120 MVA Mai Canjin Wutar Lantarki-132/22 kV|Malaysia 2023

120 MVA Mai Canjin Wutar Lantarki-132/22 kV|Malaysia 2023

Ƙasa: Malaysia 2023
Yawan aiki: 120MVA
Wutar lantarki: 132/33/22kV
Feature: tare da OLTC
Aika Aikace-aikacen

 

 

120MVA power transmission transformer

Inda Babban Ayyuka Ya Haɗu da Dogarorin Dogara.

 

01 Gabaɗaya

1.1 Fagen Aikin

An ƙirƙira shi don ƙaƙƙarfan ƙarfi da inganci, wannan na'urar watsa wutar lantarki mai nauyin 120 MVA, 132/22 kV mai isar da wutar lantarki tana aiki a matsayin kulli mai mahimmanci a cikin grid ɗin lantarki, dogaro mai ƙarfi yana sauka daga matakin watsawa 132 kV zuwa 22 kV sub- watsa ko matakin rarrabawa. An ƙirƙira shi don manyan tashoshin sadarwa masu ƙarfi waɗanda ke ba da wutar lantarki ga manyan masana'antu, manyan cibiyoyin birni, ko manyan hanyoyin sadarwa na yanki. Gina tare da ci-gaba da fasaha na iska, naúrar tana tabbatar da ƙarancin ƙarancin kuzari, gajeriyar juriyar iyawa, da kwanciyar hankali a ƙarƙashin nauyi mai nauyi. Wannan na'urar taswira ta ƙunshi sadaukar da kai ga dorewa da ingantaccen aiki, yana mai da shi kadara ta ginshiƙi don abubuwan amfani da masana'antu waɗanda ke neman haɓaka kwanciyar hankali da ingantaccen isar da wutar lantarki.

 

 

1.2 Ƙayyadaddun Fasaha

120 MVA ikon wutar lantarki ƙayyadaddun bayanai da takaddar bayanai

Isarwa zuwa
Malaysia
Shekara
2023
Samfura
SFSZ-120000/132
Nau'in
Mai Narke Mai Canza Wutar Lantarki
Daidaitawa
Saukewa: IEC60076
Ƙarfin Ƙarfi
120MVA
Yawanci
50HZ
Mataki
Uku
Nau'in Sanyi
OFWF
High Voltage
132KV
Matsakaicin Wutar Lantarki
33KV
Low Voltage
22KV
Abubuwan Iska
Copper
Impedance
35.43%
Matsa Canji
OLTC/NLTC
Taɓa Range
132+7×1.5% -17×1.5%
Babu Asara Load
45KW
Akan Rasa Load
520KW
Na'urorin haɗi
Daidaitaccen Kanfigareshan
Jawabi
N/A

 

1.3 Zane

120 MVA ikon wutar lantarki zane da girman zane.

power transmission transformer diagram power transmission transformer nameplate

 

 

02 Masana'antu

2.1 Kori

120 MVA Transformer core yana da ingantaccen ƙira ta amfani da Laser{1}}rubuta lamintattun lamunin ƙarfe na silicon tare da ingantaccen matakin gini{2}}. Wannan sabuwar dabarar tana rage hasara mai mahimmanci da yin maganadisu a halin yanzu yayin da ke haɓaka kwanciyar hankali a ƙarƙashin bambance-bambancen kaya. Madaidaicin da'irar maganadisu na injiniya{5} yana tabbatar da ingantaccen inganci da ingantaccen aiki don aikace-aikacen watsawa na 132/22 kV, yana ba da dogon lokaci{8} tattalin arzikin aiki da rage tasirin muhalli ta hanyar ƙarancin sharar makamashi.

laminated core power transformer

 

