Takaitaccen bayanin canji naúrar
Sep 23, 2025
Bar sako

I. Gabatarwa
Ana amfani da injiniya da haɓaka ƙira, mafi girman masana'antu na Scotech don cika da yawa na ƙayyadaddun kayan ciniki. Suna isar da juyawa da iko da kuma rarraba yayin da suke ba da gudummawa sosai don samar da amincin Arc Flash da haɓaka mahimmancin muhalli.
Kowane mai canzawa zai iya zama cikakke dangane da yanayi na musamman na musamman, faɗakar shafin, da kuma buƙatun wuri. Ruwa-garwa da yawa {{1} kamar murfin - wanda aka ɗora- don sauƙaƙe haɗin haɗin gwiwa tare da tsarin farko da / ko tsarin sakandare.
Scotech masana'antu masu canjin sa a cikin ingantaccen ka'idodin kasa da kasa da {{00, kamar yadda ya dace da kasawa ta duniya.
II. Shiri


III. Rarrabuwa


IV. Aikace-aikace
Canjin naúrar taúrar taúrar taúrar ta zama babban taro ne wanda ya hada matsakaici {{0 Babban aikinta shine canza kuma ya raba iko a gida don ɗaukar nauyi.

1. Masana'antu masana'antu
Ikon kayan masarufi, layin samarwa, da motocin sunadarai a masana'antar, sunadarai sunadarai, da kuma masu girki ta hanyar samar da canjin wutar lantarki kusa da cibiyar kaya.

2. Gilashin kasuwanci
Yana aiki a matsayin babban zuciyar wutar lantarki don manyan gine-gine kamar Skyscrapers, kantuna, da kuma rarraba iko ga haske, masu haɓaka, da tsarin hvator.

3. Kayan aikin jama'a
Yana tabbatar da ingantaccen iko ga mahimman wurare masu mahimmanci kamar fil filastik, tsire-tsire masu magani, tsarin dogo, da kuma taron jama'a.

4. Shukewar kuzari mai sabuntawa
Amfani da shi azaman "tarin iko da mataki {{0} Up naúrar" A iska da rana da rana na hasken wuta don haɓaka ƙarfin lantarki zuwa matakin da ake buƙata don haɗin Grid.

5. Cibiyoyin bayanai
Yana bayar da ingantacciyar abin dogaro, babba - {Haske mai inganci don garken na Server ɗin, yana haifar da farkon tsarin rarraba bayanan bayanan.

6. Saukowa da hakar
Yana kawo makoki da kuma fashewar fashewar {{0} Powerarfin hujja a cikin mahalli na minorments don sarrafa kayan aiki kamar ma'aikata.
V. Abubuwan da aka gyara V.

1. Bect Willet akwatin
An yi amfani da shi don shigar da sigina na yanzu na busharar transforers na yanzu (bct), yana ba da ƙarin girman {0} Voltage Side na yanzu da kuma watsa siginar kariya.

2. Bakin sarrafawa
Majalisar ta haɗa da kayan aikin sarrafa mai canzawa, wanda zai iya gane farawa {{0} dakatar da sarrafa kayan aiki kamar magoya baya kamar maganganu, da kuma aiki da matsayin aikin sa ido.

3. CT Box
Kamfanin kariya na kariya musamman don shigar da masu canzawa na yanzu (CT), wanda ke kare CT, ya tsara Wiring na lantarki, kuma ya mallaki da'irorin lantarki.

4. Rana bawul tare da samul
Bawul tare da duka magudanar mai da ayyukan mai. Zai iya samar da mai mai canzawa yayin kulawa da kuma fitar da samfuran mai ga ingancin mai.

5. Magoya baya
Wani sabon abu mai sanyaya na mai canzawa. Yana farawa ta atomatik ko da hannu lokacin da mai zazzabi ya tashi, haɓaka ingancin yanayin radiator ta hanyar iska mai ƙarfi a cikin al'ada.

6. Hv Bushing (babba {{{1} ~}
Wani tsinkaye haɗin haɗin haɗin a kan babba {{0} gefen lantarki. Ontaya daga cikin ƙarshen an haɗa shi da babban abu {{2} Village yana yawo daga mai canzawa, kuma ɗayan ƙarshen ƙarfin lantarki, yana haifar da babban ƙarfin lantarki daga kwasfa.

7
Wani keɓaɓɓiyar kayan haɗin akan low {0} options, tsarin rarraba wutar lantarki, sanin ingantaccen fitarwa {{{3} occage a halin yanzu.

8. Name
Farantin ƙarfe alama da mahimman sigogin mai canzawa, gami da maballin maballin, daukakiyar ƙarfin lantarki, ƙimar wutar lantarki, mai ƙera, da ranar samar da kayayyaki.

9. Mai nuna mai
Na'urar da ke cikin hikima tana nuna matakin ruwa na insulating mai a cikin tanki mai juyawa, taimaka aiki da kuma hana laifin da ƙarancin mai.

10. Na'urar Ciniki
Aikin aminci wanda zai iya sakin matsin lamba da sauri lokacin da matsin lamba a cikin tanki mai ke tashi.

