1000 KVA Custom Loop Feed Electric Pad Dutsen Mai Wuta-25/0.6 KV|Kanada 2025
Yawan aiki: 1000kVA
Wutar lantarki: 25/0.6kV
Siffar: Utility{0}}Mai Tsare-tsare
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin mafi amintattun masana'antun da masu samar da 1000 kva al'ada madauki feed lantarki kushin da aka ɗora wutar lantarki{6}}25/0.6 kv|kanada 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

1000 kVA al'ada madauki feed lantarki kushin da aka ɗora tasfoma - mai amfani{2}} ƙira mai dacewa don abin dogaro, mai girma{3}} iya rarrabawa tare da sauƙin shigarwa filin
01 Gabaɗaya
1.1 Bayanin Aikin
An ƙididdige shi a 1000 kVA, 60 Hz, wannan al'ada madauki na ciyar da kushin lantarki wanda aka ɗora taswira yana amfani da sanyaya mai na ONAN. Na farko shine 25 kV tare da 150 kV BIL, yana ba da haɗin kai mai ƙarfi don cibiyoyin rarraba kayan aiki. Babban bangaren wutar lantarki- yana da masu haɗin haɗin da za a iya raba su, yana barin matattu{7}}aiki na gaba da shigarwa cikin sauƙi. A gefen na biyu, yana sauka zuwa 600Y/347 V tare da 30kV BIL, wanda aka ƙera don haɗawa da su cikin masu ciyarwa. Hudu - tashoshi na ramuka tare da ƙasa suna tabbatar da ƙarfin injina da ingantaccen ƙarfin ɗauka na yanzu. Ƙungiyar vector Dyn1 tana rage jituwa sau uku kuma tana ɗaukar rashin daidaituwa daidai gwargwado{16}} ƙalubalen gama gari a tsarin rarraba jama'a. Wannan al'ada madauki ciyarwar lantarki kushin da aka ɗora tasfoma yana misalta Utility{18}} Tsare-tsare, wanda aka gina don kwanciyar hankali na cibiyar sadarwa da amincin aiki.
1.2 Ƙayyadaddun Fasaha
1000kVA uku lokaci kushin saka gidan wuta ƙayyadaddun bayanai da takardar bayanai
|
Isarwa zuwa
Kanada
|
|
Shekara
2025
|
|
Nau'in
Uku fanni kushin Dutsen transformer
|
|
Daidaitawa
CSA C{0}:21
|
|
Ƙarfin Ƙarfi
1000 KVA
|
|
Yawanci
60HZ
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Mataki
Uku
|
|
Nau'in Sanyi
ONAN
|
|
Liquid insulant
Ma'adinai mai
|
|
Babban Voltage
25 kv
|
|
Na biyu Voltage
0.6 kV
|
|
Ƙungiyar Vector
Dyn1
|
|
Abubuwan Iska
Aluminum
|
|
Impedance
5.75%
|
|
inganci
99.06 %
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
1.85 kW
|
|
Akan Rasa Load
12.8 kW
|
|
Na'urorin haɗi
Daidaitaccen Kanfigareshan
|
1.3 Zane
1000kVA uku lokaci kushin saka transformer zane da sunan farantin
![]() |
![]() |
02 Zane-zanen Sadarwar Rarraba Mai Amfani
2.1 Tsarin Wutar Lantarki
An ƙididdige shi a 1000 kVA, 60 Hz, wannan tafsiri yana amfani da sanyaya mai na ONAN. Na farko shine 25 kV tare da 150 kV BIL, yana ba da haɗin kai mai ƙarfi don cibiyoyin rarraba kayan aiki. Babban bangaren wutar lantarki- yana da masu haɗin haɗin da za a iya raba su, yana barin matattu{7}}aiki na gaba da shigarwa cikin sauƙi.
A mataki na biyu, yana sauka zuwa 600Y/347 V tare da 30kV BIL, wanda aka ƙera don haɗawa cikin masu ciyarwa. Hudu -Rami tashoshi tare da ƙasa yana tabbatar da ƙarfin injina da ingantaccen ƙarfin ɗauka na yanzu.
Ƙungiyar vector Dyn1 tana rage jituwa sau uku kuma tana ɗaukar rashin daidaituwa daidai gwargwado{1}} ƙalubalen gama gari a tsarin rarraba jama'a. Wannan Haqiqa Utility -Mai Tsare-tsare ne, an gina shi don kwanciyar hankali da amincin aiki.



