Gano Magnetic da Lantarki don Tankunan mai Tankuna
Jul 02, 2025
Bar sako
A yayin aiwatar da mai canzawa, babban juji ya wuce ta bakin ciki zai haifar da farin ƙarfe asarar, da na yanzu a cikin iska zai sa asarar jan karfe. Baya ga waɗannan nau'ikan asarar guda biyu, ƙarfin leakeran ruwa da ke gudana daga yanayin lokacin da Core yana haifar da ƙarin asara a kan tsarin canji. Wadannan kasuwar quqi sun hada da isassun wuta, core clamps, Core crams, Core zanen gado, da tankuna mai.
Daga gare su, a cikin babba- opacity tracity m, bangon mai mai ya zama daya daga cikin manyan wurare na ƙarin yankin saboda tsinkayen filin magnetic filin. Wannan bangare na asarar ba kawai yana haɓaka asarar kuzari ba amma yana iya haifar da overheating na bango mai, yana shafar aminci da amincin aiki.
![]() |
Domin magance ƙarin asarar bango mai na mai, hana silicon karfe (amfani da faranti na siliki) galibi ana amfani da zane na silicon ko faranti na aluminum) a cikin tankar mai. Wadannan kayan kare kariya na iya jagora ko sha zubar da ruwa, ta yadda zai rage tasirin sa a tanki mai da sauran sassan tsarin, kuma akwai mahimman matakan don inganta ingantaccen aiki da rayuwar mai canzawa. |
| Hoto na 1: Canjin Fasali Magnetic Filin |
Tsarin kare tsarin Magnetic
Hoto na 2: Gyaran mai Magnetic Garkuwa
a) tsiri - ir} engen tsawo gubnic (Magnetic garkuwa da Magnetic Height
b) takardar - engen tsawo garkuwa (Magnetic garkuwa
Akwai tsarin garkuwar magnetic don tankokin mai, kamar yadda aka nuna a cikin Hoto na 2. Daya ya haskaka silicon tare da fadin rauni, kamar yadda aka nuna a hoto 2a. Lokacin da aka yi amfani da irin wannan garken Magnetic, ƙwayar leakta ta shiga garkuwar magnetic daga cikin ikon ƙarfe na silicon, da kuma asarar siliny na Magnetic karami ne; Sauran nau'in garkuwar Magnetic shine takardar {5 0 0 0 0 0 01} mai siffofin Magnetic, wanda aka sanya a cikin bango na 2B, sannan kuma an sanya shi a bango mai mai. Wannan nau'in garkenin Magnetic yana da babban rashi na yanzu a cikin garkuwa ta Magnetic saboda leakyarwa ta shiga cikin magnetic ta shiga cikin magnetic. Koyaya, na ƙarshen garwa na Magnetic yana da sauki don samarwa fiye da na farkon.
Masana'antu yawanci suna amfani da garkuwar Magnetic bisa ga ƙayyadaddun ƙayyadadden magana, sarrafa raunin garken magnetic don zama ƙarami ne, kuma ana riƙe hauhawar jini a cikin kewayon da ba shi izini.
Hoto na 3: Yawan Lafiya na Rushin Rushin Gwajin Magnetic ya shigo Wallan Tank
a) Firist na magnetic filayen
b) Leakage ruwan lemo ya shiga bangon tanki ba tare da kare Magnetic ba
c) leakage likafa a cikin garkuwa da Magnetic
Lissafin ƙididdigar magnetic na magnetic a cikin garkuwar Magnetic ya dogara ne da rarraba ɓoyayyen lugan ruwa a cikin mai canzawa. Hoto na 1 yana nuna haƙurin sihiri a cikin mai canzawa, da kuma rarraba abubuwan fashewa da ke shiga bango mai mai 3.
A cikin Hoto na 3, BM shine amplitude daga cikin tsinkayen da ya haifar da garken mai da garwa na magnetic a tsakiyar tanki mai kuma garkar magnetic. Magnetic Frix a cikin garkuwa da Magnetic shine yadda ya danganta da magnetic ya yi yawa tare da tsawo, wanda ya haifar da adadi da aka nuna a hoto na 3C. Rarraba yankin na Magnetic ta hanyar magnetic ya ba da gudummawar magnetic na magnetic a cikin garkuwa.
Yin amfani da garkuwar magnetic na iya ƙara kayan radial na tsinkaye na ɓoyayyen ɓoyayyen juji na yau da kullun na radial na iska da kuma yawan zafin jiki na gida na radial. A lokacin da eddy asarar lokacin iska da la'akari da zafin yanayin zafin zafi da zafi akan rarraba filin da ya haifar.
Amfani da garkuwar Magnetic na iya rage asarar tanki mai. Bayan amfani da garkuwa ta Magnetic, asarar mai tanki shine jimlar asarar a cikin bango mai mai da hasara a cikin garkuwa mai Magnetic.
Lokacin amfani da garkuwar magnetic, kula da gyarawa game da kare Magnetic da tabbatar da kyawawan garkuwa da Magnetic. Idan ba a daidaita gusar da Magnetic da kyau ba, hayaniyar na iya ƙaruwa saboda rawar jiki, da kuma ƙasa mai kyau na iya haifar da fitarwa na gida saboda matsakaicin tafiye-tafiye.