11.
Wani nau'in na'urar ba da taimako na taimako wanda ke daidaita matsin lamba ta hanyar budewa da rufewa daga bawul. Yana buɗewa don sakin matsin lamba lokacin da matsin lamba ya wuce darajar saiti kuma zai iya sake saitawa bayan matsin lamba ya koma al'ada.

12. RADIOT
Babban kayan zafi na zamani na mai canzawa. Yana kara yankin lambar sadarwa tsakanin mai da iska ta hanyar bushe dissipation, kyale zafi na insulating mai da za a watsar cikin iska da rage yawan zafin jiki.

13. Daidaita tashin hankali
Abubuwan kariya wanda ke lura da raguwar matsin lamba a cikin tanki mai. Idan matsin yana tashi da sauri (mafi yawa alama alama ce ta gazawar ciki), nan da nan ta haifar da siginar kariya ko kuma aiki.

14. Matsa canzawa
Wani bangaren da ke daidaita lokacin ƙarfin lantarki na mai canjin. Yana canza yawan wutar iska ta hanyar canza famfo na iska, rama don dutsen na wutar lantarki, kuma yana tabbatar da wutar lantarki mai tsayayye.

15. Mai nuna alamar zazzabi
Na'urar da ke lura da zazzabi na insyulating man a cikin tanki mai canzawa, yawanci tare da sikeli ko nuna alamar dijist ko nuna alama ga yanayin zafin mai.

16
Bawul ɗin mai cike yake a saman tanki mai, wanda aka yi amfani da shi don cika mai canzawa ko ƙarin infuling matakin a cikin aiki.

17. Na'urar matsin lamba
Ana amfani da na'urar Axilius galibi ana amfani dashi yayin juyawa mai cike da mai ko kiyayewa. Zai iya fitar da iska daga tanki mai don samar da wani matattara, guje wa kumfa na iska wanda aka gauraye a cikin aikin rufewa a cikin tanki mai.

