5 MVA Railway Transformer-44 / 6.6 kV|Afirka ta Kudu 2025
Yawan aiki: 5000 kVA
Ƙarfin wutar lantarki: 44/6.6 kV
Siffar: tare da radiyo mai zafi{0}} tsoma galvanized

Babban -Masu Canjin Ayyukan Aiki - Injiniyoyi don Sauri & Tsaro!
01 Gabaɗaya
1.1 Bayanin Aikin
5 MVA traction transformer an isar da shi zuwa Kanada a cikin 2025. Ƙarfin wutar lantarkin shine 5000 kVA tare da sanyaya ONAN. Babban ƙarfin lantarki shine 44 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙarfin lantarki na biyu shine 6.6 kV, sun kafa ƙungiyar vector na Dyn11.
An ƙera wannan na'ura mai ɗaukar wutar lantarki don biyan buƙatun samar da wutar lantarki na tashoshin watsa wutar lantarki, wanda ke ba da wutar lantarki don tsarin layin watsa 11 kV da 6.6 kV. Yana da ƙayyadaddun ƙirar ƙira mai kyau {{3} tare da takamaiman buƙatun na'urorin haɗi, gami da babu - na'ura mai canzawa - mai canzawa, radiyo masu zafi - dip galvanized radiators, da bawuloli daban-daban da na'urorin sa ido. An gina tanki mai canzawa tare da faranti na ƙarfe (Mafi girma ko daidai da 6mm don tanki, 16mm don farantin ƙasa) kuma yana da tsarin ma'ana na (bushings), sanduna, da tashoshi (tare da ƙayyadaddun diamita don haɗin kai daban-daban). An ba da la'akari na musamman ga juriya mai jituwa, ƙarfin injina na iska, da ƙirar gurɓatawa (tare da ƙayyadaddun tsarin launi da ƙaƙƙarfan ƙanƙara mai juriya). An ƙirƙira shi don tabbatar da ingantaccen aiki, ingantaccen watsar da zafi, da kulawa mai dacewa, yana taka muhimmiyar rawa a cikin tsarin samar da wutar lantarki.
1.2 Ƙayyadaddun Fasaha
75 kVA iyakacin duniya saka na'ura mai canzawa nau'in bayani dalla-dalla da takardar bayanai
|
Isarwa zuwa
Afirka ta Kudu
|
|
Shekara
2025
|
|
Nau'in
Pole mounted transformer
|
|
Daidaitawa
Saukewa: IEC60076
|
|
Ƙarfin Ƙarfi
5000 kVA
|
|
Yawanci
50HZ
|
|
Mataki
3
|
|
Nau'in Sanyi
ONAN
|
|
Babban Voltage
44 kv
|
|
Na biyu Voltage
6.6 kv
|
|
Abubuwan Iska
Copper
|
|
Matsala ta kusurwa
Domin 11
|
|
Impedance
7%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
4.54 kW
|
|
Babu Asara Load
35 kW
|
1.3 Zane
5000 kVA juzu'in juzu'in zane da girman zane.



02 Masana'antu
2.1 Kori
Na'urar tawul ɗin tawul ɗin tana ɗaukar nau'i-nau'i guda uku{0}sashi na uku{1}}, an gina ta daga siraran siraren ƙarfe na silicon (0.23-0.35mm) tare da rufin rufi don rage yawan asarar da ake samu a halin yanzu. Daidaitaccen -wanda aka jera tare da haɗin gwiwar ƙafar ƙafa, ƙirar tana tabbatar da rashin ƙarancin nauyi{7}}, daidaitaccen rarrabawar ruwa, da ƙarfin injina don jure girgizar layin dogo. Karamin tsarin sa na gaba guda uku - yana inganta ingancin maganadisu yayin da yake rage nauyi, yana mai da shi manufa don manyan hanyoyin sarrafa wutar lantarki.

