Mai canzawa 1000kVA-13.8 / 0.6 KV|Amurka 2025
Yawan aiki: 1000 kVA
Ƙarfin wutar lantarki: 13.8D-0.6y/0.346 kV
Feature: tare da kama
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'anta da masu samar da taswira 1000kva{6}}13.8/0.6 kv|Amurka 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Aiki a natse, cikakkiyar kariya ta rufaffiyar - pad{1}}wanda aka ɗora tafsiri yana ɓoye aminci da dorewa a bayan bayyanarsa mara kyau.
01 Gabaɗaya
1.1 Bayanin Aikin
1000 kVA transformer 1000kVA an isar da shi zuwa Amurka a cikin 2025. Ƙarfin wutar lantarki na 1000kVA shine 1000 kVA tare da sanyaya KNAN. Babban ƙarfin lantarki shine 13.8D kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.6Y / 0.346 kV, sun kafa ƙungiyar vector na Dyn1.
Wannan kushin - da aka ɗora wutar lantarki shine1000 kVA, uku -tsari, naúrar ƙafa uku-gyare-gyare don ingantaccen aiki a cikin hanyoyin rarraba ƙasa. An tsara shi da amadauki{0}}tsarin ciyarwakumamatattu{0}} gini na gaba, yana tabbatar da amincin aiki da ci gaba da sabis ta hanyar rage ɓoyayyen sassa masu rai da ba da damar haɗin gwiwar tsarin sassauƙa. Transformer yana amfaniFR3 man kayan lambu, Samar da ingantaccen tsaro na wuta, haɓakar haɓakar haɓakar halittu, da ingantaccen rayuwar rufi idan aka kwatanta da mai na ma'adinai na al'ada. GanawaMatsayin ingancin DOE, wannan rukunin yana ba da asarar ƙananan hasara da tattalin arzikin aiki mai girma. masana'anta ce{1}} sanye da shimasu kamun kaidon hadedde overvoltage kariya, kuma gama da mfoda -fararen rufi (RAL 9003)yadi wanda ya haɗu da juriya na lalata tare da tsaftataccen yanayin tsaka-tsakin kyan gani wanda ya dace da aikace-aikacen zama ko na kasuwanci.
1.2 Ƙayyadaddun Fasaha
1000 kVA taswira 1000kVA takamaiman nau'in da takardar bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2025
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
IEEE Std C57.12.34-2022 DOE 2016
|
|
Ƙarfin Ƙarfi
1000 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
KNAN
|
|
Babban Voltage
13.8D kV
|
|
Na biyu Voltage
0.6y/0.346 kV
|
|
Abubuwan Iska
Aluminum
|
|
Ƙungiyar Vector
Dyn1
|
|
Impedance
5.75%
|
|
inganci
99.43%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
1.3 kW
|
|
Akan Rasa Load
6.94 kW
|
1.3 Zane
1000 kVA mai canzawa 1000kVA zane da girman zane.
![]() |
![]() |
02 Masana'antu
2.1 Core Design & Performance
karban a3-cibin ƙafa ukuwanda aka yi da babban yuwuwar yuwuwa, ƙananan{1}}asara silikon karfe takardar (ƙididdigar mitar 60Hz). Ma'auni na babu{4}} load halin yanzu shine kawai 0.54%, yana tabbatar da ƙarancin-asara da babban{7}} aiki mai inganci na da'irar maganadisu.
Multi{0}}Tabbacin girma
- Daidaita Siga: Ƙirar ƙira ta yi daidai da 1000kVA da aka ƙididdige iya aiki da KNAN kai -yanayin sanyaya, saduwa da buƙatun hawan zafin jiki (matsakaicin ƙasa ko daidai da digiri 65, mafi zafi{3}} tabo Kasa ko daidai da digiri 80).
- Daidaitaccen Biyayya: Yana biye da IEEE Std C57.12.34-2022 don ƙirar da'irar maganadisu da sarrafa asarar.
- Garanti mai inganci: Raw kayan 100% duba; lamination tare da madaidaicin kayan aiki; Gwajin aikin maganadisu kafin - ga kowane cibiya; samfuran da ba - an ƙi su a farkon tsari.


