Mai canzawa 2500 Kva-13.2 / 0.6 KV|Amurka 2026
Yawan aiki: 2500 kVA
Wutar lantarki: 13.2/0.6 kV
Feature: bayyane taga
Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'anta da masu samar da taswira 2500 kva{6}}13.2/0.6 kv|Amurka 2026 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

Ƙaƙƙarfan bayani na rarraba don nan gaba- pad wanda aka ɗora tafsiri: lafiyayye, kuzari{1}} inganci, kuma mai dorewa.
01 Gabaɗaya
1.1 Bayanin Aikin
2500 kVA three phase pad mounted transformer an isar da ita zuwa Amurka a shekarar 2026. Ƙarfin wutar lantarkin shine 2500 kVA tare da sanyaya KNAN. Babban ƙarfin lantarki shine 13.2GrdY / 7.62 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.6Y / 0.347 kV, sun kafa ƙungiyar vector na YNyn0.
Lokacin da wani abokin ciniki mai amfani da wutar lantarki na Amurka ya tunkare mu tare da buƙatar ingantaccen, ingantaccen 2500 kVA guda uku -kushin lokaci{4}} wanda aka ɗora tasfoma, mun san cewa mafita dole ne ta wuce daidaitaccen rukunin kasida. Abokin ciniki ya buƙaci na'ura mai canzawa wanda ya dace da takamaiman aiki, muhalli, da buƙatun aminci{6}} da SCOTECH da aka kawo.
Abokin ciniki -Kwararren Ƙwararru
Aikace-aikacen abokin ciniki ya buƙaci na'ura mai canzawa wanda zai iya ɗaukar yanayin nauyi mai wahala yayin da yake tabbatar da dogon lokaci{0}, yarda da muhalli, da sauƙin sa ido. Dangane da cikakkun bayanai dalla-dalla, SCOTECH ya ƙera kushin kVA 2500 - wanda aka ɗora tasfoma tare da fasali na musamman masu zuwa:
• FR3 Dielectric Fluid - Mai yuwuwa mai lalacewa, mai girma{1}}wuta{2}}point ester{3}}mai tushe, wanda aka zaɓa don ingantaccen bayanin muhallinsa da ingantaccen amincin wuta, mai kyau don shigarwa kusa da wurare masu mahimmanci.
Babban inganci - 99.39% - Ingantacciyar ƙira da ƙira don rage asara, rage farashin aiki da tallafawa burin ingantaccen makamashi na abokin ciniki.
• BIL 110 kV - Matsakaicin matakin rufe fuska mai ƙarfi wanda aka ƙididdige shi a 110 kV, yana tabbatar da ƙaƙƙarfan kariya daga hawan wutar lantarki da abubuwan walƙiya.
• Babban -Voltage 600A Bushings – Nauyi masu nauyi{2} da aka ƙera don ingantaccen haɗin kai{3}} na yanzu, dacewa da ƙayyadaddun grid na abokin ciniki.
Garkuwar Electrostatic - Garkuwar wutar lantarki tsakanin firamare da na biyu windings don murkushe wuce gona da iri da inganta ingancin wutar lantarki.
• Window dubawa - Tagar dubawa mai dacewa don saka idanu na gani na matakin mai da yanayin ciki ba tare da buɗe tanki ba.
• Mita uku da Bawul ɗaya (tare da Lambobi) - Cikakken sa ido da fakitin kariya:
Babban ma'aunin zafi da sanyio mai
Ma'aunin mai
Ma'aunin matsa lamba
o Na'urar taimako na matsa lamba (tare da lambobin lantarki don ƙararrawa / tafiya mai nisa)
• Akwatin Tasha - Akwatin tasha mai haɗaka don aminci, tsara wayoyi da haɗin kai.
• Masu kama da yawa - Gina{0} a cikin masu kamawa don kare na'urar wuta daga walƙiya da kuma sauyawa.
• Launin Fenti: Koren Zaitun (RAL 6003) - Na al'ada{1}} fentin don dacewa da ƙayyadaddun ƙayyadaddun ƙayyadaddun kayan ado da kayan haɗin muhalli na abokin ciniki.
1.2 Ƙayyadaddun Fasaha
2500 kVA kushin da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai
|
Isarwa zuwa
Amurka
|
|
Shekara
2026
|
|
Nau'in
Tashin wutar lantarki
|
|
Daidaitawa
IEEE Std C57.12.34-2022
|
|
Ƙarfin Ƙarfi
2500 kVA
|
|
Yawanci
60HZ
|
|
Mataki
3
|
|
Ciyarwa
Madauki
|
|
Gaba
Matattu
|
|
Nau'in Sanyi
KNAN
|
|
Babban Voltage
13.2GrdY/7.62kV
|
|
Na biyu Voltage
0.6Y/0.347 kV
|
|
Abubuwan Iska
Aluminum
|
|
Ƙungiyar Vector
YNyn0
|
|
Impedance
5.75%
|
|
inganci
99.39%
|
|
Matsa Canji
Farashin NLTC
|
|
Taɓa Range
±2*2.5%
|
|
Babu Asara Load
3.6 kW
|
|
Akan Rasa Load
17.8 kW
|
1.3 Zane
2500 kVA kushin da aka ɗora zane da girman hoto.
![]() |
![]() |
02 Masana'antu
2.1 Kori