2.2 Guda

power transmission transformer windings

Mai taswirar MVA 120 yana ɗaukar lu'u-lu'u na mallakar mallaka{1}} iskar fayafai da aka ƙera daga iskar oxygen{2}} madugu na jan karfe kyauta. Wannan tsarin haɗin gwiwar yana ba da 25% mafi girma gajeriyar gajeriyar hanya{5}}ƙarfin kewayawa fiye da ƙira na al'ada yayin da yake kiyaye mafi kyawun yanayin zafi. Na musamman axial na windings - sanyaya juzu'i yana tabbatar da rarrabuwar yanayin zafi iri ɗaya a duk matakai, yana faɗaɗa rayuwar rufewa a ƙarƙashin babban aikin hawan keke. Wannan na'ura mai ci gaba yana ba da kwanciyar hankali na musamman don watsawa{9}} aikace-aikacen matakin, haɗe ingantacciyar injin lantarki tare da ƙarancin asara.

 

2.3 Tanko

Tankin na mu 120 MVA transformer yana da siffofi biyu{1} corrugated aluminum panels tare da hadedde tashoshi sanyaya, samar da kai -tsari mai goyan baya wanda ke kawar da wuraren damuwa na thermal. Rufin nanoceramic ɗin sa yana ba da juriya na musamman na lalata yayin da yake riƙe mafi kyawun zubar da zafi. Ƙirar monobloc ta ƙunshi musaya masu sa ido na lokaci na gaske- kuma yana fasalta shimfidar kayan haɗi na zamani don ingantaccen sabis. Wannan sabuwar dabarar tana tabbatar da ingantacciyar kwanciyar hankali na inji da 30% mafi kyawun sanyaya inganci idan aka kwatanta da ƙirar al'ada, tana ba da amincin da bai dace ba don mahimman kayan aikin watsawa.

power transmission transformer tank

 

2.4 Taron Karshe

power transformer

Haɗin ƙarshe na na'urar watsawa ta MVA 120 ɗinmu tana haɗa lu'u-lu'u na mallakar mallaka{1}}wararren iska da Laser{2}mararriyar cibiya a cikin tanki na almuni mai ruɓi biyu{3}, ƙirƙirar tsari mai jituwa tare da ingantaccen aikin zafi 40%. Duk manyan abubuwan da suka dace sun dace - ta hanyar amfani da fasahar tagwayen dijital a yayin taron masana'anta, suna tabbatar da ingantattun halayen lantarki da amincin injina. Naúrar tana jujjuya matakan daidaitawa na mallakar mallaka wanda ke ƙayyadadden tsarin rufewa kafin jigilar kaya. Wannan cikakken tsarin aikin injiniya yana ba da hanyar watsawa{9} shirye-shiryen bayani tare da ingantattun ma'aunin aikin da ya wuce ma'aunin masana'antu don dogaro da sassaucin nauyi.

 

 

03 Gwaji

Canjin mu na MVA 120 yana fuskantar gwajin bincike na ci gaba wanda ya haɗa da Binciken Amsa Amsa (FRA) da ma'aunin fitarwa na yanki ƙarƙashin damuwa na aiki. Waɗannan hanyoyin tabbatarwa na mallakar mallaka suna tabbatar da amincin tsari da aikin rufewa fiye da daidaitattun buƙatu, yana tabbatar da ingantaccen aminci don aikace-aikacen watsawa mai mahimmanci.

 

image007

 

 

04 Shiryawa da jigilar kaya

image008 image009

05 Yanar Gizo da Takaitawa

Binciken Gidauniya:Tabbatar da tushe matakin da ƙasa.

Matsayi:Sanya naúrar daidai ta amfani da tsarin jacking.

Majalisar:Sanya bushings, radiators, da mai adanawa.

Cika Mai:Vacuum degas mai, sa'an nan cika transformer.

Haɗin Ƙarshe:Haɗa duk igiyoyin sarrafawa da wutar lantarki.

Gwaji:Yi gwajin insulation da rabo.

Ƙarfafawa:Kunna kuma saka idanu aikin farko.

Mayar da hankali: Tsaftace komai da danshi{0}free.

120 MVA high voltage power transformers

 