sarrafa ma'auni akan layukan ƙetare ta atomatik don sarrafa bursu da daidaito. Ba a yi rikodin bayanan gwajin da ba za a iya gano su ba kowace raka'a.


2.2 Guda
Madaidaicin sigogin lantarki - haɓaka ƙarfin gajeriyar kewayawa
- Daidaita Siga- Ana ƙididdige kayan sarrafawa (tagulla / aluminium), ɓangaren giciye, da kauri mai kauri dangane da rashin ƙarfi na tsarin, iyakokin hawan zafin jiki, da kewayon famfo don daidaitattun buƙatun filin.
- Ka'idojin Biyayya- Tsarin insulation da ƙarfin jujjuyawar tsaka-tsaki sun dace da yunƙurin walƙiya da ƙarfin juriya da gwaje-gwajen da aka ayyana a cikin IEEE Std C57.12.34-2022.
- Dogara (Gwaji)- Bayan iska, kowane coil ana gwada shi don juriya na DC, jujjuya rabo, da jan wutar lantarki don gano kowane gajerun wando na juyi ko lahani.
- Tabbacin Inganci (Kira)- Injunan jujjuyawar wutar lantarki na yau da kullun suna hana lalacewar madugu; Ana haɗa haɗin gubar bisa ga ingantattun hanyoyin walda, tare da duban gani 100% da kuma duban X-ray bazuwar.


2.3 Tanko
An rufe cikakke, juriya-lalata - an gina shi don wurare masu tsauri
- Daidaita Siga- Girman tanki da yanayin sanyaya an keɓance su da ƙididdige yawan zafin jiki, yana tabbatar da yanayin zafin mai ya kasance cikin iyaka har ma da cikakken kaya da yanayin yanayin yanayi.
- Ka'idojin Biyayya– Seling da ingress kariyar sun hadu da IEEE Std C57.12.34-2022 buƙatun don tsantsar ruwa, juriyar lalata, da gini mai jurewa.
- Dogara (Gwaji)- An gwada jikin tanki a 0.2 MPa (iska) don tsauri; Ana yin gwajin yabo na biyu bayan taro na ƙarshe. Ana tabbatar da sutura ta hanyar gwajin fesa gishiri.
- Tabbacin Inganci (Kira)– Welding yana biye da ingantattun hanyoyin WPS; Ana bincika weld mai mahimmanci ta hanyar duban ɗan adam ko rini. An yi samfurin kauri da mannewa a kowane tsari.


2.4 Taron Karshe
Tsaftace taro - tabbatar da daidaiton naúrar
- Daidaita Siga- Dangane da ƙayyadaddun abokin ciniki (maɓallin ɗaukar nauyi, fuses, masu haɗin gwiwar gwiwar hannu, da sauransu), duk haɗin ciki, saitunan maɓalli, da na'urorin haɗi ana shigar daidai don dacewa da kebul na yanar gizo.
- Ka'idojin Biyayya- Tsare-tsare na lantarki, nisan rarrafe, da tsarin ƙasa suna bin IEEE Std C57.12.34-2022.
- Dogara (Gwaji)- Bayan haɗuwa, kowane mai canzawa yana fuskantar juriya na insulating, factor factor, juya rabo, da babu-load/load gwaje-gwaje don tabbatar da gaba ɗaya aikin lantarki.
- Tabbacin Inganci (Kira)– Mahimman ayyuka (sayar da gubar, naɗaɗɗen rufi) suna ƙarƙashin binciken labarin farko da duban aiki. Ana kiyaye cikakken gano ma'aikatan taro da kuri'a na kayan aiki.