2.2 Guda

The traction transformer yana amfani da ci gaba da iska don ingantaccen aiki a cikin buƙatar aikace-aikacen layin dogo. Wannan ƙwaƙƙwaran ƙira yana fasalta makullin faifan diski waɗanda ke ba da ƙarfin injina na musamman don jure rawar jiki da gajeriyar runduna ta kewayawa, tare da kiyaye ingantattun halayen lantarki. Matsalolin mai na iska a tsaye yana tabbatar da ingantacciyar sanyaya, kuma ginin madugun sa yana rage asara a halin yanzu. Tsarin diski mai ci gaba yana ba da ingantaccen ƙarfin ƙarfin juriya da rarrabuwar zafin jiki iri ɗaya, yana mai da shi manufa don sarrafa yawancin bambance-bambancen kaya da ke cikin tsarin wutar lantarki. Wannan ƙaƙƙarfan bayani mai jujjuyawar iska yana haɗawa da aminci tare da babban aikin lantarki da thermal.
2.3 Tanko
The traction transformer yana da wani tanki fenti mai launin toka- mai launin fari (tankin mai), yana tabbatar da bayyananniyar ganewar gani. An gina tankin da zafi tsoma galvanized radiyo masu cirewa don ingantacciyar juriyar lalata da ingantaccen watsawar zafi.
Don samun damar kiyayewa, murfin dubawa ko ramukan magudanar ruwa ana ɗaure su tare da kusoshi da hatimin gasket don hana zubar mai. Kowane murfin yana sanye da ingantattun hannayen ɗagawa don amintaccen cirewa yayin hidima.
Wannan ƙaƙƙarfan ƙira yana tabbatar da dorewa, juriya na yanayi, da sauƙin kulawa a cikin buƙatun yanayin layin dogo.

2.4 Taron Karshe

1. Tauraron Iska:Zamewa kafin -Ƙaramar LV (ƙananan{1}}ƙarfin wutar lantarki) da HV (high{2}}ƙarfin wutar lantarki) zuwa kan ainihin, yana tabbatar da daidaita daidaitattun abubuwan da suka shafi insulation (spacers, blocks) da kuma ƙara ƙarfin iska.
2. Haɗin Wutar Lantarki:Yi haɗin walda ko kulle-kulle don karkatar da kai, shigar da masu canza famfo, rufe haɗin gwiwa, da kiyaye duk haɗin gwiwa.
3. Core -Bushewar Naɗi:Sanya sashin da aka haɗa a cikin tanda mai bushewa don bushewar iska mai zafi{0}} bushewar iska don cire damshi, sannan tabbatar da juriya na rufi ya dace da ma'auni.
4. Majalisar Tankoki:Ɗaga busasshen mai aiki a cikin tanki, daidaita kuma a tsare shi, sa'an nan kuma kushe kuma ku rufe sashin ƙananan tanki.
5. Shigar Na'ura:Dutsen bushings, ma'ajin ajiya, bawul ɗin taimako na matsa lamba, ma'aunin zafin jiki, relay Buchholz, da sauran na'urorin haɗi, haɗa bututun da da'irori na sa ido.
6. Ciko Mai & Rufewa:Yi cikakken man mai zuwa ƙayyadadden matakin, gudanar da gwaje-gwajen zubewa
03 Gwaji
1. Auna narkar da iskar gas a cikin dielectric ruwa daga kowane keɓaɓɓen sashin mai ban da juzu'in sauyawa
2. Ma'auni na ƙarfin lantarki da kuma duba ƙaurawar lokaci
3. Ma'auni na juriya na iska
4. Aunawa Tsakanin Tsakanin Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwaƙwalwa na Ƙaƙwalwa .
5. Ƙayyadaddun abubuwan da ake iya ɗauka zuwa ƙasa da tsakanin windings
6. Gwajin Karfin Wutar Lantarki (AV)
7. Auna A'a - lodin hasara da na yanzu
8. Gwajin Juriya da Ƙarfin Wutar Lantarki
9. Auna Gajeren -Cikin Tasirin kewayawa da Rasa Load
10. Auna narkar da iskar gas a cikin dielectric ruwa daga kowane raba mai daki sai mai karkata canji sashi.
11. Gwajin Leak Tare da Matsi Don Ruwan Ruwa{1}}Masu Canja-Tsarki (Gwajin Tsattsauran ra'ayi)


