5 MVA Model Railway Transformer-66 / 1.22 KV|Afirka ta Kudu 2025

5 MVA Model Railway Transformer-66 / 1.22 KV|Afirka ta Kudu 2025

Ƙasa: Afirka ta Kudu 2025
Yawan aiki: 5000 kVA
Ƙarfin wutar lantarki: 66/1.22 kV
Siffar: tare da radiyo mai zafi{0}} tsoma galvanized
Aika Aikace-aikacen

Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'antun da masu samar da na'ura mai ɗaukar hoto na 5 mva model -66/1.22 kv|Afirka ta Kudu 2025 a China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

 

model railway transformer

Mai Canjawa: Ƙarfafa Motsi na gaba

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

An kai 5 MVA traction transfomer zuwa Afirka ta Kudu a cikin 2025. Ƙarfin wutar lantarkin shine 5000 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 66 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙarfin lantarki na biyu shine 1.22 kV, sun kafa ƙungiyar vector na Y/d± 15 digiri d11.

An ƙera shi da tsari don ɗorewa, ƙirar tashar jirgin ƙasa tana ɗaukar tsari na numfashi kyauta tare da na'urar numfashi ta siliki don kula da ingancin mai, yayin da murfin tanki ɗin sa yana haɓaka aikin rufewa. The galvanized radiators ba wai kawai samar da ingantaccen zafi mai zafi ba amma kuma suna ba da kyakkyawan juriya na lalata, suna daidaita hanyar sanyaya ONAN (Oil Natural Air Natural) wanda ke ba da garantin ingantaccen aiki a ƙarƙashin ci gaba da kaya. Dukansu manyan iskar wutar lantarki{3} da ƙananan - ana ƙera su ne daga jan ƙarfe, suna isar da ingantacciyar wutar lantarki, ƙarancin ƙarancin kuzari, da kwanciyar hankali na tsawon lokaci-.

Dangane da aiki, na'urar na'ura tana nuna inganci mai ban sha'awa{0}} yana kaiwa zuwa 99.37% a 1.0 power factor da 99.22% a 0.8 power factor (a 75 digiri ){6}}tare da ƙarancin baƙin ƙarfe (6000 Watts) da cikakken-arfafa nauyin nauyin digiri na jan karfe (25400 Watts) 31400 watts. Cikakkar nauyin nauyinsa yana tsaye a 8.15% (reactance: 8.13%), kuma an inganta tsarin wutar lantarki zuwa 0.51% (1.0 PF) da 5.3% (0.8 PF) a digiri 75, yana tabbatar da sarrafa wutar lantarki daidai. Tare da hawan zafin jiki na iska mai iyaka zuwa digiri 50 kuma saman zafin mai ya tashi zuwa digiri 45, mai canzawa yadda ya kamata yana rage damuwa na thermal, yana tsawaita rayuwar sabis ɗin sa da saduwa da ƙaƙƙarfan buƙatun tsarin samar da wutar lantarki don aminci, inganci, da daidaito.

 

1.2 Ƙayyadaddun Fasaha

5000kVA gogayya mai canzawa nau'in ƙayyadaddun ƙayyadaddun bayanai da takaddar bayanai

Isarwa zuwa
Afirka ta Kudu
Shekara
2025
Nau'in
gogayya ta canza
Daidaitawa
Saukewa: IEC60076
Ƙarfin Ƙarfi
5000 kVA
Yawanci
50HZ
Mataki
3
Nau'in Sanyi
ONAN
Babban Voltage
66 kv
Na biyu Voltage
2* 1.22+1.22 kV
Abubuwan Iska
Copper
Matsala ta kusurwa
Y/d±15 digiri d11
Impedance
8%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
6 kW
Akan Rasa Load
25.4 kW

 

1.3 Zane

5000 kVA juzu'in juzu'in zane da girman zane.

model railway transformer diagram model railway transformer nameplate

 

 

02 Masana'antu

2.1 Mai Kula da Mai

Oil Conservator

Mai tanadin mai wani tanki ne da aka rufe da aka haɗa da babban tanki, wanda aka ƙera shi don ɗaukar haɓakar yanayi da ƙanƙantar mai saboda canjin yanayin zafi yayin aiki. Ta hanyar kiyaye matakin mai akai-akai da rage yawan iskar mai zuwa iska, yana hana iskar shaka da danshi yadda ya kamata. Wannan muhimmin aikin yana tabbatar da dogon lokaci{2} kwanciyar hankali na kaddarorin dielectric na mai, yana kiyaye rufin ciki, kuma yana haɓaka cikakken aminci da rayuwar sabis na taswira.

 

2.2 Mai Nunin Zazzabi Mai Iska

Nunin zafin jiki na iska (WTI) na'urar sa ido ce mai mahimmanci don taswirar gogayya. Yana kwatanta yanayin zafi mafi zafi a cikin iskar iska, wanda ya fi yadda aka auna saman sama{1}} zafin mai. Yin amfani da kwan fitila mai firikwensin a cikin mai da madaidaicin nau'in dumama da aka haɗa ta bututun capillary, WTI daidai yana nuna ainihin yanayin zafi na iska. Yana ba da mahimman karatun zafin jiki kuma yawanci yana haifar da ƙararrawa kuma, idan ya cancanta, umarnin tafiya don hana lalatawar rufi da kuma tabbatar da injin na'urar na'ura tana aiki da dogaro a cikin amintaccen iyakar zafinta.