03 Gwaji
Tabbatar da cikakken ma'auni - isarwa mara kyau
- Daidaita Siga- Gwajin ƙarfin lantarki, igiyoyi, da mitoci sun dace daidai da ƙimar suna; ana kiyaye ma'auni a cikin daidaitattun haƙuri dangane da maƙasudin ƙira.
- Ka'idojin Biyayya- Ana yin gwaje-gwaje na yau da kullun da nau'in gwaje-gwaje daidai da IEEE Std C57.12.34-2022 da DOE 2016 ƙa'idodin gwajin inganci; ana fitar da rahotannin gwajin ganowa.
- Dogara (Gwaji)- Bugu da ƙari ga daidaitattun gwaje-gwajen dielectric da asarar, ana aiwatar da ma'aunin fitarwa na ɓangarori da ƙididdigar ƙarfin ƙarfin mai-samfurin don gano yuwuwar raunin rufewa.
- Tabbacin Inganci (Kira)– Dukkanin kayan aikin gwaji an daidaita su ta ƙwararrun dakunan gwaje-gwaje na ɓangare na uku. Ana yin rikodin bayanan gwaji ta atomatik kuma ana adana su a cikin ma'ajin inganci; gwajin shaida ta abokan ciniki (a kan layi ko nesa) ana tallafawa.
04 Shiryawa da jigilar kaya
4.1 Shiryawa
Kariyar sana'a - shirye don jigilar kayayyaki da yawa
- Daidaita Siga– Girman tattarawa da tsakiyar-na nauyi an ƙera su don dacewa da iyakokin kwantena da manyan motoci, guje wa tsayi sama da ƙasa, sama da faɗin, ko lodi mara daidaituwa.
- Ka'idojin Biyayya- Kayan tattarawa da fumigation sun bi ISPM 15 don jigilar kayayyaki na duniya, biyan buƙatun izinin kwastam.
- Dogara (Gwaji)- Kwaikwayon sufuri (jigilar girgizawa da gwajin juzu'i) yana tabbatar da ingancin marufi don kare mai canzawa da na'urorin haɗi.
- Tabbacin Inganci (Kira)- Ana kammala dubawa na gani na ƙarshe da lissafin kayan haɗi kafin shiryawa. Jerin tattarawa yayi daidai da ainihin abubuwan, kuma an haɗa cikakkun saitin takaddun fasaha na harshe biyu.
4.2 Shipping
Ikon cikakken tsari - akan lokaci, isarwa mai lafiya
- Daidaita Siga- Ana ƙarfafa abubuwan da ba su da rauni (mai canza famfo, na'urar taimakon matsa lamba, da sauransu) ana ƙarfafa ko jigilar su daban don tabbatar da yanayin wurin ya dace da jigilar kayayyaki.
- Ka'idojin Biyayya- Ayyukan jigilar kaya sun bi ƙa'idodin jigilar kayayyaki masu haɗari (lokacin da aka ware man transfoma a matsayin mai ƙonewa) da buƙatun sufuri na gida.
- Dogara (Gwaji)- An zaɓi ƙwararrun ƙwararrun ƙwararrun kayan aikin wutar lantarki; an shirya inshorar kaya; Ana ba da sa ido na ainihi.
- Tabbacin Inganci (Kira)– Kafin aikewa, ƙungiyoyin inganci da dabaru suna yin gwajin sau biyu na ƙarshe; Ana ajiye hotuna masu lodi. Ana ba da jagorar kwashe kayan aiki a kan kayan aiki don mahimman ayyukan ƙasashen waje.
05 Yanar Gizo da Takaitawa
An tsara wannan silsilar taswira mai ɗaure daDaidaita siga mai sarrafa aikace-aikacedaga jijiya zuwa jigilar kaya ta ƙarshe, cikakken cikawaIEEE Std C57.12.34-2022domin tsarin aminci daDOE 2016don ingantaccen makamashi.
- Tabbacin Amincewa- Cikakken tsarin tabbatarwa wanda ke rufe ƙira, masana'anta, da gwaji yana tabbatar da kwanciyar hankali na dogon lokaci koda a cikin yanayi mai tsanani.
- Tabbacin inganci- Gina kan tsarin kula da ingancin ingancin ISO 9001, sarrafa sarrafa maɓalli, da cikakken ganowa, muna isar da madaidaicin, masu canji masu inganci.
Mun himmatu wajen samarwainganci mai girma, babban abin dogaro, kuma daidai gwargwadomafita kayan aikin wutar lantarki don cibiyoyin rarraba, ayyukan makamashi mai sabuntawa, da aikace-aikacen masana'antu / kasuwanci.

Hot Tags: pad saka tafsirin masana'antun Amurka, masana'anta, mai kaya, farashi, farashi
You Might Also Like
1000 kVA Matsakaicin Kushin Gida Mai Canzawa-22.86 /...
75 KVA Matattu Mai Canjin Gaba-22.86 / 0.48 KV|Amurk...
300 KVA Matattu Masu Canjin gaba-12.47 / 0.208 KV|Ka...
1000 KVA Solar Duty Transformer-12.47 / 0.48 KV|Amur...
2000 KVA Bayonet Fuse Pad Mai Canzawa-13.8 / 0.48 KV...
750 KVA Kushin Haɓaka Farashin Canji-4.16 / 0.6 KV|K...
Aika Aikace-aikacen