2.2 Tsarin iska
Yana amfani da inganci mai girma{0}aluminum windingstare da ± 2 * 2.5% babu - ana canza matsi. Adadin rashin daidaituwar juriya da aka auna shine 0.13% (HV) / 2.43% (LV), kuma karkacewar rabon ƙarfin lantarki shine -0.01% ~ 0.06%, tare da ingantaccen daidaito da daidaiton ƙarfin lantarki.
Garanti mai inganci: Tsarin iska na CNC; gwajin gwaji / juriya bayan iska; wuce juriya na matsa lamba da gwajin hawan zafin jiki ba tare da raguwa ko zafi ba.

2.3 Tanko
Anyi shi da inganci{0}carbon karfetare da tsarin da aka rufe da murfin da aka kulle, sanye take da ƙwanƙwasa ɗagawa da jacking pads don sauƙin sarrafawa. Fuskar da aka fesa tare da RAL 9003 farin foda don juriya na lalata; gwada 24h a 20kPa tare dababu yabo, kyakkyawan aikin rufewa.
Multi{0}}Tabbacin girma
Aikace-aikacen Ayyuka: Rufewa da ƙirƙira ƙirar lalata don buɗe waje{1}} shigarwar iska (tsayin ƙasa da ko daidai da 1000m), wanda ya dace da abubuwan more rayuwa na birni da rarraba wutar lantarki na masana'antu.
Daidaita Siga: Girman tanki/ƙarfin tsari cikakke yayi daidai da adadin cika mai na FR3 da jimlar nauyi mai canzawa (babu zubewar mai ko haɗarin lalacewa).
Garanti mai inganci: Daidaitaccen machining don lankwasawa / walda; gwaji mara lahani don walda; pickling da phosphating kafin fesa; ware HV/LV compartments don mafi girma rufi aminci.


2.4 Taron Karshe
Masu karɓamadauki abincizane; Dakin HV tare da 6 keɓaɓɓen keɓaɓɓen bushings (200A), rukunin LV tare da bushings ɗin guduro 3. Daidaitaccen tsari: fuses bayonet 3, CLFs 3, 1 huɗu{7}matsayi mai ɗaukar nauyi mai canzawa, 1 babu{9}}mai sauya famfo, da cikakkun kayan aikin sa ido (ma'aunin zafin mai, ma'aunin matakin, da sauransu).3 sets na masu kama walƙiyadon haɗakar da wutar lantarki, kariya da saka idanu.
Multi{0}}Tabbacin girma
- Daidaita Siga: Ƙididdigar halin yanzu / ƙarfin lantarki na duk na'urorin haɗi sun dace da ma'auni na asali; Matsayin kama walƙiya ya dace da mai canzawa BIL (30kV HV / 95kV LV).
- Daidaitaccen Biyayya: Tsarin taro, wayoyi da ƙirar ƙirar ƙasa (1 kowane a cikin HV / LV) bi IEEE Std C57.12.34-2022.
- Garanti mai inganci: Daidaitaccen tsarin taro; gwajin ci gaba / gwaji bayan wayoyi; babu{0}}gwajin lodi ga injin gabaɗaya; cikakken - duba tsari don tabbatar da daidaiton taro.