2.2 Aiki & Kariya
Don tallafawa cibiyoyin rarraba madaidaicin mai amfani, injin na'ura yana sanye da maɓalli guda huɗu{0}}madaidaicin madaidaicin matsayi, yana ba da damar keɓancewa da keɓancewa ba tare da katse sabis ɗin zuwa manyan lodi ba. A kashe -Mai canjin kewayawa (NLTC) yana samar da kewayon ±2 × 2.5% na taɓawa, yana ba da damar ƙa'idar wutar lantarki don dacewa da yanayin ciyarwa.
An haɗa cikakken saitin kayan amfani{0}}kariyar daraja da na'urorin saka idanu:






Waɗannan fasalulluka suna tabbatar da amintaccen aiki, kariyar kuskure, da sauƙaƙan tabbatarwa a duk rayuwar sabis na taswira. A matsayin madauki na al'ada na ciyar da kushin lantarki wanda aka ɗora taswira, yana goyan bayan aikin hanyar sadarwa mai sassauƙa yayin saduwa da ƙa'idodin aikin kayan aiki na zamani.
2.3 Inganci & Asara
An ƙera shi daidai da CSA C802.1, wannan al'ada madauki na ciyar da kushin wutar lantarki da aka ɗora taswira ya sami mafi ƙarancin inganci na 99.06%. Ana sarrafa aikin hasara daidai, ba tare da asarar - na 1.85 kW kawai da kuma asara mai nauyin 12.8 kW a kan iyawar da aka ƙididdige shi, yana rage yawan amfani da makamashi yayin duka rago da yanayin aiki.
Mai taswira yana da maƙasudin 5.75%, wanda aka tabbatar a ƙimar ƙimar 100% kuma an gyara shi zuwa digiri 85, yana ba da ƙayyadaddun kuskure na yanzu da tabbatar da kwanciyar hankali a layi daya a cikin hanyoyin rarraba kayan amfani.
Wannan ƙaƙƙarfan ƙira da ƙarancin ƙira{1} asara yana rage tsawon lokaci{2} farashin aiki kuma yana goyan bayan dabarun sarrafa kadarorin rayuwa ta hanyar isar da ingantaccen aiki da rage jimillar farashin mallaka.
03 Gwaji


04 Shiryawa da sufuri


05 Yanar Gizo da Takaitawa
Wannan 1000 kVA uku -kushin lokaci - wanda aka ɗora tafsiri an ƙera shi musamman don cibiyoyin rarraba kayan amfanin jama'a, yana tallafawa ingantaccen isar da wutar lantarki zuwa gundumomin kasuwanci, abubuwan more rayuwa na birni, da gauraye{3}} wuraren sabis na kaya. Haɗin sa na ƙirar lantarki mai ƙarfi, ingantaccen inganci, cikakkiyar kariya, da ingancin masana'anta ya sa ya zama abin dogaro ga tsarin wutar lantarki na zamani.
Hot Tags: al'ada madauki feed lantarki kushin saka transformer, ma'aikata, maroki, farashin, farashi
You Might Also Like
750 kVA Liquid Cika Masu Canji-12.47 / 0.6 kV|Amurka...
500kVA Kushin Dutsen Mai Canjawa-14.4 / 0.208 kV|Amu...
1500 kVA Kushin Haɓaka Farashin Canji-23.9 / 0.416 K...
500 kVA Utility Pad Hawan Canji-24 / 0.48 kV|Amurka ...
75 KVA Matattu Mai Canjin Gaba-22.86 / 0.48 KV|Amurk...
500 KVA Radial Feed Transformer-12.47*4.16/0.6 KV|Ka...
Aika Aikace-aikacen