100 kVA Mai Canja Wuta Mai Wuta-13.8 / 0.24 kV|Guyana 2025

100 kVA Mai Canja Wuta Mai Wuta-13.8 / 0.24 kV|Guyana 2025

Ƙasar Bayarwa: Guyana 2025
Yawan aiki: 25kVA
Wutar lantarki: 13.8kV-240/120V
Aika Aikace-aikacen

 

 

100 kVA transformer pole mounted

100 kVA guda ɗaya -lokacin sandar sandar sandar wuta mai ɗaure tafsiri{2}}wanda aka gina don tsayayyiyar ƙarfi a cikin ƙaramin ƙarfi{3}}yawa, dogayen rarraba nesa{4}}
 

01 Gabaɗaya

1.1 Fagen Aikin

Wannan 100 kVA guda 100 na wutar lantarki da aka ɗora, wanda aka kawo wa Guyana a cikin 2025, an ƙirƙira shi bisa ƙa'idodin IEEE da ANSI C57.12.00. Tare da babban ƙarfin lantarki na 13,800 V da ƙarfin lantarki na biyu na 120/240 V, yana da kyau don rarraba kasuwancin zama ko haske a yankunan karkara ko kewayen birni inda ake buƙatar sabis na lokaci ɗaya-. Sanyayawar ONAN, iskar jan ƙarfe, da ƙarancin ƙarfi suna tabbatar da babban aminci da dorewa a cikin muhallin waje. ± 2×2.5% mai canza famfo NLTC yana ba da izinin ƙayyadaddun ƙayyadaddun wutar lantarki, yana mai da shi dacewa da wuraren da ke da jujjuyawar wutar lantarki ko watsa mai nisa. Ƙirar da aka ɗora madaidaicin sandar wutan lantarki yana da tasiri musamman don farashi{16}} ingantaccen turawa a yankuna masu ƙarancin yawan jama'a.

1.2 Ƙayyadaddun Fasaha

100kVA guda lokaci iyakacin duniya saka gidan wuta ƙayyadaddun bayanai da takardar bayanai

Isarwa zuwa
Guyana
Shekara
2025
Nau'in
Juzu'i guda sandar sandar da aka saka taransifoma
Daidaitawa
IEEE & ANSI C57.12.00
Ƙarfin Ƙarfi
100 kVA
Yawanci
60HZ
Polarity
Ragewa
Ƙungiyar Vector
Ii0
Babban Voltage
13800 V
Na biyu Voltage
120/240 V
Abubuwan Iska
KWANA
Impedance
2%
Hanyar sanyaya
ONAN
Matsa Canji
Farashin NLTC
Taɓa Range
± 2X2.5% (Jimlar kewayon =10%)
Babu Asara Load
263 W
Akan Rasa Load
1160 W
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

100kVA guda lokaci iyakacin duniya saka taswira girma da nauyi cikakken bayani

100kVA single phase pole mounted transformer drawing

 

 

02 Masana'antu

2.1 Kori

A cikin masana'antar taswira, ainihin yana taka muhimmiyar rawa a matsayin babbar hanya don jigilar maganadisu, yana shafar aiki kai tsaye da inganci. A cikin hoton, ana shirya muryoyin birgima da yawa da kyau bayan an wuce kima da matsayi. Ma'aikata suna bin ingantattun hanyoyin don tabbatar da tsattsauran ra'ayi mai daidaitawa, shirya ma'auni don madaidaicin hadawar coil da mataki na gaba na ginin sashin aiki.

100kVA single phase pole mounted transformer iron core

 

2.2 Guda

100kVA single phase pole mounted transformer winding

100kVA madaidaicin sandar sandar da aka ɗora wutar lantarki yana amfani da windings na jan karfe. Ƙarƙashin wutar lantarki yana ɗaukar iska mai ƙarfi tare da babban tagulla mai ƙarfi{2}, rauni tare da rufin rufi. Babban ƙarfin wutar lantarki yana amfani da wayar jan ƙarfe mai enameded, daidai rauni tare da rufi tsakanin yadudduka. Bayan dasawa, ana bushewar coils kuma ana warkewa don haɓaka ƙarfin rufi da amincin dogon lokaci-.

 

2.3 Tanko

Tankin mai na ƙarfe mai laushi, tare da radiyo na ɓangarorin biyu, ana yin gwajin inganci da kyau kafin haɗuwa. A cikin hoton, ma'aikata suna yin gwaje-gwaje masu girma ta hanyar auna mahimman sassa, gudanar da bincike na gani don gano lahani ko al'amurran walda, da kuma tabbatar da yanayin jiyya. Waɗannan cikakkun bayanai sun tabbatar da tankin mai ya cika ka'idojin da ake buƙata don ingantaccen aikin taswira.

mild steel oil tank of 100 kVA transformer pole mounted

 

 

