300 KVA Mai Cika Masu Canjin Mai-4.16 / 0.6 KV|Kanada 2025

300 KVA Mai Cika Masu Canjin Mai-4.16 / 0.6 KV|Kanada 2025

Kasar: Kanada 2025
Yawan aiki: 300kVA
Wutar lantarki: 4.16/0.6 kV
Feature: tare da Luminol mai
Aika Aikace-aikacen

Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'anta kuma masu samar da tasfomai masu cike da man kva 300{6}}4.16/0.6 kv|kanada 2025 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

 

oil filled transformers

Dogara a cikin ƙasa: Kushin Haɗa Masu Canja-canje don Makamashi mara Katsewa.

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

2000 kVA three phase pad mounted transformer an isar da ita zuwa Kanada a shekarar 2025. Ƙarfin wutar lantarkin shine 300 kVA tare da sanyaya KNAN. Babban ƙarfin lantarki shine 4.16Y / 2.4 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.6D kV, sun kafa ƙungiyar vector na YNd1.

SCOTECH's pad mounted transformer shine ƙaƙƙarfan, cikakken ruɓaɓɓen bayani na rarrabawa wanda aka ƙera don aikace-aikacen waje da na waje-. An ƙera shi da lallaɓawa{2}}karfe mai juriya da ƙwanƙolin hatimin hatimi{3}}da{4}}, wannan na'urar lantarki tana kawar da haɗarin ƙura, danshi, da gurɓatawar waje, yana tabbatar da tsayayyen aiki ko da a cikin matsananciyar yanayi kamar wuraren shakatawa na masana'antu, rukunin kasuwanci, da unguwannin zama. Ƙarƙashin ƙarancin ƙarancin nauyi-asara da ƙananan matakan amo, yana bin ƙa'idodin ƙasa da ƙasa ciki har da IEEE, CSA da sauran ƙa'idodi na duniya, daidaita ƙarfin kuzari tare da ingantaccen rarraba wutar lantarki. Ƙirar sa ta ƙasa{8} tana kawar da buƙatun manyan tsaunuka, sauƙaƙe shigarwa, rage farashin shirye-shiryen wurin, da haɓaka amincin aiki don ma'aikatan kulawa da jama'a iri ɗaya. Mafi dacewa don haɓaka grid na wutar lantarki na birane da tsarin samar da makamashi, SCOTECH's pad mounted transformer yana ba da daidaiton aiki don biyan buƙatun samar da wutar lantarki daban-daban.

 

 

 

1.2 Ƙayyadaddun Fasaha

300 kVA kushin da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai

Isarwa zuwa
Kanada
Shekara
2025
Nau'in
Tashin wutar lantarki
Daidaitawa
CSA C227.4:21
Ƙarfin Ƙarfi
300 kVA
Yawanci
60HZ
Mataki
3
Ciyarwa
Madauki
Gaba
Matattu
Nau'in Sanyi
ONAN (Luminol oil)
Babban Voltage
4.16Y/2.4kV
Na biyu Voltage
0.6d kV
Abubuwan Iska
Copper
Ƙungiyar Vector
YNd1
Impedance
4%
inganci
98.94%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
0.65 kW
Akan Rasa Load
4.25 kW

 

1.3 Zane

300 kVA kushin da aka ɗora zane da girman hoto.

oil filled transformers diagram oil filled transformers nameplate

 

 

02 Masana'antu

2.1 Kori

oil filled transformers core

The uku {{0}phase three{1}} ginshiƙi na kushin mounted transformer daidai yake{2}}injiniya ta amfani da high{3}}grade sanyi{4}mirgina hatsi{5}}Silicon karfe, featuring m, m, simmetric three-gagarumin tsarin da daidai dace da taswirar sarari{7}. Wannan ainihin ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun maganadisu da ultra{10}}ƙananan asara{11}}, yana rage ɓarnawar kuzari yadda yakamata yayin canjin wuta. Ƙarfin gininsa yana haɓaka kwanciyar hankali na da'irar maganadisu, yana goyan bayan samar da wutar lantarki na lokaci uku{13}, kuma yana jure rawar jiki da damuwa na mahalli na kayan aiki na sama, yana mai da shi maɓalli mai mahimmanci na tsawon lokacin na'ura mai canzawa, babban aiki mai inganci.

 

2.2 Tanko

An gina tankin da aka ɗora tafsirin tafsirin daga babban ƙarfe{0}}ƙarfi-karfe mai ƙarfi, yana ɗauke da cikakken tsarin walda, tsarin hatimin hatimi wanda aka inganta don shigar da ƙasa ko rabin ƙasa. Yana da gidaje masu sanyaya mai don sanyaya da rufe kayan cikin gida, yayin da ƙaƙƙarfansa, lalata{4}}ƙarshensa da daidaito{5}waɗanda aka welded suna kare kariya daga danshi, ƙura, da lalacewar jiki a cikin masu tafiya a ƙasa{6}}wasu waje. Madaidaicin buɗaɗɗen buɗaɗɗen buɗaɗɗen buɗaɗɗen da ƙarfafa wuraren hawa suna tabbatar da haɗin kai mara kyau tare da abubuwan taimako, yana ba da dorewar lokaci mai tsawo da ingantaccen aiki don cibiyoyin rarraba wutar lantarki na birni da na birni.

oil filled transformers tank

 

2.3 Luminol mai

Luminol Oil

Man Luminol da ake amfani da ita a cikin taswirar da aka ɗora taswira shine babban abin rufe fuska da sanyaya matsakaicin injiniya wanda aka ƙera shi don yanayin aiki na ƙarƙashin ƙasa, Semi{0} na waɗannan raka'a. Yana ba da injunan lantarki mai ƙarfi don hana yin kisa na ciki tsakanin abubuwan haɗin gwiwa, yayin da ya dace da watsar da zafi da aka samar yayin aiki don kula da ingantaccen aiki. Tare da babban madaidaicin walƙiya, ƙaramin madaidaicin juriya, da kyakkyawan juriya na iskar oxygen, yana tsayayya da lalatawar thermal kuma yana tsawaita rayuwar sabis na taswira, yayin da tsarin sa na eco{3} ya dace da ƙa'idodin muhalli na zamani, yana tabbatar da abin dogaro, ƙarancin{4}aiki na kulawa don tsarin rarraba wutar lantarki na birni da na kewayen birni.