03 Gwaji
1. Daidaitaccen Biyayya
Tsarin gwaji da aka tsara daidai daIEEE Std C57.12.34-2022; An gwada ingancin makamashi kowaneDOE 2016daidaitattun (duk sakamakon ya cika kuma ya wuce buƙatu).
2. Babban Sakamako na Gwajin (Aunawa Ma'auni)
|
Gwajin Abun |
Madaidaicin Ƙimar / Garanti |
Ƙimar Aunawa |
Kammalawa |
|
Rashin Ma'auni Juriya |
Kasa da ko daidai da 5% (masana'antu na al'ada) |
0.13% (HV) / 2.43% (LV) |
Wuce |
|
Rashin Wutar Lantarki |
Kasa da ko daidai da 0.5% (ƙimar famfo) |
-0.01% ~ 0.06% |
Wuce |
|
A'a -Asar lodi (digiri 20) |
Kasa da ko daidai da 1.3kW (+10% haƙuri) |
1.214 kW |
Wuce |
|
Babu -Lokaci Yanzu |
An yi la'akari da ƙimar ƙima |
0.54% |
Wuce |
|
Asara Load (digiri 85) |
Kasa da ko daidai da 6.94kW (+6% haƙuri) |
6.502 kW |
Wuce |
|
Short -Tsarin kewayawa |
± 7.5% haƙuri (5.75%) |
5.74% |
Wuce |
|
Gabaɗaya Inganci |
Yafi ko daidaita 99.43% (DOE 2016) |
99.47% |
Wuce |
|
Gwajin Karfin Wutar Lantarki |
34kV (HV)/10kV (LV), 60s babu rushewa |
Babu rushewar wutar lantarki |
Wuce |
|
Gwajin Wutar Lantarki da aka Ƙarfafa |
2Ur, 150Hz, 48s babu rushewa |
Babu rushewar wutar lantarki |
Wuce |
|
Gwajin Leaka |
20kPa, 24h babu yabo |
Babu yabo & babu lalacewa |
Wuce |
|
Juriya na Insulation |
An yi la'akari da ƙimar ƙima |
1.87GΩ (HV -LV zuwa GND);2.54GΩ (LV-HV zuwa GND);1.26GΩ (HV&LV zuwa GND) |
Wuce |


04 Shiryawa da jigilar kaya
4.1 Shiryawa

Layer na ciki: Bakin jakar filastik aluminum, wanda ya ƙunshi desiccant, don kare danshi da tsatsa;
Layer na waje: Akwatin katako, tare da alamar cokali mai yatsa da tsakiyar alamar nauyi da aka fesa akansa;
Kayan kariya na gefen: kumfa, filastik ko kwali masu gadi don hana lalacewa yayin sufuri;
Ya dace da sufurin teku da kuma dogon lokaci{0} ajiyar waje.
4.2 Shipping
Marufi na waje na akwatin katako yana da alama a fili:
Forklift aiki matsayi
Cibiyar nauyi matsayi
An yi dalla-dalla ma'aunin nauyi, nauyin mai da girman na'urar ta atomatik a cikin zane-zane.
Ana iya ba da sanarwar fakitin fitarwa da lissafin tattarawa.

05 Yanar Gizo da Takaitawa
Wannan na'urar taswira ce 1000kVA wacce ta cika cika ka'idodin IEEE da DOE, yana da ingantaccen aiki na gaske idan aka kwatanta da ƙimar sa, yana amfani da mai na FR3 mai dacewa da muhalli, kuma yana da damar kariyar walƙiya. Ya wuce duk gwaje-gwaje na yau da kullun, tare da ingantaccen sakamakon gwaji, tsarin sarrafawa mai sarrafawa, daidaitaccen marufi da sufuri, kuma ya dace da ayyukan rarraba ƙasa a kasuwar Arewacin Amurka.

Hot Tags: transformer 1000kVA, manufacturer, maroki, farashin, farashi
You Might Also Like
750 kVA Kushin Haɗa Mai Canjawa-13.2 / 0.48 kV|Amurk...
750 kVA Kushin Haɓaka Mai Canja wurin Mai amfani-34....
Mai canzawa 1000kVA-25/0.6 kV|Kanada 2024
500 KVA Green Canjin Canjin Lantarki Akwatin-23.9 / ...
750 KVA Kushin Haɓaka Madaidaicin Madaidaicin Ciyarw...
1000 KVA Kushin Haɓaka Akwatin Canji-13.8 / 0.48 KV|...
Aika Aikace-aikacen