Wannan naúrar tana ɗaukar ƙirar ainihin ƙafar ƙafa uku{0}}, biyar{1}, an inganta ta hanyar lantarki don ajin ƙarfin 2500 kVA da mitar aiki 60 Hz. Tsarin kafa guda biyar- yana taimakawa wajen rage tsayin tushe da haɓaka rarrabuwar ruwa, daidaitawa babu- lodi da hasarar lodi yayin da suke riƙe rashin ƙarfi na 5.75% da X/R=8. An yi iskar da injin madubin aluminum, an haɗa shi da ±2 × 2.5% de-madaidaicin wutar lantarki na abokin ciniki na farko da ake buƙatar canjin wutar lantarki na abokin ciniki 13.2GrdY/7.62kV. Ƙarfin da aka auna ya kai kashi 99.39%, yana sanya wannan rukunin a matsayi mai girma tsakanin masu rarraba wutar lantarki.
2.2 Tanko
Tankin ginin ƙarfe ne mai laushi da aka rufe tare da murfi da aka kulle don samun damar kulawa. Ruwan da ke hana ruwa shine FR3 man ester na halitta - mai iya lalata, shuka -madaidaicin ruwan dielectric tare da filasha kusan ninki biyu na mai na ma'adinai, yana ba da mafi girman matakin amincin wuta. Don pad - na'urorin lantarki da aka sanya a wuraren jama'a ko wuraren da ba su dace da muhalli ba, man FR3 yana ba da fa'idodi masu mahimmanci a cikin yabo da sarrafa haɗarin gobara. An fentin na waje a cikin Green Green (RAL 6003) don kariyar lalata da daidaitawar gani. Ana ba da tagogi na gani a duka manyan ɗakunan wutan lantarki da ƙananan{11}, suna ba da damar lura da matakin mai na ciki da matsayin aiki ba tare da buɗe tanki ba.

2.3 Garkuwar Electrostatic
Ana sanya garkuwar wutan lantarki tsakanin iskar firamare da sakandare don murkushe wuce gona da iri ta hanyar iyawar da aka rarraba. Ana fitar da garkuwar ta hanyar shingen garkuwar ƙasa mai sadaukarwa kuma an kafa shi da ƙarfi a cikin ƙaramin rukunin wutar lantarki. Wannan ƙira yana taimakawa wajen karkatar da motsin walƙiyar walƙiya ko jujjuya overvoltages zuwa gefen lodi na biyu, yana ba da kariya mai ma'ana ga nauyi mai mahimmanci.