Winding Temperature Indicator

 

2.3 Numfashi

Breather

Mai shayarwa, ko mai shayar da danshi, shine na'urar kariya mai mahimmanci don taswira. An ɗora shi akan bututun iska, yana ɗauke da cajin silica gel desiccant. Yayin da na’urar taranfoma ke shaka saboda fadada man fetur da takurewar mai, duk iskar da ke shigowa sai ta wannan numfashin. Gel na silica yana shayar da danshi daga iska, yana hana shi shiga ma'aunin mai da kuma lalata mai. Wannan muhimmin aikin yana kare tsarin rufewar ciki na taransfoma daga lalacewa, yana tabbatar da ƙarfin wutar lantarki da tsawon lokaci{4}} amintaccen aiki.

 

2.4 Akwatin Tasha

Akwatin tasha wani amintaccen shinge ne da aka ɗora akan tankin mai ɗaukar wuta, yana gina hanyoyin haɗin wutar lantarki na waje don maɗaukakin wutar lantarki da ƙaramar iskar wutar lantarki. Yana ba da hanyar sadarwa mai kariya inda keɓaɓɓen bushings ke ƙarewa, kuma ana haɗa igiyoyi daga tsarin wutar lantarki na layin dogo. Ayyukansa na farko shine tabbatar da aminci, amintaccen haɗin wutar lantarki, kare tashoshi daga abubuwan muhalli kamar danshi da ƙura, da bayar da shingen tsaro masu mahimmanci ga ma'aikata yayin aiki da kiyayewa, ta haka ne ke tabbatar da amincin wutar lantarki gabaɗaya da amincin na'urar.

Terminal Box

 

2.5 Zafi -Dip Galvanized Radiator

Hot-Dip Galvanized Radiator

Radiator mai zafi{0}} tsoma galvanized shine ɓangarorin kwantar da hankali na ƙirar hanyar jirgin ƙasa. Ya ƙunshi jerin filaye ko bututu waɗanda ke ba da babban yanki don watsar da zafi daga mai da ke rufewa zuwa cikin iska mai kewaye. Maɓalli mai mahimmanci shine samansa mai zafi{3}} tsoma galvanized karfe, wanda ke ba da juriya na musamman na lalata. Wannan ƙaƙƙarfan kariyar tana da mahimmanci don tabbatar da ingantaccen tsari na dogon lokaci da ingantacciyar hanyar canja wurin zafi, musamman lokacin da taswirar ke aiki a cikin yanayi mai zafi ko ɗanɗano, ta haka yana ba da garantin ingantaccen aiki mai inganci.

 

2.6 Bushewar Sashe Mai Aiki

Bushewar ɓangaren aiki muhimmin tsari ne na masana'anta don core transformer{0}}da{1}}garuwa (bangare mai aiki). Ya ƙunshi cire saura danshi daga rufin cellulose (takarda da allo) da ainihin laminations ta hanyar dumama sarrafawa a ƙarƙashin babban injin. Wannan ƙaƙƙarfan tsari yana tabbatar da rufin yana samun ƙarancin ɗanɗano mai ƙanƙan da kai, wanda ke da mahimmanci don kafa ƙarfin lantarki mai ƙarfi, hana fita juzu'i, da ba da garantin doguwar amincin na'urar ta atomatik da tsawon lokacin aiki a ƙarƙashin yanayin layin dogo.

Active Part Drying

 

 

03 Gwaji

The Full-Wave Lightning Impulse Test is a rigorous high-voltage type test applied to the line terminals of a traction transformer. Yana kwaikwayi mummunan yajin walƙiya ta amfani da daidaitaccen ƙarfin ƙarfin lantarki na 1.2/50 µs. Wannan gwajin yana tabbatar da inganci da ƙarfi na babban tsarin rufewa, musamman iska da bushe-bushe, a ƙarƙashin matsanancin yanayin wuce gona da iri. Cin wannan gwajin yana da mahimmanci don tabbatar da ikon taransfoma don jure haƙiƙanin walƙiya na duniya, tabbatar da ingantaccen tsaro ga tsarin samar da wutar lantarki na layin dogo.

Full-Wave Lightning Impulse Test
voltage impulse

 

 

04 Shiryawa da jigilar kaya

4.1 Shiryawa

model railway transformer packing
model railway transformer packaging

 

4.2 Shipping

model railway transformer shipping
model railway transformer transportation

 

 

05 Yanar Gizo da Takaitawa

A SCOTECH, samfurin mu na tashar jirgin ƙasa an ƙera shi sosai kuma an ƙera shi don sadar da aiki mara kyau, ingantaccen aminci da tsawaita rayuwar sabis. An keɓance su da kyau don biyan ƙaƙƙarfan buƙatun aiki na manyan hanyoyin jiragen ƙasa masu sauri, metros na birni da sauran ingantattun hanyoyin jigilar dogo. Rike da ƙa'idodin ƙirƙira fasaha, ingantaccen kulawar inganci da abokin ciniki{3}}ƙauna, muna ƙoƙari mu zama amintaccen abokin tarayya don hanyoyin samar da wutar lantarki. Muna sa ran gina dogon lokaci{5} nasara - nasara tare da abokan cinikin duniya, tare da haɓaka ingantacciyar inganci da ci gaba mai dorewa na masana'antar zirga-zirgar jiragen ƙasa.

model railway transformer manufacturer

 

Hot Tags: model jirgin kasa transformer, manufacturer, maroki, farashin, farashi