Menene GIS? Jagora ga gas infulated Canzime vs Ais

Jun 24, 2025

Bar sako

Menene GIS?

 

 

Gas Insulated Switchgear Cikakken sunan shi ne gas mai canzawa. Gas gas infulated anan yana nufin sulfur hexflumide (SP6). Subsia ne raguwa na haɗuwa da 'yan tawaye, ƙasa, canzawa, masu watsa labarai, masu shiga tsakani, masu haɗawa da tashoshin masu fita. Wadannan na'urori ko abubuwan da aka haɗa a cikin casan karfe, kuma suna cike da sf6 insulating gas a wani matsin lamba, don haka ana kiran shi Sf6 cikakken kewayon hade hade. Don haka, gi ya haɗu da babban {7} octage kayan lantarki a cikin tsarin lantarki gwargwadon ƙarfin ƙarfe na SF6 tare da filaye na lantarki na SF6 tare da ingantaccen rufi na sf6 da {9} blontani subchgaar.

 

Halaye na Sf6

gas sf6

SF6 shine mafi yawan iskar gas da aka haife shi a Faransa. Gas mai tsabta sf6 ba shi da launi,

Ba shi da daɗi, ƙanshi ba shi da kamshi, ba {0- {ermable, kuma yana da tsayayyen kaddarorin sinadarai a zazzabi a ɗakin zazzabi. Isarshen iska ne. Yawan gas shine sau 5.1 da iska.

Gas na SF6 yana da ƙarfin sayan kayan aiki daidai gwargwadon ƙarfin mai canzawa a matsin lamba na 0.29 MPA, kuma ikon da aka kashe ta Arc da ke cikin iska. A halin yanzu an fi amfani da iskar gas din da aka fi amfani da iskar gas.

 

Kwatantawa tsakanin AIS da Gis

air insulated switchgear gas insulated switchgear
Subche iska Gas da keyulated Sypear

 

1. Sarari bene

Floor Space of Gas Insulated Switchgear GIS, wani babban kunshin karfe tare da tsarin karamin abu, yana mamaye kashi 10% na sararin samaniya na AIs na 500kv gis. Wannan shine dalilin da ya sa gi ya fara ne a wuraren da ake buƙatar ƙasa, kasancewa da yawa yana da kyau sosai, Wurin ƙasa suna da girma sosai. Tabbas, wannan baya nufin cewa ƙasa ita ce kawai saɓon zabar GIS. Akwai wasu dalilai da yawa, kuma wannan ɗayansu ne.

 

2.

altitude

Dangantaka tsakanin tsayi da ƙarfin yankeale:

Kamar yadda hankali yana ƙaruwa, matsin lamba na atmoshheric ya ragu sosai, sakamakon shi ya ragu cikin yawa. Iskar ta zama "bakin ciki". Iyakar jirgin sama na iska (iyawar sa don tsayayya da rushewa da hana yin sarrafawa) ya dogara ne kai tsaye akan yawan sa. Air tare da ƙananan yawa (babban tsayi) yana da mafi girman kwayoyin halitta da kuma mafi tsayi kwayoyin halitta. Wannan yana sauƙaƙa wa wutan lantarki a hanzarta a filin lantarki kuma ku sami isasshen makamashi don tuntuɓar da iunin wasu kwayoyin. Sabili da haka, a irin ƙarfin ƙarfin guda, rufin filayen iska a babban alt ttitudes yana da ƙasa da wannan a matakin ƙananan altitudes ko matakin teku.

Lokacin da aka shigar da sawagthear a cikin wani mafi girma ƙarfin, matsakaicin ƙarfin lantarki yana iya tsayayya ba tare da an rage shi ba, don haka matsakaicin ƙarfin lantarki wanda zai iya yin aiki mai lafiya. Wannan shine dalilin da ya sa, don iska na al'ada {{1} etpular Subai, idan ana buƙatar shigar da mita sama da mita 1000, kayan aiki tare da mafi girman ƙarfin allura. GIS kariya daga gas na SF6, don haka ba za a iya hana shi da tsauni ba.

 

3. Tsaro

safety

Dangane da aminci, duk babban {{0} {0} octage an rufe su a cikakkiyar ƙwanƙwasa ƙarfe wanda ke ƙasa. Casing yana samar da garkuwar lantarki na halitta (tasodin almara), kuma ko da an shafe casing kai tsaye lokacin da kayan aiki ba zai faru ba, cimma kariyar tsaro ba za ta faru ba, cimma kariyar tsaro ba za ta faru ba, cimma kariyar tsaro ba za ta faru ba, cimma kariyar tsaro ba za ta faru ba, cimma kariyar tsaro. AIS ya yi amfani da wani tsari na bude, kuma babba - operage mai sarrafa kansa ne kai tsaye fallasa zuwa iska. Lokacin aiki ko gabatowa da gangan, ma'aikata dole ne ya kula da nesa mai aminci (yawanci fiye da na mita da yawa). Akwai haɗarin haɗari na ba da izini na kayan aiki ba, kuma shingen warewa da kuma ƙayyadaddun kayan aiki dole ne a dogara don kariya.