2.4 Mita uku da Bawul ɗaya tare da Lambobi

Kunshin sa ido da kariya an haɗa shi azaman tsarin "mita uku da bawul ɗaya" ta kowane buƙatun abokin ciniki:
• Babban Ma'aunin Ma'aunin Mai: tare da lambobi 2, don kula da yanayin zafin mai da fitowar siginar ƙararrawa / tafiya;
• Matsayin Matsayin Mai: tare da lamba 1, yana ba da ƙararrawa mai ƙarancin mai;
• Ma'aunin Matsala na Vacuum: tare da lambobin sadarwa 2, kula da yanayin matsa lamba na ciki;
• Na'urar Taimakon Matsi: Nau'in zobe{0}, don amintaccen taimako na matsi a ƙarƙashin yanayi mara kyau.
Ana iya tura duk siginar tuntuɓar zuwa akwatin tashar don sauƙaƙe haɗin kai tare da SCADA ko tsarin kariya na abokin ciniki.
2.5 HV 600A Bushing da HV Neutral Bushing
Gefen farko na amfani da 600 A na haɗe-haɗen bushings na HV, adadi 6 (mai shigowa da mai fita uku), an saka su a cikin ɗakin HV. Waɗannan ɓangarorin sun haɗu da daidaitaccen ƙirar IEEE Std 386 kuma ana ƙididdige su don ajin 15/25 kV, 600 A ci gaba na yanzu, tare da ɗan gajeren lokaci - juriya na 25 kA/0.17 s ko 10 kA/3.0 s. Ana fitar da wurin tsaka tsaki na HV daban ta hanyar bushing tsaka tsaki na HV azaman tashar H0 don amfanin abokin ciniki.

2.6 Nitrogen Valve
Ana samar da bawul na nitrogen (bargon nitrogen) akan tanki don kiyaye yanayin da aka rufe-. Bargon nitrogen yana keɓe ruwa mai hana ruwa daga hulɗar iska, yana jinkirta iskar gas, kuma yana kula da matsi mai kyau, yana taimakawa wajen adana aikin dielectric na dogon lokaci.
2.7 Akwatin Tasha

An haɗa akwatin tasha akan tanki don tattara siginar lamba daga mita uku da bawul ɗaya, jagorar garkuwar ƙasa, da sauran igiyoyin sarrafawa. Wannan tsari yana sauƙaƙe hanyoyin sadarwa na fili, canja wurin sigina, da kiyayewa na gaba, guje wa bayyanar da igiyoyi na biyu kai tsaye zuwa yanayin waje.
2.8 Mai Girma Mai Kama
Ana shigar da masu kamun ƙwanƙwasawa, adadin 3 (ɗaya a kowane lokaci), a gefen HV don iyakance walƙiya da jujjuyawar wutar lantarki da ake amfani da su zuwa iskar taswira. Matsayin hawan mai kamawa da hanyar ƙasa an haɗa su cikin ƙira don ba da kariya ta haɗin gwiwa a matakin rufewa na BIL 110 kV / AC 34 kV.

2.9 HV da LV Grounding Bars
Ana ba da sandunan ƙasa a duka ɗakunan HV da LV, suna ba da wuraren haɗin ƙasa na tsakiya don shinge, tsaka tsaki, masu kamawa, da garkuwa. An saita adadin ramuka ta kowane buƙatun abokin ciniki don ingantaccen haɗin haɗin kai na filin filin.