04 Shiryawa da jigilar kaya
4.1 Shiryawa
Ana saka taransfoma cikin amintaccen rami mai ƙarfi ta katako ta amfani da santsi ko madauri na ƙarfe, tare da sassa masu rauni kamar bushings ɗin da aka nannade cikin firgita{0}}abin sha. Tankin ko dai man -cike ko kuma cike da busasshiyar iska/nitrogen, kuma akwatun an lullube shi da danshi{3}}fim mai hujja kuma an rufe shi da tef mai hana ruwa. Tsarin katako mai ƙarfi yana fasalta ramukan forklift / ɗagawa, ƙarfafa bandeji na ƙarfe, da murfin ruwan sama.
Alamomi na waje sun haɗa da nauyi, girma, alamomin kulawa, da alamun haɗari, yayin da takaddun ciki (jerin tattarawa, litattafai, rahotannin gwaji) ana adana su a cikin jaka mai hana ruwa.

4.2 Shipping

Ana loda tiransfomar a kan wata babbar mota mai daki sannan a kai ta tashar jiragen ruwa. Don sharuɗɗan CIF, mai siyarwa yana ɗaukar jigilar kaya na teku, gami da yin ajiyar jirgin ruwa mai dacewa tare da daidaitawa mai dacewa (misali, murɗa makulli don kwantena ko lallashewa don karyewa). Ana ajiye akwati na katako don guje wa bayyanar danshi, tare da alamun girgiza / girgiza. Inshora yana ɗaukar haɗarin ruwa (Duk Risks na ICC Clause A). Bayan isowa tashar jiragen ruwa na Durban, ana sauke kayan ta hanyar amfani da cranes na tashar jiragen ruwa, ana share su ta hanyar kwastan (mai kaya yana shirya takaddun fitarwa; mai siye yana sarrafa izinin shigo da kaya), kuma a kai shi zuwa takamaiman wurin da mai wakiltan ya ke. Ana iya buƙatar tireloli na musamman don manyan raka'a.
05 Yanar Gizo da Takaitawa
A matsayin ginshiƙin ginshiƙan layin dogo da tsarin wutar lantarki, na'urorin wutar lantarki na mu suna isar da amintacce, inganci, da daidaitawa ga hanyoyin jiragen ƙasa na duniya, metros, da ƙayatattun locomotives. Samar da ƙira na yau da kullun, ƙirar ƙima, da saka idanu mai wayo, sun yi fice a cikin matsananciyar yanayi tare da ƙarancin asara, hayaniya, da tsawan rayuwa. Tallace-tallacen da aka keɓance da mafita da sarrafa rayuwar rayuwa, muna tabbatar da tallafi mara kyau daga ƙira zuwa isar da duniya. Tuntuɓe mu don ƙayyadaddun bayanai na fasaha ko nazarin shari'ar - da ke ba da ƙarfin motsinku gaba da gaba gaɗi.

Hot Tags: jirgin kasa transformer, manufacturer, maroki, farashin, tsada
You Might Also Like
6 MVA Railway Transformers-22 / 1.22 kV|Afirka ta Ku...
3000 kVA Mai Canjawa-25 / 0.6 kV|Kanada 2025
2500 kVA Kushin Dutsen Mai Canjawa-12.47 / 0.48 kV|A...
5 MVA Railway Traction Transformer-132 / 1.22 kV|Afi...
630 kVA Vpi Nau'in Canji-11 / 0.55 kV|Afirka ta Kudu...
2000 kVA Kushin Haɗa Mai Canjawa-24 / 0.48 kV|Amurka...
Aika Aikace-aikacen