Amma wannan baya nufin AIS ba shi da lafiya ko kuma amintacce. A zahiri, kashi 70% na canjayyan duniya suna kunshe da fasahar Ais. Tsabtace nazarin na yau da kullun na insulators, shigarwa na na'urorin karawar da tsuntsaye, kuma a {{3} Kayan kayan aiki na iya kula da aiki.

 

4. Fadada canzawa

A lokacin da ke zayyana abubuwa, injiniyoyi yawanci suna ajiye yankin ƙasa don biyan bukatun nauyin nauyin zai rage gaba. A cikin iska - ire-enulated kayayyaki (AIS), wannan fadada yawanci in mun gwada kai tsaye da sassauƙa. Tun da kayan aiki na AIS (kamar kayan fashewa, masu canzawa, masu canzawa, busasshiyar shigarwa, galibi yana buɗe {4} etction a cikin rufin iska da rarrabuwa tsakanin juna. Dingara sabon Bays ko kuma shimfida busassun yawanci suna buƙatar shigar da sabbin raka'o masu daidaitattun kayan aiki a cikin sarari da aka ajiye kuma suna tabbatar da isasshen hanyar lantarki. Akwai kasa da dogaro kan takamaiman samfurin ko mai kera sabon kayan kara. Kayan aiki na samfurori daban-daban ko samfura (muddin suna saduwa da sigogi na sigogi) ana iya haɗa shi cikin tashoshin da ake ciki ko gudu a layi daya.

 

Koyaya, gas {{0 {0 {0 {0 inpsulated possion (gis), fadada ya fi rikitarwa kuma ya dogara da takamaiman masana'antun. Wannan saboda GI GI ya haɗu da girma {2} - ne da kuma sauya su a cikin gidaje na m karfe cike da isasshen gas (kamar Sf6). Fadada yawanci yana nufin sabon, isasshen matattara -}} awo dole ne a ƙara kayan sararin samaniya. Wadannan kayayyaki suna buƙatar yin matuƙar jituwa tare da kayan aiki masu gudana, ke dubawa (kamar saiti), masu haɗin gas, da sa ido da kuma kula da tsarin sarrafawa. Wannan buƙatun da ya dace ya sa kusan ya zama dole don amfani da takamaiman kayan ƙira na mai ƙira ɗaya, ko ma jerin kayan aiki na yau da kullun don tabbatar da nasarar Airthightess, rufi da haɗin gwiwa da haɗin gwiwa da haɗin gwiwa. Sabili da haka, tsarin fadadawar GIS yana dogara sosai akan zabin ɗan lokaci kuma tsawon {{{10} Taimako na mai masana'anta.

 

5. Kariyar muhalli

 

environmental protection A cikin sharuddan kare muhalli, AIS da Gis suna da nasu fa'idodinsu da rashin amfanin su. AIS yana amfani da rufin iska kuma baya haɗuwa da iskar gas. Idan aka kwatanta da gas na Sf₆ da aka yi amfani da shi a cikin gig, yana da ƙarancin tasiri a kan yanayin, musamman wajen sarrafa tasirin greenhouse. A lokaci guda, tsarin AIS yana da sauƙi, wanda zai sauƙaƙe ganowa kuma ya sake dawowa lokacin da aka yi ritaya, kuma yana da nauyin muhalli mai sauƙi. Koyaya, Gis ya fi tsabtace muhalli yayin gini da aiki. Ya mamaye ƙaramin yanki kuma ya dace da ƙasa {{5} ired wuraren da birane. Yana da ɗan gajeren lokaci kuma yana haifar da ƙima. Tsarin rufafful wanda ya dace yana rage hayaniyar aiki kuma yana da tsewa daga yanayin kewaye. Saboda haka, AIS, AIS ya fi aminci a cikin tsabtace kayan greenhouse, yayin da Gis ya yi mafi kyau a cikin ceton ƙasa, ragi da tasiri. Tare da ci gaban sabon fasahar gas mai aminci, ana sa ran Halin GIS zai ci gaba da inganta a nan gaba.

 

 

6. Kudin

Kudin siyan AIS na kayan aiki kusan 30% {- 50% na GIS, wanda ya ƙunshi fa'idar farashi. Landasar ƙasa tana da mahimmanci: isassun nesa mai aminci na lantarki yana buƙatar an tanadi nesa don abubuwan da ke fallasa, sakamakon shi ne babban yanki. A cikin biranen birni ko kuma shirye-shiryen ƙimar ƙimar, kuɗin ƙasa na iya wuce kayan aikin kayan aiki. Teburin mai zuwa shine kwatancen farkon hannun jari na farko, farashin aiki da kiyayewa, da kuma farashin sake zagayowar AIS da Gis.

Gwadawa AIS Gis
Zuba Jari Kudin kayan aiki (kimanin 30% -50% na GIS) farashin ƙasa Kudin kayan aiki (gami da gas na Gas / sf₆ Gas) ƙasa ajiyan 50-70%
Aiki da kiyayewa Akwatin tsabtace na insulators Anti {{0} {{- {Actions kayan aiki saka jari Ainihin, kiyayewa - ire mai lura da Sf₆ Gas shine babban farashi
Cikakken Tsarin Rayuwa Low bakin motsa jiki, mai sauki amma ci gaba da tabbatarwa Za'a iya rage yawan saka hannun jari na farko, ana iya rage farashin aiki da 40% + cikin shekaru 20

 

 

Aika Aikace-aikacen