18. Mai nuna alamar zazzabi
Na'urar da ke lura da zafin jiki na canja wurin iska. Yana nuna halin dumama na iska ta hanyar zafin mai da kuma ɗaukar juyawa na yanzu ko kuma ma'aunin kai tsaye, kuma yana da tushe don yin hukunci ko iska mai zafi yana da zafi.
Vi. Ka'idodi & na zaɓi
Tabbatattun abubuwa
- Yarjejeniyar asali: Haɗu / ya wuce Ansi / Ieee / CSA / IEC; Ul {{{0} +
- Tanki: Karfafa gashi mai laushi (Cikakken mitafi- ► Rated don manyan raka'a); Tare da pads na ƙasa, dagawa matakan hawa, skid / boots; Baƙon karfe; radiators / mahaɗan + + kunshin fan.
- Bas: Cover / Seedwall - ya sanya (LV: EPOXY / COURSELE DA NEMA SOMA SOMA); HV / LV a waje ya matsa lamba; murfin madauwari / madauwari coils; bashin waje na waje.
- M: Babu - Ma'adin Ma'adin PCB.
- Guges / na'urori: Mallafa mai zane-zane, matsin lamba, na'urar ba da taimako, mai / ma'aurata / matakan matakin.
- Balves / Matruts: 1 "Cika filogi, graaded magudanar / samfurin bawuloli (by KVA), CVaukar ruwa mai rufi, Birni / Radiat Headter Badves.
- Matsa Canja: De {{{{0} to} iyar aiki; Oltc + Nltc.
- Kaya: Silicon - iren karfe, iska mai laushi; Mai gudanarwa mai Corrous - mai tsatsawa nameplate.
- Wasu: Furannin ƙasa, bargo na nitrogen; 505 Digiri na digiri na sama
Abubuwan Zabi na Zabi
- Tanki: 304l bakin karfe.
- Bas: Jan karfe; porter (HV / LV).
- M: Tubumpiram ™ Fr3 ™, Ester na halitta (vg-100®), man kayan lambu.
- Guges / na'urori: Iska na tekuna; Gaggawa / na'urori tare da lambar ƙararrawa.
- Balves / Matruts: Matsin lamba mara jini; m radiators tare da bawuloli.
- Karewa: Vfi / VFI - xD (overcurrent); Taro masu alfarma (kiba); mai sauri / kwatsam matsi na ruwa.
- Kaya: Galayen radiators, galvanized radiators, nema 4/la 4 / 4x / 7 akwatin sarrafawa; Cts / pts; tilasta sanyaya kayan sanyaya.
- M: Imppepecation a kowace bukata; low amo (har zuwa 20 dba); Marine fenti; Sedish yin tsayayya.
- Wasu: Amorphous M Karfe, Dua Dua; yanayi har zuwa 14,850 fasl; narkar da saka idanu na gas.
Vii. Abvantbuwan amfãni na scotech na scotech naúrar transfersmers
1. M kari & daidaitawa
- Waka zuwa Mahalli (Marine / Hadarau / Altitus (har zuwa 14,850 Fasl), kuma ba haka ba,- {Haske (misali, Harmonic Loading).
- Zaɓuɓɓukan da yawa: Tankunan Bakin Karfe, 304l Bakin Karfe Windings, eco {1} oil})), da ƙananan ƙwararru), da ƙananan kayan aiki (20 dBA) ko ƙirar kayan aiki) ko ƙayyadaddun kayan aiki.
- Bushings sun dakatar da swambing don hadewar tsarin.
2. Yarda da aminci & aminci
- A tsananin hadu da Anissi / Ieee, CSA, IEC, EN DOST; Ul - ired don musayar duniya.
- Daidaitawa wanda ba {0 ba 0 {} irp, mai na Arc Flash ba, da aji na 1, Amincewa na 1, wanda ya saba da karbuwa na yanki.
3. Babban aiki da karkara
- Maimada madaidaiciya
- Tankuna na robawa (tsayayya da 15 psig) da epoxy {{1} {1 {{- ire-iren juriya.
- Tsarin Digiri na digiri 65 + Tsarin sanyaya-ruwa (radiators / Fans) tabbatar da tsayayyen aiki.
4. Aminci & Muhalli & Muhalli
- Sanye take da bawul din kwanciyar hankali, Buchholz Relays, da kuma na zaɓi VFI- XD (Karamin Kariya).
- ECO {{0} options options options:: Zaɓuɓɓuka Enter; Gwajin masana'anta yana haifar da gas fiye da ƙa'idodin masana'antu.
- Zabi karami {{0} 0} desig Tsarin aiki suna rage tasiri aiki.
5. Rigoroor Qc &
- 17 Pre {{{-} Tasirin bayarwa (secelctric, yana tashi, da sauransu) garanti da inganci.
- Ya yi daidai da tsararraki (iska / windar / hasken rana), masana'antu, ma'adinai, da sassan soja.
- Abubuwan da ke ɗauke da radiators, masu lalata radiators, da kuma kulawa mai hankali don kulawa mai sauƙi.
6. Ingantaccen karfi {{1} ceton & farashin farashi
- Haɗu da ƙarfi - uticitian matakan aiki (misali, doe); Amorphous cores a yanka babu {{3} en asarar cika da kashi 70%.
- Tsawo {{0 0
- Mataccen sanyi yana daidaita fitarwa bisa tsari, rage yawan amfani da makamashi aiki.
Viii. Abubuwa don la'akari lokacin zabar canjin naúrar
Sigogi na lantarki & buƙatun kaya
- Dace da karfin (tare da 10-20% fadada gefe na) zuwa jimlar / koneq. Tabbatar da HV / LV da Δ / Y Kanfigareshan.
- Zaɓi rashin daidaituwa a kowane tsarin gajere {{0} iyakokin da'ira; Zabi oltc ({{- uple gyaran wutar lantarki) ko NlC (offline).
- Daidai don nau'in kaya: K {{0 0.
Daidaitawa da muhalli
- Yi haƙuri da temp / laima; Select kan - olt modents (har zuwa 14,850 fasl) idan an buƙata.
- Or- cor 0 fannoni: Tankana na Bakin Karfe: Tankunan Karfe {{2} enu; Hadarin haɗari yana buƙatar aji 1, Disc 2.
- Low {{0} enise (20 dba na tilas) ga wuraren zama; semindishin ƙarfafa na da bangarorin girgizar kasa.
Aiki da Inganci
- Bin ka'idodin Doe / EU; Yi amfani da kwayar cutar / ruwan ja / jan ƙarfe don yanke asarar kuzari.
- Mataki na sanyaya don kaya: Onan (haske), Onaf /af (mai nauyi), {(babba {{0} damar).
- Ka fifita epoxy - enulated iska da tsawan ruwa (ba {{{- ma'adanan ma'adinai / ESTER / man kayan lambu).
Aminci & Yarda da Tabbatarwa
- Haɗu da Anis / IeEe / Kungiyar CSA / CSA; Ul {{{0} {topi
- Hada daidaitattun kariya (Verves Rarraba Bakuljo, Buchholz Relays); Add vfi - XD masu tallata allo idan ana buƙata.
- Guji kwastomomi; Zabi ECO -} iren ruwa don tarawa dokokin muhalli.
Shigarwa & Tabbatar da Tabbatarwa
- Girman sarari / iyakoki; Fita don Skid - ya sanya zane-zane idan aka kure.
- Tabbatar da bugun tsuntsaye; Bedtizeze mai amfani da masu radives da m radiators.
- Aara mai hankali kula (narkar da gas / fiber {0} {0 temp) don gyara tsare.
Jimlar kudin rayuwa
- Balaga na farko na farko (misali, murfin jan ƙarfe vs. tsawo {{3} na ajiyar ajalin lokaci).
- Lissafta ƙarfin aiki -} Fitar da kudaden farashin tsada; Zabi tsawo {{1} Abubuwan da aka gyara na rayuwa zuwa ƙananan kudaden tabbatarwa.
Aika Aikace-aikacen