03 Gwaji
Wannan 2500 kVA guda uku -kushin lokaci{2}} da aka ɗora tafsiri (Serial No. 260701-1) ya kammala duk gwaje-gwaje na yau da kullun daidai da IEEE Std C57.12.34-2022 da IEEE C57.12.90-2021. Kwanan gwajin ya kasance Agusta 14, 2026, a yanayin zafi na digiri 33 da ɗanɗano zafi na 60%. An taƙaita sakamakon a ƙasa:
• Ma'aunin Juriya: Matsakaicin juriya rashin daidaituwa na iskar HV shine 3.89%, saduwa da daidaitattun buƙatun; An auna rashin daidaituwa na LV kuma an sami karɓuwa.
• Gwajin Ratio da Mataki {{0}Gwajin alaƙa: Matsalolin ƙarfin lantarki akan babban bugun ta shine 0.04%, mafi kyau fiye da ƙasa ko daidai da buƙatun karɓa na 0.5%; sabawa a duk wuraren famfo suna cikin iyakoki masu izini. Ƙungiyar vector da aka auna ita ce YNyn0, daidai da ƙimar ƙira.
• A'a -Asar Load da A'a{1}}Loadyar Yanzu: Ƙa'idar babu{2}} asarar nauyi shine 3.30 kW (a digiri 20 ), kuma babu - load halin yanzu shine 0.25%, dukansu sun cika ingantattun ƙimomi.
• Load Losses, Impedance Voltage and Efficiency: At 85℃and rated voltage, the measured load loss is 17.70 kW, total loss is 21.00 kW, and the measured short-circuit impedance is 5.47% (guaranteed value 5.75%, within ±7.5% tolerance). Ƙimar da aka auna shine 99.42%, wanda ya zarce garantin kwangila na 99.39%.
• Gwajin wutar lantarki da aka Aiwatar: 34 kV / 60 s an yi amfani da su zuwa gefen HV da 10 kV / 60 s zuwa gefen LV. Babu rushewar wutar lantarkin gwajin da ta faru; juriya na rufi abin karɓa ne.
• Gwajin Jurewar Wutar Lantarki: Aiwatar da ƙarfin lantarki 2Ur, jawo 2 da yawa, mitar 200 Hz, tsawon 36 s. Babu rushewar wutar lantarkin gwajin da ya faru.
• Ƙimar Ƙarfafa Ƙarfafawa: HV zuwa LV da ƙasa 1.13 GΩ; LV zuwa HV da ƙasa 1.17 GΩ; HV & LV zuwa ƙasa 0.619 GΩ. Yanayin rufewa yana da kyau.
• Gwajin Leak: Hanyar matsa lamba a tsaye a 50 kPa na awanni 24. Babu yabo kuma babu nakasu na dindindin; aikin hatimi abin karɓa ne.


04 Shiryawa da jigilar kaya
4.1 Shiryawa


4.2 Shipping


05 Yanar Gizo da Takaitawa
Wannan 2500 kVA pad{1} da aka ɗora tafsiri yana wakiltar ikon SCOTECH na juya buƙatun abokin ciniki zuwa hanyoyin samar da wutar lantarki masu inganci, abin dogaro, da musamman na musamman. Ko don rarraba kayan aiki, haɗakarwar makamashi mai sabuntawa, ko aikace-aikacen masana'antu, SCOTECH ta ci gaba da jajircewa wajen isar da taswirar da suka dace da ainihin bukatun kowane abokin ciniki{3} cikin aminci, da inganci, kuma akan lokaci.
SCOTECH - Abokin Hulɗar ku a cikin Maganganun Canji na Musamman.

Hot Tags: mai canzawa 2500 kva-13.2 / 0.6 kv|usa 2026, taransfoma na kasar Sin 2500 kva-13.2/0.6 kv|usa 2026 masana'antun, masu kaya, masana'anta
You Might Also Like
2000 kVA Kushin Dutsen Mai Canjawa-25 / 0.6 kV|Kanad...
300 kVA Kushin Haɓaka Masu Canjin Lantarki-34.5 / 19...
1000 KVA Mai Canza wurin zama Akwatin-22.86 / 0.208 ...
2500 KVA Madaidaicin Ciyarwar Mai Canjawa-12.47*24.9...
1000 KVA Bess Mai Canjawa -34.5 / 0.48 KV|Amurka 2026
2000 KVA Delta Wye Transformer-34.5 / 0.48 KV|Amurka...
Aika Aikace-aikacen