Mai ganowa (mai gano kuskure na ciki) a cikin Ba'amurke {{0} Kadawar kayan aiki {1} 1 Zai iya gano yanayi mai haɗari don tabbatar da amincin kayan aikin. A kasa cikakken bayani ne.

IFD

Fasali mai aiki

 

  • Kulawa da La'adawa: Gaskiya - Kulawa da al'amuran canzawa na ciki kamar sujirori, zazzabi mai mai zafi, da kuma mafi ƙarancin matakan mai.
  • Amsar da sauri: Da sauri ta ba da ƙararrawa ko ka'idojin kulawa (misali, saƙo sauye sauye) akan gano mahaitattun masana.
  • Sarrafawa ta atomatik: Wasu ifds zasu iya hulɗa tare da wasu na'urorin kariya don ware kayan aiki ta atomatik.
  • Tsawo {{0} kwanciyar hankali na lokaci: An tsara don dogaro da aminci da kuma dacewa da yanayin zafi na waje (misali, babban yanayin zafi, zafi, gas mai lalacewa).

Internal Fault Detector

 

 

Abubuwan tsari na tsari

 

  • Firikwensin sensor:

○ na'urorin zazzabi: Ayyukan maimaitawar mai da yanayin zafi mai iska.

○ Manyan Manyan Gas: Gano canje-canje na maida hankali a cikin gas da narkar da (misali, hydrogen, methane) a cikin mai.

  • Lissafi: Saka idanu canje-canje a cikin matsin lamba na ciki.
  • Naúrar sarrafa siginar: Binciken data tattara ta hanyar na'urori masu auna na'urori don sanin yanayin kuskure.
  • Kararrawa da naúrar aiki: Batutodiddigar sauraro da alamu na gani ko aika sakonnin sarrafawa don sarrafa na'urorin.
  • Kuntawa: Yana watsa bayanai don lura da cibiyoyi ta hanyar Rs485, GPRS, Ethernet, da sauransu.

 

 

 

Shigarwa da Matsayi

 

  • Galibi ana hawa a gefe ko a cikin shinge na shinge.
  • Haɗa tare da tanki, tsarin sanyaya, da haɗin lantarki.
  • Sanya don sauƙaƙe mai sauƙi da dubawa ba tare da dakatarwar zafi ba.

IFD of transformer

Tsarin aiki

 

  • A yayin aiki na al'ada, da IFD rikodin bayanai.
  • Idan ta gano zazzabi mai wahala ya tashi, yana canzawa kwatsam na kwatsam, ko tarawa, yana haifar da faɗakarwa ko kunna hanyoyin kariya.
  • Ci gaba idan an yi amfani da shi- A cikin algorithms don nazarin abubuwan data, hango maƙasudin kurakurai, da kuma samar da shawarwarin tabbatarwa.

 

Abvantbuwan IFD na IFD a Pad - ya sanya masu canzawa

 

  • Aiki mai hankali: Rage mijin hannu na manual da kuma inganta martani mai martaba.
  • Cikakken Lake Ciki: Takaitaccen isar da gajere da ƙarancin kuɗin da ke ƙasa.
  • Gudanarwar nesa: Yana ba da damar sarrafa aiki kuma yana inganta aiki mai aiki.
  • Manta kayan aiki na LifeSpan: Yana rage ragi na lalacewa ta hanyar tantance na Transnd da Tsinkaya.

 

IFD tana tabbatar da amincin Amurka {{0} Kadawar salon {{1} {{1} ireformers, rage mita da kwanciyar hankali.