Ka'idojin Magnetic Garkuwa
Magnetic garkuwa yana gina hanyar juriya na magnetic nesa fiye da farantin karfe ta hanyar kwanciya na tanki na ciki, yana tilasta tsinkaye magnetic mai tsauri da kuma mai da hankali ta hanyar kare. Wannan tsari ne ainihin zabin yanayi na sihiri {{1} 3. Zamanin dokar "silicon, ta rage hadarin mai zafi overheating. A lokaci guda, a matsayin mai karfi na iya hana magnetic shunt, magnetic garkuwa da ya bazu a waje da mai karɓuwar filin tanki (musamman da wani yanki mai rauni), da kuma kawar da wani yanki mai rauni a cikin kayan aikin. Kudin shi ne na kare kariya yana samar da asarar hysteris da Eddy na yau da kullun don ɗaukar nauyin siliki mai ƙarfi (wanda za'a iya inganta silnicle (garkuwa) karfinsu.
Lantarki
Hakanan ana amfani da garkuwar lantarki don kare garkuwar mai mai mai na mai a {{0} Tirrika mai ƙarfi, musamman masu shinge na zafi kusa da babban jigon yanzu.
Kirkirar lantarki yana amfani da rijiyoyin Eddy a cikin faranti don sake rarraba luldo. Ayyukan sa shine haɓaka juriya na Magnetic Garkuwa ta ɓangaren lantarki, saboda barin ɓoyayyen asarar da ke cikin gida da kuma kawar da asarar gida da kuma kawar da yanayin gida.
Tunda akwai allurai Eddy a cikin garkuwa da wutar lantarki, akwai asarar a cikin garkuwa da kanta, don haka asarar tanki mai shine asarar hasara a cikin bangon mai a cikin garkuwa mai.
Gabaɗaya, lokacin amfani da faranti a matsayin garkuwar lantarki a matsayin garkuwar lantarki, kauri daga cikin fararen fararen aluminu kusan 8mm ne kusan 8mm; A lokacin da amfani da faranti a matsayin garkuwar lantarki, kauri daga faranti faranti kusan 4mm ne.
Tunda garkuwar lantarki tana da Eddy na yanzu shine, garkuwar lantarki zai rage asarar mai narkewa na yanzu, amma kuma yana rage asarar mai na ruwa na yanzu na iska. Tasirin amfani da giyarwar Magnetic da Lantarki don rage ƙarin asarar da aka nuna a cikin tebur, da kuma sauran asara lokacin amfani da garkuwar Magnetic shine 100% don kwatantawa.
| Hasara | Jimlar ƙarin asara (%) | Asara a cikin tankar mai (%) | Asara a cikin iska (%) |
| Magnetic garkuwa | 100 | 8 | 86 |
| Lantarki | 172 | 8 | 24 |
| Babu garkuwa | 372 | 318 | 54 |
Dangantaka tsakanin ƙarin asara da hanyar kare kariya
Ka'idojin ikon lantarki
Eddy na yanzu an {{0 0 Lokacin da mai canzawa ke gudana, filin magnetic filin zai haifar da Eddy na Eddy a cikin waɗannan kayan wasan. A cewar dokar Lenz, 'yan kwalliyar Eddy za su samar da filin magnetic a gaban shugabanci na farko Filness. Wannan filin na jutani na Magnetic na iya kashe wani ɓangare na asali na magnetic, ta haka ya raunana filin magnetic kuma yana rage zubar da filin magnetic ta hanyar tashar jiragen ruwa mai.
Tsakanin filin lantarki da caji na lantarki: bayan garkuwar lantarki, yana iya dakatar da filin lantarki a saman mai gudanarwa. Saboda filin lantarki da aka samar da babban {{1} Wa zai iya shigar da caji a saman mai garkuwa, da kuma hana filin lantarki daga tashar jiragen ruwa ta hanyar tankar mai.
Babban bambanci tsakanin garkuwar Magnetic da lantarki za'a iya samo asali ne daga tasirin tseren magnetic. Lokacin amfani da garkuwar Magnetic, duba Hoto na 3, babban hanyar tsinkaye magnetic frix shine tsawo na iska da iska tsawon hanyar radial. Kayan kayan cin abinci suna da ƙarancin tsari game da rarraba magnetic saboda babban ƙarfin magnetic. Daga hangen nesa na Magnetic Circuit da Magnetic Fiel, ana iya ɗauka cewa rarraba juzu'in Magnetic shine ƙayyadadden bincike na magnetic junetic. Dingara giyarwar Magnetic a cikin tanki mai a cikin ƙasa ba ya shafar rarraba fasahar magnetic.
Wannan kuma shine batun a zahiri. Gwaje-gwajen sun tabbatar da cewa amfani da garkuwar Magnetic ba shi da tasiri a kan gajeren- acppique rashin daidaituwa na juyawa na magnetic bai canza ba; Koyaya, yin tsallake magnetic filin kariya daga gidan yanar gizo kusa da babban jigon yanzu ya bambanta. Bayan ƙara kare kariya zuwa bango mai mai, Eddy na yanzu halin da ke kare tsinkaye Magnetic ya haifar, rage yaduwar maganadita na yanzu. Wannan wani tsayayyen ampere {{4} juya Filin Magnetic, kuma Eddy na yanzu yana rage raunin magnetic frix.
Aika Aikace-aikacen