Horon Samfurin Ƙarƙashin Ƙarƙashin Ƙarƙashin Ƙarfafa Ƙarfafa Ƙwararrun Taimakon Fasaha
May 07, 2026
Bar sako

Don ingantacciyar tallafawa rarraba wutar lantarki ta duniya da ayyukan makamashi mai sabuntawa, kwanan nan SCOTECH ta shirya taron horar da samfur na cikin gida wanda ke kewayeKaramin Substationsdon tallace-tallace na kasa da kasa da ƙungiyoyin tallafi na aikin.
Kamar yadda ayyukan ƙasashen waje ke zama ƙayyadaddun ƙayyadaddun ayyuka{0}, abokan ciniki suna mai da hankali ba kawai ga yarda da IEC ba, har ma da daidaita kayan aiki, amincin sufuri, ingancin shigarwa, da amincin dogon lokaci. Makasudin zaman shine don ƙarfafa fahimtar ƙungiyar game da daidaitawar samfur, buƙatun aikin, da ayyukan fitar da kayayyaki masu amfani.
An ƙara shirya mahimman kayan daga wannan zaman zuwa jagorar fasaha don tunani, rufe ƙirar tsarin, ƙa'idodin zaɓi, ƙa'idodin IEC, da ayyukan injiniya:Zaɓin Ƙaƙwalwar Tashoshi da Jagoran Injiniya
Karamin Substation Fundamentals daAikace-aikace

An fara zaman ne tare da tushen ƙaƙƙarfan ƙananan tashoshin yanar gizo - tsarin su, ƙa'idodin aiki, da tsarin gaba ɗaya. Mahalarta sun yi bitar ayyuka na babban rukunin wutar lantarki{2}, rukunin wutan lantarki, da ƙananan rukunin wutar lantarki, tare da ainihin ma'anar da ke bayan canjin wutar lantarki da rarrabawa.
An kuma tattauna yanayin aikace-aikacen gama gari da yawa, gami da tsarin rarraba kayan aiki, ayyukan hasken rana, da ayyukan makamashin iska. Hanyoyi daban-daban na ƙirar ƙira don waɗannan ayyukan an kwatanta su don taimakawa ƙungiyar su fahimci yadda buƙatun abokin ciniki na iya bambanta daga wannan masana'anta zuwa waccan.
A hakikanin aikin harka, da1600 kVA Compact Substation Transformer (33/0.4 kV, Habasha, 2022), an kuma gabatar da shi azaman tunani mai amfani don kwatanta yadda ake aiwatar da ƙananan hanyoyin samar da wutar lantarki a cikin ayyukan rarraba wutar lantarki na ketare.
Horon ya kuma shafi batutuwan zaɓe masu amfani da ake yawan fuskanta a ayyukan fitarwa, gami da:
- Karamin zaɓin gidan wuta
- Wuraren da'ira da lodawa{0}masu kashewa
- Ƙarƙashin daidaitawar canjin wutan lantarki-
- Tsarin shinge da ƙimar kariya
- Asalin zane-zanen layi daya{0} da kuma zane-zane
Bugu da kari, zaman ya gabatar da hanyoyin zayyana, tsare-tsare na sufuri, matakan kariya na loda kwantena, bukatu na shirye-shiryen tushe, jagorar shigarwa, da kuma wuraren da aka fara gudanar da bincike - wuraren da abokan ciniki na duniya sukan tambaya akai yayin tattaunawar aikin.
Ka'idodin Ƙasashen Duniya da Bukatun Biyayya
Saboda bin ƙa'idodi ɗaya ne daga cikin mahimman abubuwan da ke damuwa a cikin ayyukan ƙasashen waje, an ba da kulawa ta musamman ga buƙatun IEC da aka saba amfani da su ga ƙayyadaddun ƙayyadaddun ƙayyadaddun kayan aiki da makamantansu.
Horon ya ƙunshi mahimman ƙa'idodi na duniya da yawa, waɗanda suka haɗa da:
- IEC 62271-202 -Maɗaukaki -arfin wutar lantarki da kayan sarrafawa - Kashi na 202: Babban{3}}ƙarfin wutar lantarki/ƙananan{4}}waɗanda aka riga aka ƙirƙira wutar lantarki
Wannan ma'auni yana ƙayyadaddun buƙatun fasaha, hanyoyin gwaji, da buƙatun aminci don ƙarami.
- IEC 60076 Series {1} Masu Canza Wuta
Rufe buƙatun aikin na'ura mai canzawa, matakan rufewa, iyakokin haɓakar zafin jiki, da buƙatun gwaji don ƙaƙƙarfan taswira.
- IEC 60439 Series - Low{2}}arfin wutar lantarki da taruka masu sarrafawa
Masu alaƙa da aiki da buƙatun fasaha na ƙananan taro na ƙarfin lantarki da abubuwan haɗin LV na ƙananan -.
- Jerin IEC 61439 - Low{2}}arfin wutar lantarki da taruka masu sarrafawa - Kashi na 1: Gabaɗaya dokoki
Samar da ƙarin tabbacin ƙira da buƙatun aminci don ƙananan tsarin sauya wutan lantarki-.
Horon ya kuma jaddada mahimmancin fahimtar ƙasa{0} takamaiman buƙatun takaddun shaida da ƙayyadaddun abokan ciniki, musamman don ayyukan fitar da kayayyaki da suka haɗa da kayan aiki, wuraren masana'antu, da sabbin kayan aikin makamashi.
Zaɓin Fasaha da Haɗin gwiwar Ayyukan Fitarwa
Ta fuskar kasuwancin fitarwa, horon ya tattauna batutuwa masu amfani da yawa waɗanda ke shafar aiwatar da aikin kai tsaye:
- Binciken farashi da shirye-shiryen zance
- Shirye-shiryen sufuri da tsarin kwantena
- Hanyoyin tsaro na kayan aiki yayin jigilar kaya
- Bukatun tushe na rukunin yanar gizon
- Kariyar shigarwa da ƙaddamarwa
Ana yin watsi da waɗannan cikakkun bayanai da wuri a cikin aikin, amma suna iya tasiri sosai akan jadawalin isarwa, ingancin shigarwa, da ƙwarewar abokin ciniki gaba ɗaya.
Ƙarfafa Haɗin kai Tsakanin Ƙungiyoyi


Horon ya haɗu da mambobi daga sashen tallace-tallace na kasa da kasa, ƙungiyar injiniya, sashen samarwa, da kuma sashin kula da inganci, yana taimakawa wajen ƙarfafa haɗin kai na ciki a duk lokacin aikin.
An kuma sake duba misalan ayyuka masu amfani da kuma ainihin ƙaƙƙarfan ƙira na ƙira a yayin zaman. Ta hanyar haɗa tattaunawa ta fasaha tare da ainihin yanayin aikin fitarwa, mahalarta sun sami ƙarin fahimtar tsammanin abokin ciniki da bukatun aikace-aikace a kasuwanni daban-daban.
Taimakawa Ayyukan Wutar Lantarki na Duniya tare da Ci gaba da Koyo
A matsayin ƙwararrun masana'anta na samar da kayan aiki na duniya, masana'antu, da kasuwannin makamashi masu sabuntawa, SCOTECH na ci gaba da saka hannun jari a horon fasaha da haɓaka ilimin samfuri a cikin ƙungiyoyi.
Ta hanyar ci gaba da ilmantarwa da kusanci tsakanin sassan, kamfanin yana da niyyar samar da martanin fasaha cikin sauri, ingantaccen tallafin aikin, da ƙarin amintattun hanyoyin samar da ƙaramin yanki ga abokan ciniki a duk duniya.