03 Gwaji

Gwajin yau da kullun

1. Ma'aunin Juriya

2. Gwajin Rabo

3. Gwajin Polarity

4. Babu Asara Load Kuma Babu Load A Yanzu

5. Load Loss da Impedance Voltage

6. Gwajin Karfin Wutar Lantarki

7. Gwajin Juriya da Ƙarfin Wutar Lantarki

8. Ma'aunin Juriya na Insulation

9. Gwajin Dielectric Oil

10. Gwajin Leak tare da Matsi don Masu Canjin Ruwa na Immersed

 

Matsayin Gwaji

• IEEE C57.12.20-2017

Matsayin IEEE don Sama - Nau'in Rarraba Transformers 500 kVA da Karami; Babban ƙarfin wutar lantarki, 34500 V da ƙasa; Low Voltage, 7970/13 800YV da kasa

• IEEE C57.12.90-2021

IEEE Standard Code Test for Liquid -Rarraba Rarraba, Ƙarfi, da Gudanar da Masu Canjawa

CSA C802.1-13 (R2022)

Ƙimar Ƙarfin Ƙarfi don Liquid{0}}Cikakken Masu Canza Rarraba

 

Sakamakon Gwaji

A'a.

Gwajin Abun

Naúrar

Dabi'un Karɓa

Ƙimar Ma'auni

Kammalawa

1

Ma'aunin Juriya

/

/

/

Wuce

2

Gwajin Rabo

/

Bambancin rabon ƙarfin lantarki akan babban tapping: ƙasa da ko daidai da 0.5%

Alamar haɗi: Ii0

-0.03

Wuce

3

Gwajin polarity

/

Ragewa

Ragewa

Wuce

4

A'a -asara da tashin hankali na halin yanzu

%

kW

I0 :: bayar da ma'auni darajar

P0: ba da ƙima mai ƙima

juriyar rashin hasara shine +10%

0.49

0.225

Wuce

5

Load asarar, impedance ƙarfin lantarki, jimlar asarar da kuma yadda ya dace

/

kW

kW

t:85 ku

Z%: ƙimar da aka auna

Pk: ƙimar ƙima

Pt: ƙima mai ƙima

haƙuri ga impedance shine ± 10%

juriyar jimlar asarar kaya shine +6%

2.33

0.857

1.082

99.17

Wuce

6

Gwajin Karfin Wutar Lantarki

/

HV: 34KV 60s

LV: 10kV 60s

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

7

Jarrabawar Juriya da Wutar Lantarki

/

Wutar lantarki mai aiki (KV):

2 Ur

Duration(s): 48

Mitar (HZ): 150

Babu rushewar ƙarfin gwajin da ke faruwa

Wuce

8

Ma'aunin Resistance Insulation

GΩ

HV{0}LV zuwa Ground

LV -HV zuwa Ground

HV&LV zuwa Ground

35.9

17.4

16.2

Wuce

9

Gwajin Leaka

/

Aiwatar da matsa lamba: 20kPA

Tsawon lokaci: 12h

Babu yabo kuma babu

Lalacewa

Wuce

10

Gwajin Dielectric Oil

kV

Yafi ko daidai da 45

56.41

Wuce

 

100 kVA transformer pole mounted testing
100 kVA transformer pole mounted test

 

 

04 Shiryawa da jigilar kaya

100 kVA transformer pole mounted packaging
100 kVA transformer pole mounted shipping

 

05 Yanar Gizo da Takaitawa

Wannan 100kVA guda ɗaya -ƙara mai ɗaure{2}} na'ura mai ɗaukar wuta yana da kyau don rarrabawa waje a ƙauye ko kewaye inda babban ƙarfin lantarki na 13.8kV ya sauko zuwa ƙarfin lantarki na sakandare 120/240V. Yana nuna iskar tagulla, sanyin yanayi na ONAN, da ±2 × 2.5% babu-mai sauya famfo, yana ba da babban abin dogaro da ka'idojin wutar lantarki{10}}cikakke ga yankuna masu jujjuyawar wutar lantarki ko isar da wuta mai nisa. Ƙirƙirar ƙirar sa da sauƙi na hawan sandar sanda yana sa shi farashi{13}} tasiri ga ƙananan yawan jama'a{14}}.

Idan aikinku yana buƙatar:

• Ƙarƙashin ƙarfi zuwa matsakaici ɗaya{0}}ƙarfin lokaci

• Ƙunƙwasa na waje{0}} shigarwa

• Tsayayyen ƙarfin lantarki a ƙarƙashin layukan rarrabawa ko tsawaitawa

• Ingantacciyar iskar jan ƙarfe da sanyaya yanayi don rage farashin kulawa

Wannan transformer yana da kyau kwarai dacewa. Tuntube mu don ƙarin cikakkun bayanai da zaɓuɓɓukan gyare-gyare.

100 kVA transformer pole mounted

 

 

 

Hot Tags: wutan lantarki da aka saka, masana'anta, mai kaya, farashi, farashi

Aika Aikace-aikacen