 

2.4 Wurin Cika Mai

Bawul ɗin cike mai don masu na'urar wuta, an ƙera shi daga lalata{0}taguwar tagulla kamar yadda aka nuna, wani abu ne da ake sarrafa shi da hannu wanda aka tsara don sarrafa amintaccen allura da toshe mai a cikin tankin da aka hatimi na taransfoma. Ƙarfinsa, ƙwanƙwasa{3}}tsattsarin gininsa yana haifar da hatimin hatimin hatimi idan an rufe shi, yana hana danshi da gurɓataccen abu daga lalata tsaftar mai da aikin dielectric, yayin da ergonomic wheel wheel yana kunna daidai, madaidaiciyar aiki yayin shigarwa da kulawa na yau da kullun.

Oil Filling Valve

 

2.5 Babban ƙarfin wutar lantarki

High voltage Bushing

Babban filogi{0}voltage{1} da ke cikin bushing for pad mounted transformers shine ƙwaƙƙwaran, kayan aikin epoxy{2} da aka kera don aminci, saurin shigarwa da cirewa a cikin ruɓaɓɓen raka'a na ƙasa. Yana ba da ingantacciyar insilar lantarki don keɓance manyan masu sarrafa wutar lantarki{4} daga tankin ƙarfe na taswira, yana hana zubewa da zubewa yayin da yake tsayayya da danshi, ƙura, da lalata. Fuloginsa - a cikin ƙira yana kawar da hadaddun wayoyi, yana ba da damar ingantaccen kulawa da rage lokacin raguwa, yana mai da shi zaɓi mai amfani don cibiyoyin rarraba wutar lantarki na birni da na kewayen birni.

 

 

03 Gwaji

CSA - Gwajin Jurewar Wutar Lantarki na Ƙarfafawa don ɗorawa masu ɗorawa na pad muhimmin ƙima ne mai mahimmanci, wanda aka gudanar ta kowane ma'auni na CSA don tabbatar da ƙarfin wutar lantarki na iska. Ana amfani da wutar lantarki kusa -sinusoidal (a mitar sama da aka ƙididdigewa don gujewa wuce gona da iri) zuwa iskar, ana kimanta juyowa -zuwa-juyawa, lokaci{5}}zuwa-phase, da winding-zuwa-shafin ƙasa. Ana kiyaye gwajin na tsawon ƙayyadaddun lokaci, tare da nasarar kammalawa ba tare da rushewar wutar lantarki ba, walƙiya, ko fitar da ɓarna mai cutarwa{10}} yana tabbatar da amintaccen aikin na'urar wuta, amintaccen aiki a rufaffiyar, mahallin ƙasa.

CSA-compliant Induced Voltage Withstand Test
CSA standards

 

 

04 Shiryawa da jigilar kaya

4.1 Shiryawa

Marufi na kushin da aka ɗora wutar lantarki ya haɗa da sanya jakar foil ɗin tin akan tire mai canzawa, ƙara desiccant a ciki, rufe gidan wuta tare da jakar foil ɗin kwano (an rufe shi da buɗewa don vacuuming kafin rufewa ta ƙarshe ta hanyar sealer), shigar da kumfa / filastik / kwali kusurwa masu kariya a kusa da naúrar, nannade shi tare da fim ɗin katako, sannan a rufe shi da fim ɗin kariya. alamun nauyi{0}} yana tabbatar da rigakafin tsatsa da sufuri mai lafiya.

 

4.2 Shipping

Ana isar da tasfoma na kushin SCOTECH ta hanyar jigilar ruwa a ƙarƙashin sharuddan CIF Edmonton, Kanada; an kiyaye raka'a cikin marufi masu dacewa da ruwa, girgiza{0}mai jurewa, an ɗora su cikin daidaitattun kwantena a tashar jirgin ruwa, kuma an rufe su da cikakkiyar inshorar jigilar ruwa akan asara ko lalacewa har sai an isa tashar jiragen ruwa ta Edmonton lafiya, tare da cikakken bin ka'idojin CSA da dokokin shigo da Kanada a duk lokacin wucewar.

 

 

05 Yanar Gizo da Takaitawa

Zaɓi kushin SCOTECH {0} da aka ɗora tafsiri don dogaro mara misaltuwa, cikawa mara kyau tare da ƙa'idodin IEEE/CSA, da kuma ingantaccen aiki wanda ya dace da ƙaƙƙarfan buƙatun hanyoyin rarraba wutar lantarki na Kanada. An goyi bayan ƙwararrun shekarun mu na masana'antar taswira da cikakken tallafin tallace-tallace -, samfuranmu suna isar da daidaitattun hanyoyin samar da wutar lantarki don ci gaba da gudanar da ayyukanku cikin sauƙi. Tuntube mu a yau don tattauna takamaiman buƙatun ku kuma bari SCOTECH ta zama amintaccen abokin tarayya don samar da ingantaccen makoma.

IEEE/CSA standards

 

Hot Tags: mai cike da wutar lantarki, masana'anta, mai kaya, farashi, farashi